Resumo:

Radium was radiochemically separated from natural thorium. Thin Ra-228 ->beta Ac-228 sources were prepared and exposed to mica fission track detectors, and measured by an HPGe gamma-ray detector. The beta-delayed fission events of Ac-228 were observed and its beta-delayed fission probability was found to be (5 +/- 2)x10(-12).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了一个峰保持电路。该电路适用于silicon strip,Si(Li),CdZn Te and CsI等探测器,实现采样-保持功能。已成功进行了基于CMOSFET的采样-保持电路的设计和仿真,通过使用Proteus的PSPICE仿真器和BSIMV3.3模型参数完成了电路性能的仿真。同时,实现了采样时间可在60ns到4.44s范围内进行选择,该电路具有较好的线性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

为了在CSRm的电子冷却器上进行辐射复合以及双电子复合实验,需要探测能量小于4MeV/u的离子,因此设计了新的置于超高真空环境的CsI(Tl)闪烁探测器,探测器采用的光电倍增管为R7525(Hamamatsu)。介绍了新闪烁探测器的结构,并对其进行了性能测试。测试结果表明,该探测器对高、低能离子均有良好的响应,探测器的信号十分明显。探测器的最高计数率可以达到106ions/s,并且探测器附近的真空度可达10-10Pa量级,能够满足辐射复合与双电子复合实验以及储存环对真空的要求,为今后在CSRm上进行复合实验打下了良好的基础。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

对闪烁光在晶体内的传输以及光电子倍增过程进行了建模,基于GEANT4软件包对CsI(T1)闪烁体探测器进行了蒙特卡罗模拟,得到了不同形状、尺寸和包装的CsI(Tl)晶体测量γ射线的能谱。对比模拟和测试结果,两者得到了很好的符合,从而验证了模拟参数的合理性和可靠性。该模拟程序的建立为闪烁体探测器的设计提供了更精确的开发工具。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

探测器位置分辨能力的高低是实现γ成像的一个重要指标.Segmented HPGe平面型位置灵敏探测器能够很好地给出γ射线与探测器晶体相互作用的作用点位置信息.利用由这种探测器组成的探测器阵列对~(22)Na标准源进行了γ成像实验.结果能够区分出标准源两个不同的摆放位置的细微差别,并与实际情况符合得很好.从而检验了Segmented HPGe平面型位置灵敏探测器的位置分辨能力.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Yields, correlation shapes, and mean transverse momenta p(T) of charged particles associated with intermediate-to high-p(T) trigger particles (2.5 < p(T) < 10 GeV/c) in d + Au and Au + Au collisions at root s(NN) = 200 GeV are presented. For associated particles at higher p(T) greater than or similar to 2.5 GeV/c, narrow correlation peaks are seen in d + Au and Au + Au, indicating that the main production mechanism is jet fragmentation. At lower associated particle pT < 2 GeV/c, a large enhancement of the near- (Delta phi similar to 0) and away-side (Delta phi similar to pi) associated yields is found, together with a strong broadening of the away-side azimuthal distributions in Au + Au collisions compared to d + Au measurements, suggesting that other particle production mechanisms play a role. This is further supported by the observed significant softening of the away-side associated particle yield distribution at Delta phi similar to pi in central Au + Au collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of pi(+)pi(-)pi(+)pi(-) photonuclear production in ultraperipheral Au-Au collisions at root s(NN) = 200 GeV from the STAR experiment. The pi(+)pi(-)pi(+)pi(-) final states are observed at low transverse momentum and are accompanied by mutual nuclear excitation of the beam particles. The strong enhancement of the production cross section at low transverse momentum is consistent with coherent photoproduction. The pi(+)pi(-)pi(+)pi(-) invariant mass spectrum of the coherent events exhibits a broad peak around 1540 +/- 40 MeV/c(2) with a width of 570 +/- 60 MeV/c(2), in agreement with the photoproduction data for the rho(0)(1700). We do not observe a corresponding peak in the pi(+)pi(-) final state and measure an upper limit for the ratio of the branching fractions of the rho(0)(1700) to pi(+)pi(-) and pi(+)pi(-)pi(+)pi(-) of 2.5% at 90% confidence level. The ratio of rho(0)(1700) and rho(0)(770) coherent production cross sections is measured to be 13.4 +/- 0.8(stat.) +/- 4.4(syst.)%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable Cl controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe) The detector has been successfully used in an experiment to measure the masses of the N approximate to Z approximate to 33 nuclides near the proton drip-line Of particular interest is the mass of As-65 A maximum detection efficiency of 70% and a time resolution of 118 +/- 8 Ps (FWHM) have been achieved in the experiment The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied The potential of APH for Z identification has been discussed (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

描述了1个8×8单元CsI(Tl)探测阵列的结构和工作原理。探测阵列的每个单元是由1块前表面21 mm×21 mm、后表面23.1 mm×23.1 mm、高50 mm的CsI(Tl)棱台、1块光导和光电倍增管组成。在兰州放射性次级束流线(RIBLL)上对探测阵列进行测试,得到探测阵列对30 MeV质子的能量分辨可达2.7%,对170 MeV7Be可达1.5%,可很好地用于放射性束物理实验中带电粒子的鉴别。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

针对高流强粒子束与绝缘毛细管相互作用的特点,设计制作了一套64通道一维位置灵敏电流分布探测器及其配套的数据获取系统,该探测器可分辨最小直径为1mm的束斑,通过数据获取系统可实现可视化自动数据采集。用2nA和200—2000eV电子对探测器进行了定标,并用10μA和2000eV的电子束穿越锥形毛细管后的出射电子,对探测器及数据获取系统进行测试,获得了出射粒子的位置分布谱及能量信息。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The resolution and the summing characteristics of an EXOGAM segmented Clover germanium detector has been studied for use it in gamma spectroscopic experiments. The measurements have been performed with standard radioactive sources of Eu-152, Ba-133 and beta-delayed gamma-rays from Ir-176 decay. The data analytic results, realized by software, are presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with different gas mixtures. The results indicate that an energy resolution 30% in single and double mode can be obtained. The existence of an optimum energy resolution is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports that the K x-ray spectra of the thin target 47Ag, 48Cd, 49In and 50Sn were measured by an HPGe semi-conductor detector in collisions with 84.5 MeV 6C4+ ions. Our experiment revealed the Kα x-ray energy shifts were not obvious and the Kβ1 x-ray energy shifts were about 90∼110 eV. The simple model of Burch et al has been previously used to calculate the K x-ray energy shifts due to an additional vacancy in 2p orbit. The present work extends the model of Burch to calculate the x-ray energy shifts of multiple ionized atoms induced by heavy ions with kinetic energy of MeV/u. In addition to our experimental results, many other experimental results are compared with the calculated values by using the model.