946 resultados para Fair value measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Grinding is an advanced machining process for the manufacturing of valuable complex and accurate parts for high added value sectors such as aerospace, wind generation, etc. Due to the extremely severe conditions inside grinding machines, critical process variables such as part surface finish or grinding wheel wear cannot be easily and cheaply measured on-line. In this paper a virtual sensor for on-line monitoring of those variables is presented. The sensor is based on the modelling ability of Artificial Neural Networks (ANNs) for stochastic and non-linear processes such as grinding; the selected architecture is the Layer-Recurrent neural network. The sensor makes use of the relation between the variables to be measured and power consumption in the wheel spindle, which can be easily measured. A sensor calibration methodology is presented, and the levels of error that can be expected are discussed. Validation of the new sensor is carried out by comparing the sensor's results with actual measurements carried out in an industrial grinding machine. Results show excellent estimation performance for both wheel wear and surface roughness. In the case of wheel wear, the absolute error is within the range of microns (average value 32 mu m). In the case of surface finish, the absolute error is well below R-a 1 mu m (average value 0.32 mu m). The present approach can be easily generalized to other grinding operations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Saturated sands particularly at low relative density commonly exhibit rises in excess pore pressure when subjected to earthquake loading. The excess pore pressure can approach a maximum value, limited by the initial vertical effective stress. After the completion of earthquake shaking, these excess pore pressures dissipate according to the consolidation equation, which can be solved to produce a Fourier series solution. It will be shown by manipulation of this Fourier series that excess pore pressure traces provide a method for back-calculation of coefficient of consolidation Cv. This method is validated against dissipation curves generated using known values of C v and seen to be more accurate in the middle of the layer. The method is then applied to data recorded in centrifuge tests to evaluate Cv throughout the reconsolidation process following liquefaction conditions. C v is seen to fit better as a function of excess pore pressure ratio than effective stress for the stress levels considered. For the soil investigated, Cv is about three times smaller at excess pore pressure ratio of 0.9 compared to excess pore pressure ratio of 0. Copyright © 1996-2011 ASTM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose for which this study was intended wasto compare nutritive value among the farmed Vannamei, sea Green Tiger and Banana shrimps native to the PersianGulf. To provide the samples of farmed shrimps at the end of the farming season (Oct. 23rd through Nov. 22nd of 2011), we chosen one farm of the Holleh Shrimp Farming, from which 100 shrimps were randomly selected. From among these 100 shrimps, 3 to 5 ones were taken to conduct an analysis upon. Further, to obtain the Banana and Green Tiger shrimps sampling was done at the fishing season (July 23rd through Aug. 22rd of 2011) at Halileh Fishing Wharf located in Bushehr Fishing Harbor and also Bandar Abbas Wharf. The samples obtained were immediately kept in the ice powder. After some biometric tasks done upon them, they were at the shortest possible time transferred to a laboratory where they went through various experiments to determine their content of raw protein, fat, ash, moisture, various fatty acids and their types, cholesterol, vitamins A and E, and such mineral elements as iron and calcium. All the experimentswere carried out three times to establish confidence in the results to be obtained. Findings of the comparison showed the content of raw protein, fat, moisture, and ash of, respectively, 23.233%, 600%, 73.077% and 2.500% for the Vannamei samples, of 22.717%, 427%, 74.133% and 1.826% for our Banana shrimps and of 17.377%, 430%, 79.866% and 1.313% for the Green Tiger samples. A total of 24 fatty acids for the Vannamei shrimps and 27 for the Banana and Green Tiger were detected. SFA of the Banana shrimps was 368.45 mg/100g (51.76%), while those of the Vannamei and Green Tiger samples were observed, respectively, 363.54 mg/100g (37.26%) and 296.06 mg/100g (49.12%).A similar measurement for MUFA content of the three types of our samples revealed 243.85mg/100g (24.9%) for the Vannamei, 203.177 mg/100g (33.76%) for the Green Tiger and 179.033 mg/100g (25.14%) for the Banana shrimps. The content of PUFA unsaturated fatty acids in the Vannamei, 131 Green Tiger and Banana samples were, respectively, 370.660 mg/100g (37.84%), 101.573 mg/100g (16.9%) and 163.733 mg/100g (23.1%). Further, the comparison found a omega-3-fatty-acids total of 151.747 mg/100g(15.51%) for the Vannamei, 57.123 mg/100g (9.54%) for the Green Tiger and 130.460 mg/100g (18.46%) for the Banana species under study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The article presents the forestry, fishery and ecological values of mangroves. Studies on the measurement of the economic value of mangroves that were conducted in Thailand, Indonesia and Ecuador are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducing a "Cheaper, Faster, Better" product in today's highly competitive market is a challenging target. Therefore, for organizations to improve their performance in this area, they need to adopt methods such as process modelling, risk mitigation and lean principles. Recently, several industries and researchers focused efforts on transferring the value orientation concept to other phases of the Product Life Cycle (PLC) such as Product Development (PD), after its evident success in manufacturing. In PD, value maximization, which is the main objective of lean theory, has been of particular interest as an improvement concept that can enhance process flow logistics and support decision-making. This paper presents an ongoing study of the current understanding of value thinking in PD (VPD) with a focus on value dimensions and implementation benefits. The purpose of this study is to consider the current state of knowledge regarding value thinking in PD, and to propose a definition of value and a framework for analyzing value delivery. The framework-named the Value Cycle Map (VCM)- intends to facilitate understanding of value and its delivery mechanism in the context of the PLC. We suggest the VCM could be used as a foundation for future research in value modelling and measurement in PD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of third-order dispersion in a Hong-Ou-Mandel interferometer is investigated using a ZnSe crystal as a dispersive medium. A value for the TOD coefficient of ZnSe is extracted which is consistent with literature values. © OSA 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Estrogenic activities of samples from two Chinese lakes, Ya-Er Lake and Donghu Lake, were measured by in vitro recombinant yeast assay and found in both lakes polluted with industrial and domestic wastewater. In methanol extracts of lake water samples the estrogen-like activity was higher than in toluene extracts. These results have been inverted for solid samples. Furthermore, the EC50 value of the water samples was close to the original concentration in the lake.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical waveguide propagation loss measurement method based on optical multiple reflections detection is presented in this paper. By using a precision reflectometer, uncertain influence on waveguide propagation loss measurement caused by fiber-waveguide coupling can be eliminated effectively and the waveguide net propagation loss can be measured accurately. To demonstrate this, the propagation loss of a Silicon-on-Insulator (SOI) rib waveguide fabricated by RIE is measured with the obtained value being 4.3 dB/cm. This method provides a non-destructive means for evaluating waveguide propagation loss. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is important to acquire the composition of Si1-xGex layer, especially that with high Ge content, epitaxied on Si substrate. Two nondestructive examination methods, double crystals X-ray diffraction (DCXRD) and micro-Raman measurement, were introduced comparatively to determine x value in Si1-xGex: layer, which show that while the two methods are consistent with each other when x is low, the results obtained from double crystals X-ray diffraction are not credible due to the large strain relaxation occurring in Si1-xGex layers when Ge content is higher than about 20%. Micro-Raman measurement is more appropriate for determining high Ge content than DCXRD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Absolute measurement of detector quantum efficiency using optical parametric down-conversion has been extensively studied for the case of a continuous wave pump. In this paper, we have used the temporally and spatially correlated properties of the down-converted photon pairs generated in a nonlinear crystal pumped by a femtosecond laser pulse to perform an absolute measurement of detector quantum efficiency. The measured detector quantum efficiency is in excellent agreement with the measured value in the conventional way. A lens with a long focal length was adopted for efficiently increasing the intensity of the down-conversion entangled photon source.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relative biological effectiveness (RBE) of carbon ions with linear energy transfer (LET) of 172 keV/mu m and 13.7 keV/mu m were determined in this study. The clonogenic survival and premature terminal differentiation were measured on normal human. broblasts AG01522C and NHDF after exposure of the cells to 250 kV X-rays and carbon ions with different qualities. RBE was determined for these two biological end points. The results showed that the measured RBE10 with a survival fraction of 10% was 3.2 for LET 172 keV/mu m, and 1.33 for LET 13.7 keV/mu m carbon ions. RBE for a doubling of post-mitotic. broblasts (PMF) in the population was 2.8 for LET 172 keV/mu m, and 1 for LET 13.7 keV/mu m carbon ions. For the carbon ion therapy, a high RBE value on the Bragg peak results in a high biological dose on the tumour. The tumour cells can be killed effectively. At the same time, the dose on healthy tissue would be reduced accordingly. This will lighten the late effect such as fibrosis on normal tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Super-FRS (Super FRagment Separator) is a part of FAIR (Facility for Antiproton and Ion Research), which will be constructed at GSI, Germany by 17 countries. The Super-FRS comprises 24 superferric dipole magnets. The 2D and 3D magnetic field simulations of the prototype magnet are described in this paper. A passive trim slot and four chamfered removable poles are used to satisfy the required field homogeneity which is better than +/-3 x 10(-4) at 1.6 T, 0.8 T and 0.16 T in a wide elliptical useable aperture of 380 mm x 140 mm. Measurement results at various field levels are shown in this paper as well. It can be seen from the comparison of calculation and measurement results that the magnetic designs of the magnet fulfils the requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The acid-base equilibrium of self-assembly monolayer(SAM) of mercaptopropionic acid on gold electrode was studied by capacitance titration. The change of capacitance was due to protonation and deprotonation of the modified electrode surface. This method can be used to measure pH value in solution and capacitance of solid/liquid on SAMs surface synchronously. The shift of pK(a) was observed during the experiment as previous reports. The factors that affect the capacitance measurement were discussed in detail.