927 resultados para Image processing, computer-assisted
Resumo:
Purpose: The aim of this study was to evaluate the surface roughness of four packable composite resins, SureFil™ (Dentsply, Petrópolis, Rio de Janeiro, Brazil), Prodigy Condensable™ (Kerr Co., Orange, CA, USA), Filtek P60™ (3M do Brasil, São Paulo, Brazil), and ALERT® (Jeneric/Pentron, Inc., Wallingford, CT, USA) and one microhybrid composite resin (Filtek Z250™, 3M do Brasil) after polishing with four finishing systems. Materials and Methods: Twenty specimens were made of each material (5 mm in diameter and 4 mm high) and were analyzed with a profilometer (Perthometer® S8P, Perthen, Mahr, Germany) to measure the mean surface roughness (Ra). The specimens were then divided into four groups according to the polishing system: group 1 - Sof-Lex™ (3M do Brasil), group 2 - Enhance™ (Dentsply), group 3 - Composite Finishing Kit (KG Sorensen, Barueri, São Paulo, Brazil), and group 4 - Jiffy Polisher Cups® (Ultradent Products, Inc., South Jordan, UT, USA). The specimens were polished and then evaluated for Ra, and the data were subjected to analysis of variance, analysis of covariance, and Tukey's test (p = .05). Results: The mean Ra of SureFil polished with Sof-Lex was significantly lower than that of KG points. Prodigy Condensable polished with Enhance showed a significantly less rough surface than when polished with Sof-Lex. Filtek P60 did not exhibit a significant difference with the various polishing systems. For ALERT the lowest mean Ra was obtained with Sof-Lex and the highest mean Ra with KG points. Regarding Filtek Z250, polishing with KG and Jiffy points resulted in a significantly lower mean Ra than when polished with Enhance. Conclusions: Packable composite resins display variable roughness depending on the polishing system used; the Sof-Lex disks and Jiffy points resulted in the best Ra values for the majority of the materials tested.
Resumo:
This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.
Resumo:
Purpose: Spontaneous eye blink activity in the primary eye position and its relationship to age and gender were assessed using digital image processing techniques to quantify blink opening and closing time. Methods: One hundred-and-eighty healthy volunteers (90 males and 90 females), divided into the age groups 0-3, 4-12, 13-20, 21-40, 41-60 and ≥60 years old, were evaluated prospectively. They were videotaped digitally in a standard setting and the images were transferred to a personal computer (Macintosh 400) and processed with the iMovie software. Blink opening and closing time were measured at 30 frames/second. The data were then subjected to statistical analysis. Results: The closing time was significantly longer than the opening time for all ages and both genders. Elderly individuals (≥41 years old) and women had significantly longer closing times. Conclusion: Image processing techniques made possible the observation of differences in spontaneous eye blink opening and closing time in relation to age and gender. Copyright © 2005 Taylor & Francis LLC.
Resumo:
Objective: The purpose of this study was to histologically analyze the influence of bioactive glass and/or a calcium sulfate barrier on bone healing in surgically created defects in rat tibias. Material and methods: Sixty-four rats were divided into 4 groups: C (control), CS (calcium sulfate), BG (bioactive glass), and BG/CS (bioactive glass/calcium sulfate). A surgical defect was created in the tibia of each animal. In Group CS, a calcium sulfate barrier was placed to cover the defect. In Group BG the defect was filled with bioactive glass. In Group BG/CS, it was filled with bioactive glass and protected by a barrier of calcium sulfate. Animals were sacrificed at 10 or 30 days post-operative. The formation of new bone in the cortical area of the defect was evaluated histomorphometrically. Results: At 10 days post-operative, Group C presented significantly more bone formation than Groups CS, BG, or BG/CS. No statistically significant differences were found between the experimental groups. At 30 days post-operative, Group C demonstrated significantly more bone formation than the experimental groups. Groups CS and BG/CS showed significantly more bone formation than Group BG. No statistically significant differences were found between Group CS and BG/CS. Conclusions: (a) the control groups had significantly more bone formation than the experimental groups; (b) at 10 days post-operative, no significant differences were found between any of the experimental groups; and (c) at 30 days post-operative, the groups with a calcium sulfate barrier had significantly more bone formation than the group that used bioactive glass only. Copyright © Blackwell Munksgaard 2005.
Resumo:
The purpose of this study was to evaluate the effectiveness of subgingival application of Carisolv™ gel as an adjunctive therapy to scaling and root planing (SRP) on calculus removal compared to conventional instrumentation. Forty-five teeth requiring extraction due to severe periodontal disease were randomized to the following treatments: 1) SRP alone; 2) placebo gel + SRP; 3) Carisolv™ gel + SRP. Either test or placebo gel was applied subgingivally for 1 min and then the root were instrumented until a smooth and calculus-free surface was achieved. Instrumentation time and the number of strokes required were recorded. After extraction, the efficacy of root surface instrumentation was measured by percentage of remaining calculus. There was no statistically significant difference (p>0.05) between the treatment groups regarding either time required for instrumentation or the percentage of residual calculus. The subgingival application of Carisolv™ gel prior to SRP did not provide any additional benefit to root instrumentation compared to scaling and root planing alone.
Resumo:
The suprachiasmatic nucleus, an essential diencephalic component of the circadian timing system, plays a role in the generation and modulation of behavioral and neuroendocrine rhythms in mammals. Its cytoarchitecture, neurochemical and hodological characteristics have been investigated in various mammalian species, particularly in rodents. In most species, two subdivisions, based on these aspects and considered to reflect functional specialization within the nucleus, can be recognized. Many studies reveal a typical dense innervation by serotonergic fibers in this nucleus, mainly in the ventromedial area, overlapping the retinal afferents. However, a different pattern occurs in certain animals, which lead us to investigate the distribution of serotonergic afferents in the suprachiasmatic nucleus of the Capuchin monkey, Cebus apella, compared to the marmoset, Callithrix jacchus, and two Rattus norvegicus lines (Long Evans and Wistar), and to reported findings for other mammalian species. Our morphometric data show the volume and length of the suprachiasmatic nucleus along the rostrocaudal axis to be greatest in C. apella > C. jacchus > Long Evans ≥ Wistar rats, in agreement with their body sizes. In C. apella, however, the serotonergic terminals occupy only some 10% of the nucleus' area, less than the 25% seen in the marmoset and rats. The distribution of the serotonergic fibers in C. apella does not follow the characteristic ventral organization pattern seen in the rodents. These findings raise questions concerning the intrinsic organization of the nucleus, as well as regarding the functional relationship between serotonergic input and retinal afferents in this diurnal species. © 2007 Elsevier B.V. All rights reserved.
Resumo:
AIM: To investigate the relationship between divine proportion and facial esthetics in frontal photographs as well as whether any of the 4 ratios for manipulation provide more favorable facial esthetics. MATERIAL AND METHODS: The sample comprised 20 frontal photographs of Caucasian individuals (11 males and 9 females). The photographs were digitized and stored on a compact disk. A photometric analysis was created with 7 facial segments that were measured on Image Tool software and 4 ratios between 2 facial segments calculated using Microsoft Excel. This manipulation led to 5 different photographs of the same individual: one photograph with no manipulation and the others with 1 of the ratios manipulated in the Deformer 2.0 to very close or equal to 1.618. Thereafter, the 5 photographs of all individuals were evaluated by 12 examiners. The examiners selected those photographs that were esthetically more pleasant. CONCLUSION: After evaluation, a chi-square test revealed a relationship between divine proportion and facial esthetics. Among the ratios selected, R1 and R2 provided more favorable facial esthetics.
Resumo:
OBJECTIVE: To analyze the clinical behavior of 2 pit and fissure sealants through clinical/computerized evaluation. METHOD AND MATERIALS: Occlusal sealants were placed on maxillary and mandibular first and second premolars according to a split-mouth design. All premolars were sealed with either Concise (3M Espe) or Prisma Shield (Caulk/Dentsply) sealant agents. A hematoxylin-based staining solution was applied on the occlusal surface 7 days, 18 months, 36 months, and 11 years after occlusal sealing to allow checking of the sealant material on the surface. At each analysis time all occlusal surfaces were photographed, and the photographs corresponding to each time period were analyzed with SigmaScan 4.0 Software. The alterations of the sealed area of each sealant were analyzed with the software and recorded. Next, the measurements of the areas were tabulated and analyzed according to each period. Analysis of variance (ANOVA), with parts subdivided into time, and the t test, with a significance level of 5%, were used. RESULTS: The greatest sealed area was maintained by the sealant Concise. However, over the course of 11 years, all sealants began to show the same level of alteration in sealed area. CONCLUSION: The sealing materials showed alteration in sealed area over time, but they were efficient in controlling caries lesion formation on premolar pits and fissures.
Resumo:
Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.
Resumo:
Purpose: Symmetry is one of the factors that contributes to facial harmony, and in oral rehabilitation it determines the success of esthetic treatment. Therefore, the aim of the present study was to analyze the axial symmetry between the bipupillar midline and maxillary central incisors midline of 102 dental students (both genders) distributed across five Brazilian dental schools. Materials and Methods: Students with no teeth missing and who had never been subjected to any dental treatment were selected. Photographs were taken with a Dental Eye III camera with a 100-mm macro objective and ratio of 1 : 10 from natural size, recorded on an Ektachrome ASA/ISO 100 film. The images were developed and applied to Microsoft Office Power Point 2007 software. The results were analyzed by analysis of variance and Student's t-test (= 0.05). Results: There was no significant correlation between bipupillar midline and the maxillary dental midline, irrespective of gender. Conclusion: No significant coincidence was observed between the interpupillary and dental midline. However, the interpupillar distance and its relationship with other anatomic structures may be used as a reference in treatment, but measurements must be assessed individually. CLINICAL SIGNIFICANCE Anatomic measurements and facial proportions can be helpful during the planning of esthetic oral rehabilitation. © 2009 Wiley Periodicals, Inc.
Resumo:
The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.
Resumo:
The treatment of Class II adult individuals with mandibular deficiency has been the combination of orthodontic treatment and orthognathic surgery. Therefore, a study was conducted in which cephalometric analysis was used to evaluate the influence of dentoalveolar decompensation in Class II patients submitted to orthodontic and surgical treatment for mandibular advancement, by bilateral osteotomy of the mandibular ramus. A sample of 15 leukoderma adult female patients were selected and three cephalometric radiographs of each patient, taken before the orthodontic treatment, before surgery and after at least 6 months postoperatively, were analyzed in a total of 45 roentgenograms. The tracings were made by the manual method and the points were digitalized using software. The results showed that values of SNB increased from 75.6 to 78.6°. The measures BNP and PGNP were reduced from -12.7 to -7.7 mm and -12.7 to -6.6 mm, respectively. For ANB there was a reduction of 3.23° (from 8.1° to 4.9°). Likewise, the values of AOBO were diminished by 6.3 mm (from 7.6 to 1.3 mm), and in the values of OJ there was a reduction of 5.7 mm (from 9 to 3.3 mm). It was concluded that the pre-surgical orthodontic treatment promoted minimal and variable dental and skeletal changes in the final result. The surgical treatment caused significant skeletal changes, especially in the measurements related to the mandible (SNB, BNP, PGNP and SNPM) or indirectly to it (ANB, AOBO and OJ).
Resumo:
Melasma is a common acquired symmetrical hypermelanosis characterized by irregular light- to dark-brown macules on sun-exposed skin areas. The literature shows few studies on its physiopathogeny. However, changes in α-melanocyte stimulating hormone (α-MSH) secretion and melanocortin-1 receptor (MC1-R) expression may play a role to trigger this condition. Biopsies were taken from both melasma skin and adjacent perilesional normal skin of 44 patients. The biopsies were submitted for hematoxylin and eosin and Fontana-Masson staining and immunohistochemistry with Melan-A, α-MSH, and MC1-R, and processed for transmission electron microscopy. In some cases, they were submitted to MC1-R gene expression analysis by real-time polymerase chain reaction. Increased lymphohistiocytic infiltrate and solar elastosis, higher epidermal melanin were observed in melasma skin. Electron microscopy revealed a greater number of mature melanosomes in keratinocytes and melanocytes, and more prominent cytoplasmic organelles in melasma skin. There was no difference in melanocyte number between areas. However, melanocytes were larger and more dendritic in melasma skin. Immunohistochemistry with α-MSH and MC1-R showed significant labeling in melasmic epidermis but MC1-R messenger ribonucleic acid (RNAm) did not show significant quantitative difference between melasma and normal skin. © 2010 by Lippincott Williams & Wilkins.
Resumo:
Background: Actinic cheilitis (AC) is a premalignant condition intimately related to exposure of the lips to sun rays. Aim: The objective of this study was to evaluate the elastic and collagen fibers in the lamina propria of AC. The degree of epithelial atypia was correlated with the quantity of elastic and collagen fibers. Materials and Methods: Fifty-one cases were investigated. One slide was stained with hematoxylin-eosin for the evaluation of atypia, the second was stained with Weigert′s resorcin-fuchsin for the assessment of elastic fibers, and the third slide was stained with Mallory′s trichrome for the analysis of collagen fibers. Results: Ordinal logistic regression analysis revealed a significant correlation between the presence of atypia and collagen fibers (P<0.05). Conclusions: It was concluded that there seems to be a reduction in the quantity of collagen fibers in cases of moderate and severe atypia. No correlation was observed between the degradation of elastic system fibers and the grade of dysplasia.