Improvements to the fire performance of light gauge steel floor systems


Autoria(s): Baleshan, Balachandren; Mahendran, Mahen
Data(s)

03/11/2010

Resumo

Light gauge steel frame (LSF) structures are increasingly used in commercial and residential buildings because of their non-combustibility, dimensional stability and ease of installation. A common application is in floor-ceiling systems. The LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire-rated floor-ceiling assemblies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite floor-ceiling system has been developed to provide higher fire rating. But its increased fire rating could not be determined using the currently available design methods. Therefore a research project was conducted to investigate its structural and fire resistance behaviour under standard fire conditions. This paper presents the results of full scale experimental investigations into the structural and fire behaviour of the new LSF floor system protected by the composite ceiling unit. Both the conventional and the new floor systems were tested under structural and fire loads. It demonstrates the improvements provided by the new composite panel system in comparison to conventional floor systems. Numerical studies were also undertaken using the finite element program ABAQUS. Measured temperature profiles of floors were used in the numerical analyses and their results were compared with fire test results. Tests and numerical studies provided a good understanding of the fire behaviour of the LSF floor-ceiling systems and confirmed the superior performance of the new composite system.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/32584/

Publicador

Wei-Wen Yu Center for Cold-Formed Steel Structures

Relação

http://eprints.qut.edu.au/32584/1/c32584.pdf

http://www.ccfssonline.org/cont_ed/intnl_speciality%20updated.html

Baleshan, Balachandren & Mahendran, Mahen (2010) Improvements to the fire performance of light gauge steel floor systems. In Proceedings of the 20th International Specialty Conference on Cold-Formed Steel Structures, Wei-Wen Yu Center for Cold-Formed Steel Structures, St. Louis, Missouri.

http://purl.org/au-research/grants/ARC/DP0986575

Direitos

Copyright 2010 [please consult the authors]

Fonte

Faculty of Built Environment and Engineering; School of Urban Development

Palavras-Chave #090506 Structural Engineering #Cold-formed steel #Fire rating #LSF Floors
Tipo