818 resultados para Fire insurance claims adjusters.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light gauge steel frame (LSF) structures are increasingly used in commercial and residential buildings because of their non-combustibility, dimensional stability and ease of installation. A common application is in floor-ceiling systems. The LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire-rated floor-ceiling assemblies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite floor-ceiling system has been developed to provide higher fire rating. But its increased fire rating could not be determined using the currently available design methods. Therefore a research project was conducted to investigate its structural and fire resistance behaviour under standard fire conditions. This paper presents the results of full scale experimental investigations into the structural and fire behaviour of the new LSF floor system protected by the composite ceiling unit. Both the conventional and the new floor systems were tested under structural and fire loads. It demonstrates the improvements provided by the new composite panel system in comparison to conventional floor systems. Numerical studies were also undertaken using the finite element program ABAQUS. Measured temperature profiles of floors were used in the numerical analyses and their results were compared with fire test results. Tests and numerical studies provided a good understanding of the fire behaviour of the LSF floor-ceiling systems and confirmed the superior performance of the new composite system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire design is an essential part of the overall design procedure of structural steel members and systems. Conventionally, increased fire rating is provided simply by adding more plasterboards to Light gauge Steel Frame (LSF) stud walls, which is inefficient. However, recently Kolarkar & Mahendran (2008) developed a new composite wall panel system, where the insulation was located externally between the plasterboards on both sides of the steel wall frame. Numerical and experimental studies were undertaken to investigate the structural and fire performance of LSF walls using the new composite panels under axial compression. This paper presents the details of the numerical studies of the new LSF walls and the results. It also includes brief details of the experimental studies. Experimental and numerical results were compared for the purpose of validating the developed numerical model. The paper also describes the structural and fire performance of the new LSF wall system in comparison to traditional wall systems using cavity insulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If current population and accommodation trends continue, Australian cities will, in the future, have noticeable numbers of apartment buildings over 60 storeys high. With an aging population it follows that a significant proportion of those occupying these buildings will be senior citizens, many of whom will have some form of disability. For these occupants a fire emergency in a high rise building presents a serious problem. Currently lifts cannot be used for evacuation and going down 60 storeys in a fire isolated staircase would be physically impossible for many. Therefore, for many, the temptation to remain in one’s unit will be very strong. With an awareness of this behaviour trend in older residents, many researchers have, in recent years, explored the possible wider use of lifts in a fire emergency. So far the use of lifts for evacuation has been approved for a small number of buildings but wide acceptance of this solution is still to be achieved. This paper concludes that even in high-rise apartment buildings where lifts are approved for evacuation, architects should design the building with alternative evacuation routes and provide suitable safe refuge areas for those who cannot use the stairs when the lifts are unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The insurance industry discharges a critical role in the Australian economy and is a significant part of the Australian financial services market. The industry relies upon intermediaries, the principal types being brokers and agents, to promote, arrange and distribute their products and services in the market. The pivotal role that they play in this context and sensitivities associated with the consumer oriented products, such as house and contents insurance, has ensured close regulatory attention. Of particular importance was the passage of the Insurance (Agents and Brokers) Act 1984 (Cth), a comprehensive attempt to address the responsibilities of intermediaries as well as particular problem areas associated with the handling of money. However, with the introduction of financial services and market reform early in the new millennium this insurance intermediary specific regulatory approach was abandoned in favour of a market-wide strategy; that is, market reform was based upon across-the-board licensing, disclosure, conduct and fairness standards, and all financial products and services are now regulated at a generic level under Ch 7 of the Corporations Act 2001 (Cth). This article briefly explores the categories of insurance intermediaries and the relevant distinctions between them but focuses mainly upon the regulatory context in which they operate. This context transcends a strictly legal framework as the regulatory body, the Australian Securities and Investments Commission (ASIC), has sought to inform and guide the market through Policy Statements and Regulatory Guides. The usefulness of these guides as an adjunct to the legislation in explaining the scope and operation of regulatory framework is examined. In addition, the article looks at the self-regulatory and dispute resolution practices in this area and their impact. In conclusion an assessment of this across-the-board regulatory regime is advanced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Cook v Cook the Australian High Court held that the standard of reasonable care owed by a learner driver to an instructor, conscious of the driver’s lack of experience, was lower than that owed to other passengers and road users. Recently, in Imbree v McNeilly, the High Court declined to follow this principle, concluding that the driver’s status or relationship with the claimant should no longer influence or alter the standard of care owed. The decision therefore provides an opportunity to re-examine the rationale and policy behind current jurisprudence governing the standard of care owed by learner drivers. In doing so, this article considers the principles relevant to determining the standard and Imbree’s implications for other areas of tort law and claimant v defendant relationships. It argues that Imbree was influenced by changing judicial perceptions concerning the vulnerability of driving instructors and the relevance of insurance to tortious liability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In larger developments there is potential for construction cranes to encroach into the airspace of neighbouring properties. To resolve issues of this nature, a statutory right of user may be sought under s 180 of the Property Law Act 1974 (Qld). Section 180 allows the court to impose a statutory right of user on servient land where it is reasonably necessary in the interests of effective use in any reasonable manner of the dominant land. Such an order will not be made unless the court is satisfied that it is consistent with public interest, the owner of the servient land can be adequately recompensed for any loss or disadvantage which may be suffered from the imposition and the owner of the servient land has refused unreasonably to agree to accept the imposition of that obligation. In applying the statutory provision, a key practical concern for legal advisers will be the basis for assessment of compensation. A recent decision of the Queensland Supreme Court (Douglas J) provides guidance concerning matters relevant to this assessment. The decision is Lang Parade Pty Ltd v Peluso [2005] QSC 112.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a resilience enhancing practice, business continuity management (BCM) can play an important role in aiding preparation of the insurance industry for coping with the losses incurred by major discontinuity incidents: regardless of cause. Acknowledging the increasing frequency of unpredictable man-made disasters and natural catastrophes, the insurance industry would benefit from examining and implementing, where suitable, key elements of BCM. Such strategic decisions would assist insurers and re-insurers collectively to enhance mutual capability to respond to, and recover from, the impact of significant losses. This paper presents a comparison of opinions about BCM practitioners in both retail and re-insurance companies on the importance of generic continuity practices with actual levels of BCM practice across the two industry groups in Southeast Asia. It suggests means by which multi-lateral cooperation across Asian economies and between retail and re-insurance market segments might enhance the viability of the insurance industry in the face of increased stress from major natural and socio-technical hazards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent floods in Queensland and elsewhere in Australia as well as the recent earthquakes in New Zealand have again given rise to very significant uninsured losses. This article looks at the issue of cover protection against catastrophes such as floods and earthquakes affecting home buildings and contents insurance and the standard cover provisions of the Insurance Contracts Act 1984 (Cth). It points also to the possibility of a national scheme to cover natural disasters including floods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel stud walls are a major component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of stud wall systems while past research showed contradicting results, for example, about the benefits of cavity insulation. This research was therefore conducted to improve the knowledge and understanding of the structural and thermal performance of cold-formed steel stud wall systems (both load bearing and non-load bearing) under fire conditions and to develop new improved stud wall systems including reliable and simple methods to predict their fire resistance rating. Full scale fire tests of cold-formed steel stud wall systems formed the basis of this research. This research proposed an innovative LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating. Hence fire tests included both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. A propane fired gas furnace was specially designed and constructed first. The furnace was designed to deliver heat in accordance with the standard time temperature curve as proposed by AS 1530.4 (SA, 2005). A compression loading frame capable of loading the individual studs of a full scale steel stud wall system was also designed and built for the load-bearing tests. Fire tests included comprehensive time-temperature measurements across the thickness and along the length of all the specimens using K type thermocouples. They also included the measurements of load-deformation characteristics of stud walls until failure. The first phase of fire tests included 15 small scale fire tests of gypsum plasterboards, and composite panels using different types of insulating material of varying thickness and density. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effect of interfaces between adjacent plasterboards on the thermal performance. Effects of insulations such as glass fibre, rock fibre and cellulose fibre were also determined while the tests provided important data relating to the temperature at which the fall off of external plasterboards occurred. In the second phase, nine small scale non-load bearing wall specimens were tested to investigate the thermal performance of conventional and innovative steel stud wall systems. Effects of single and multiple layers of plasterboards with and without vertical joints were investigated. The new composite panels were seen to offer greater thermal protection to the studs in comparison to the conventional panels. In the third phase of fire tests, nine full scale load bearing wall specimens were tested to study the thermal and structural performance of the load bearing wall assemblies. A full scale test was also conducted at ambient temperature. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided good explanations and supporting research data to overcome the incorrect industry assumptions about cavity insulation. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of stud walls and increased their fire resistance rating significantly. Hence this research recommends the use of the new composite panel system for cold-formed LSF walls. This research also included steady state tensile tests at ambient and elevated temperatures to address the lack of reliable mechanical properties for high grade cold-formed steels at elevated temperatures. Suitable predictive equations were developed for calculating the yield strength and elastic modulus at elevated temperatures. In summary, this research has developed comprehensive experimental thermal and structural performance data for both the conventional and the proposed non-load bearing and load bearing stud wall systems under fire conditions. Idealized hot flange temperature profiles have been developed for non-insulated, cavity insulated and externally insulated load bearing wall models along with suitable equations for predicting their failure times. A graphical method has also been proposed to predict the failure times (fire rating) of non-load bearing and load bearing walls under different load ratios. The results from this research are useful to both fire researchers and engineers working in this field. Most importantly, this research has significantly improved the knowledge and understanding of cold-formed LSF walls under fire conditions, and developed an innovative LSF wall system with increased fire rating. It has clearly demonstrated the detrimental effects of using cavity insulation, and has paved the way for Australian building industries to develop new wall panels with increased fire rating for commercial applications worldwide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The question whether the loss of chance of a better medical outcome in cases of medical negligence should be recognised as actionable damage is ‘a question which has divided courts and commentators throughout the common law world.’ In April 2010, the High Court handed down its anticipated decision in the case of Tabet (by her Tutor Sheiban) v Gett (2010) 240 CLR 537. The issue considered by the court was whether the appellant could claim in negligence for the loss of a chance of a better medical outcome. This issue had not been considered by the High Court previously, the most relevant cases being Rufo v Hosking (2004) 61 NSWLR 678 and Gavalas v Singh (2001) 3 VLR 404. Claiming for a loss of chance in a personal injury action raises questions as to recognised damage and causation, and the members of the High Court considered both of these.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines, from both within and outside the context of compulsory third party motor vehicle insurance, the different academic and judicial perspectives regarding the relevance of insurance to the imposition of negligence liability via the formulation of legal principle. In particular, the utility of insurance in setting the standard of care held owing by a learner driver to an instructor in Imbree v McNeilly is analysed and the implications of this High Court decision, in light of current jurisprudential argument and for other principles of negligence liability, namely claimant vulnerability, are considered. It concludes that ultimately one’s stance as to the relevance, or otherwise, of insurance to the development of the common law of negligence will be predominately influenced by normative views of torts’ function as an instrument of corrective or distributive justice.