914 resultados para Error Probability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: Results of valve re-replacement (reoperation) in 898 patients undergoing aortic valve replacement with cryopreserved homograft valves between 1975 and 1998 are reported. The study aim was to provide estimates of unconditional probability of valve reoperation and cumulative incidence function (actual risk) of reoperation. Methods: Valves were implanted by subcoronary insertion (n = 500), inclusion cylinder (n = 46), and aortic root replacement (n = 352). Probability of reoperation was estimated by adopting a mixture model framework within which estimates were adjusted for two risk factors: patient age at initial replacement, and implantation technique. Results: For a patient aged 50 years, the probability of reoperation in his/her lifetime was estimated as 44% and 56% for non-root and root replacement techniques, respectively. For a patient aged 70 years, estimated probability of reoperation was 16% and 25%, respectively. Given that a reoperation is required, patients with non-root replacement have a higher hazard rate than those with root replacement (hazards ratio = 1.4), indicating that non-root replacement patients tend to undergo reoperation earlier before death than root replacement patients. Conclusion: Younger patient age and root versus non-root replacement are risk factors for reoperation. Valve durability is much less in younger patients, while root replacement patients appear more likely to live longer and hence are more likely to require reoperation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that quantum feedback control can be used as a quantum-error-correction process for errors induced by a weak continuous measurement. In particular, when the error model is restricted to one, perfectly measured, error channel per physical qubit, quantum feedback can act to perfectly protect a stabilizer codespace. Using the stabilizer formalism we derive an explicit scheme, involving feedback and an additional constant Hamiltonian, to protect an (n-1)-qubit logical state encoded in n physical qubits. This works for both Poisson (jump) and white-noise (diffusion) measurement processes. Universal quantum computation is also possible in this scheme. As an example, we show that detected-spontaneous emission error correction with a driving Hamiltonian can greatly reduce the amount of redundancy required to protect a state from that which has been previously postulated [e.g., Alber , Phys. Rev. Lett. 86, 4402 (2001)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article deals with the efficiency of fractional integration parameter estimators. This study was based on Monte Carlo experiments involving simulated stochastic processes with integration orders in the range]-1,1[. The evaluated estimation methods were classified into two groups: heuristics and semiparametric/maximum likelihood (ML). The study revealed that the comparative efficiency of the estimators, measured by the lesser mean squared error, depends on the stationary/non-stationary and persistency/anti-persistency conditions of the series. The ML estimator was shown to be superior for stationary persistent processes; the wavelet spectrum-based estimators were better for non-stationary mean reversible and invertible anti-persistent processes; the weighted periodogram-based estimator was shown to be superior for non-invertible anti-persistent processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the investment decisions considering the presence of financial constraints of 373 large Brazilian firms from 1997 to 2004, using panel data. A Bayesian econometric model was used considering ridge regression for multicollinearity problems among the variables in the model. Prior distributions are assumed for the parameters, classifying the model into random or fixed effects. We used a Bayesian approach to estimate the parameters, considering normal and Student t distributions for the error and assumed that the initial values for the lagged dependent variable are not fixed, but generated by a random process. The recursive predictive density criterion was used for model comparisons. Twenty models were tested and the results indicated that multicollinearity does influence the value of the estimated parameters. Controlling for capital intensity, financial constraints are found to be more important for capital-intensive firms, probably due to their lower profitability indexes, higher fixed costs and higher degree of property diversification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a scheme which offers a significant reduction in the resources required to implement linear optics quantum computing. The scheme is a variation of the proposal of Knill, Laflamme and Milburn, and makes use of an incremental approach to the error encoding to boost probability of success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We theoretically study the Hilbert space structure of two neighboring P-donor electrons in silicon-based quantum computer architectures. To use electron spins as qubits, a crucial condition is the isolation of the electron spins from their environment, including the electronic orbital degrees of freedom. We provide detailed electronic structure calculations of both the single donor electron wave function and the two-electron pair wave function. We adopted a molecular orbital method for the two-electron problem, forming a basis with the calculated single donor electron orbitals. Our two-electron basis contains many singlet and triplet orbital excited states, in addition to the two simple ground state singlet and triplet orbitals usually used in the Heitler-London approximation to describe the two-electron donor pair wave function. We determined the excitation spectrum of the two-donor system, and study its dependence on strain, lattice position, and interdonor separation. This allows us to determine how isolated the ground state singlet and triplet orbitals are from the rest of the excited state Hilbert space. In addition to calculating the energy spectrum, we are also able to evaluate the exchange coupling between the two donor electrons, and the double occupancy probability that both electrons will reside on the same P donor. These two quantities are very important for logical operations in solid-state quantum computing devices, as a large exchange coupling achieves faster gating times, while the magnitude of the double occupancy probability can affect the error rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acceptance-probability-controlled simulated annealing with an adaptive move generation procedure, an optimization technique derived from the simulated annealing algorithm, is presented. The adaptive move generation procedure was compared against the random move generation procedure on seven multiminima test functions, as well as on the synthetic data, resembling the optical constants of a metal. In all cases the algorithm proved to have faster convergence and superior escaping from local minima. This algorithm was then applied to fit the model dielectric function to data for platinum and aluminum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The small sample performance of Granger causality tests under different model dimensions, degree of cointegration, direction of causality, and system stability are presented. Two tests based on maximum likelihood estimation of error-correction models (LR and WALD) are compared to a Wald test based on multivariate least squares estimation of a modified VAR (MWALD). In large samples all test statistics perform well in terms of size and power. For smaller samples, the LR and WALD tests perform better than the MWALD test. Overall, the LR test outperforms the other two in terms of size and power in small samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Biochemical analysis of fluid is the primary laboratory approach hi pleural effusion diagnosis. Standardization of the steps between collection and laboratorial analyses are fundamental to maintain the quality of the results. We evaluated the influence of temperature and storage time on sample stability. Methods: Pleural fluid from 30 patients was submitted to analyses of proteins, albumin, lactic dehydrogenase (LDH), cholesterol, triglycerides, and glucose. Aliquots were stored at 21 degrees, 4 degrees, and-20 degrees C, and concentrations were determined after 1, 2, 3, 4, 7, and 14 days. LDH isoenzymes were quantified in 7 random samples. Results: Due to the instability of isoenzymes 4 and 5, a decrease in LDH was observed in the first 24 h in samples maintained at -20 degrees C and after 2 days when maintained at 4 degrees C. Aside from glucose, all parameters were stable for up to at least day 4 when stored at room temperature or 4 degrees C. Conclusions: Temperature and storage time are potential preanalytical errors in pleural fluid analyses, mainly if we consider the instability of glucose and LDH. The ideal procedure is to execute all the tests immediately after collection. However, most of the tests can be done in refrigerated sample;, excepting LDH analysis. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To assess whether baseline Glaucoma Probability Score (GPS; HRT-3; Heidelberg Engineering, Dossenheim, Germany) results are predictive of progression in patients with suspected glaucoma. The GPS is a new feature of the confocal scanning laser ophthalmoscope that generates an operator-independent, three-dimensional model of the optic nerve head and gives a score for the probability that this model is consistent with glaucomatous damage. METHODS. The study included 223 patients with suspected glaucoma during an average follow-up of 63.3 months. Included subjects had a suspect optic disc appearance and/or elevated intraocular pressure, but normal visual fields. Conversion was defined as development of either repeatable abnormal visual fields or glaucomatous deterioration in the appearance of the optic disc during the study period. The association between baseline GPS and conversion was investigated by Cox regression models. RESULTS. Fifty-four (24.2%) eyes converted. In multivariate models, both higher values of GPS global and subjective stereophotograph assessment ( larger cup-disc ratio and glaucomatous grading) were predictive of conversion: adjusted hazard ratios (95% CI): 1.31 (1.15 - 1.50) per 0.1 higher global GPS, 1.34 (1.12 - 1.62) per 0.1 higher CDR, and 2.34 (1.22 - 4.47) for abnormal grading, respectively. No significant differences ( P > 0.05 for all comparisons) were found between the c-index values ( equivalent to area under ROC curve) for the multivariate models (0.732, 0.705, and 0.699, respectively). CONCLUSIONS. GPS values were predictive of conversion in our population of patients with suspected glaucoma. Further, they performed as well as subjective assessment of the optic disc. These results suggest that GPS could potentially replace stereophotograph as a tool for estimating the likelihood of conversion to glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parenteral anticoagulation is a cornerstone in the management of venous and arterial thrombosis. Unfractionated heparin has a wide dose/response relationship, requiring frequent and troublesome laboratorial follow-up. Because of all these factors, low-molecular-weight heparin use has been increasing. Inadequate dosage has been pointed out as a potential problem because the use of subjectively estimated weight instead of real measured weight is common practice in the emergency department (ED). To evaluate the impact of inadequate weight estimation on enoxaparin dosage, we investigated the adequacy of anticoagulation of patients in a tertiary ED where subjective weight estimation is common practice. We obtained the estimated, informed, and measured weight of 28 patients in need of parenteral anticoagulation. Basal and steady-state (after the second subcutaneous shot of enoxaparin) anti-Xa activity was obtained as a measure of adequate anticoagulation. The patients were divided into 2 groups according the anticoagulation adequacy. From the 28 patients enrolled, 75% (group 1, n = 21) received at least 0.9 mg/kg per dose BID and 25% (group 2, n = 7) received less than 0.9 mg/kg per dose BID of enoxaparin. Only 4 (14.3%) of all patients had anti-Xa activity less than the inferior limit of the therapeutic range (<0.5 UI/mL), all of them from group 2. In conclusion, when weight estimation was used to determine the enoxaparin dosage, 25% of the patients were inadequately anticoagulated (anti-Xa activity <0.5 UI/mL) during the initial crucial phase of treatment. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the statistical properties of the local density of states of a one-dimensional Dirac equation in the presence of various types of disorder with Gaussian white-noise distribution. It is shown how either the replica trick or supersymmetry can be used to calculate exactly all the moments of the local density of states.' Careful attention is paid to how the results change if the local density of states is averaged over atomic length scales. For both the replica trick and supersymmetry the problem is reduced to finding the ground state of a zero-dimensional Hamiltonian which is written solely in terms of a pair of coupled spins which are elements of u(1, 1). This ground state is explicitly found for the particular case of the Dirac equation corresponding to an infinite metallic quantum wire with a single conduction channel. The calculated moments of the local density of states agree with those found previously by Al'tshuler and Prigodin [Sov. Phys. JETP 68 (1989) 198] using a technique based on recursion relations for Feynman diagrams. (C) 2001 Elsevier Science B.V. All rights reserved.