938 resultados para Geiger-Muller detector


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In present paper, a new Micromegas detector is developed, and its time and energy signals are obtained in the figure form. The rising time of fast time signal is less than 2 ns due to the very fast collection of avalanche electrons, and the rising time of the energy pulse is about 100 ns, which is corresponding to the total collecting time of the electrons and ions in the avalanche process. The counter plateau, energy resolution and the gas gains of the detector have been compared with other groups' experimental results and the Garfield simulation result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics LanzhoU Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp -> pp + phi(-> K+K-), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed phi are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp -> pp + K+K- as background. The geometry coverage of FTD for phi events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of the in-beam efficiency calibration of Neutron Detector Array of Peking University using N-17 and C-16 beams was introduced in this paper. The efficiency of neutron wall and ball are comparable to the foreign similar devices and neutrons can be detected from low to high energies in high efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new non-linear comparison method of charge-division readout scheme is conceived and the first design of a multi-hit two-dimensional position-sensitive energy spectrum Si(Au) surface barrier detector with a continuous sensitive area is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a batch file which describes the detailed structure and the corresponding physical process of Micro-Mesh Gaseous Structure (Micromegas) detector, the macro commands and the control structures based on the Garfield program has been developed. And using the Garfield program controlled by this batch file, the detector's gain and spatial resolution have been investigated under different conditions. These results obtained by the simulation program not only exhibit the influences of the mesh and drift voltage, the mixture gas proportion, the distance between the mesh cathode and the printed circuit board readout anode, and the Lines Per Inch of the mesh cathode on the gain and spatial resolution of the detector, but also are very important to optimize the design, shorten the experimental period, and save cost during the detector development. Additionally, they also indicate that the Garfield program is a powerful tool for the Micromegas detector design and optimization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the performance of a EXOGAM-Segmented-Clover with 16 segments as a Compton polarimeter to measure the linear polarization of gamma rays. The polarization sensitivity of the Clover detector has been measured at the energy of 1332keV through the coincidence measurements of cascade gamma-rays from Co-60. Experimental values were in good accord with our expectation.We have investigated the performance of a EXOGAM-Segmented-Clover with 16 segments as a Compton polarimeter to measure the linear polarization of gamma rays. The polarization sensitivity of the Clover detector has been measured at the energy of 1332keV through the coincidence measurements of cascade gamma-rays from Co-60. Experimental values were in good accord with our expectation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The temperature dependences of the light output of CsI(Tl) crystal grown at IMP and of the gain of the Hamamatsu S8664-1010 avalanche photodiode (APD) have been investigated systematically. The light output of the CsI(Tl) crystal increases with temperature by 0.67%/degrees C in the region from -2 degrees C to 8 degrees C, and by 0.33%/degrees C in the region from 8 degrees C to 25 degrees C, while the gain of the tested APD decreases by -3.68%/degrees C (working voltage 400V) on average in the room temperature range. The best energy resolution 5.1% of the CsI(Tl) with APD was obtained for the 662keV gamma ray from Cs-137 radiation source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The light calibration system is one of the key components of Neutron Wall detector. It is used to calibrate the electronics and to monitor the long-term stability of the detector modules. With the detaile investigations, a calibration system with high-power LED (3W) driven by the fast pulses has been carried out. It is also tested together with the detector module of the Neutron Wall and the result of the preliminary calibration demonstrates that it fulfills the needs. It's a new design proposal to the light calibration system of the fast scintillator detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了一个峰保持电路。该电路适用于silicon strip,Si(Li),CdZn Te and CsI等探测器,实现采样-保持功能。已成功进行了基于CMOSFET的采样-保持电路的设计和仿真,通过使用Proteus的PSPICE仿真器和BSIMV3.3模型参数完成了电路性能的仿真。同时,实现了采样时间可在60ns到4.44s范围内进行选择,该电路具有较好的线性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

为了在CSRm的电子冷却器上进行辐射复合以及双电子复合实验,需要探测能量小于4MeV/u的离子,因此设计了新的置于超高真空环境的CsI(Tl)闪烁探测器,探测器采用的光电倍增管为R7525(Hamamatsu)。介绍了新闪烁探测器的结构,并对其进行了性能测试。测试结果表明,该探测器对高、低能离子均有良好的响应,探测器的信号十分明显。探测器的最高计数率可以达到106ions/s,并且探测器附近的真空度可达10-10Pa量级,能够满足辐射复合与双电子复合实验以及储存环对真空的要求,为今后在CSRm上进行复合实验打下了良好的基础。