897 resultados para Energy consumption survey
Resumo:
The simulation analysis is important approach to developing and evaluating the systems in terms of development time and cost. This paper demonstrates the application of Time Division Cluster Scheduling (TDCS) tool for the configuration of IEEE 802.15.4/ZigBee beaconenabled cluster-tree WSNs using the simulation analysis, as an illustrative example that confirms the practical applicability of the tool. The simulation study analyses how the number of retransmissions impacts the reliability of data transmission, the energy consumption of the nodes and the end-to-end communication delay, based on the simulation model that was implemented in the Opnet Modeler. The configuration parameters of the network are obtained directly from the TDCS tool. The simulation results show that the number of retransmissions impacts the reliability, the energy consumption and the end-to-end delay, in a way that improving the one may degrade the others.
Resumo:
In this work a mixed integer optimization linear programming (MILP) model was applied to mixed line rate (MLR) IP over WDM and IP over OTN over WDM (with and without OTN grooming) networks, with aim to reduce network energy consumption. Energy-aware and energy-aware & short-path routing techniques were used. Simulations were made based on a real network topology as well as on forecasts of traffic matrix based on statistical data from 2005 up to 2017. Energy aware routing optimization model on IPoWDM network, showed the lowest energy consumption along all years, and once compared with energy-aware & short-path routing, has led to an overall reduction in energy consumption up to 29%, expecting to save even more than shortest-path routing. © 2014 IEEE.
Resumo:
OBJECTIVE To assess the impact of consuming ultra-processed foods on the nutritional dietary profile in Brazil.METHODS Cross-sectional study conducted with data from the module on individual food consumption from the 2008-2009 Pesquisa de Orçamentos Familiares (POF – Brazilian Family Budgets Survey). The sample, which represented the section of the Brazilian population aged 10 years or over, involved 32,898 individuals. Food consumption was evaluated by two 24-hour food records. The consumed food items were classified into three groups: natural or minimally processed, including culinary preparations with these foods used as a base; processed; and ultra-processed.RESULTS The average daily energy consumption per capita was 1,866 kcal, with 69.5% being provided by natural or minimally processed foods, 9.0% by processed foods and 21.5% by ultra-processed food. The nutritional profile of the fraction of ultra-processed food consumption showed higher energy density, higher overall fat content, higher saturated and trans fat, higher levels of free sugar and less fiber, protein, sodium and potassium, when compared to the fraction of consumption related to natural or minimally processed foods. Ultra-processed foods presented generally unfavorable characteristics when compared to processed foods. Greater inclusion of ultra-processed foods in the diet resulted in a general deterioration in the dietary nutritional profile. The indicators of the nutritional dietary profile of Brazilians who consumed less ultra-processed foods, with the exception of sodium, are the stratum of the population closer to international recommendations for a healthy diet.CONCLUSIONS The results from this study highlight the damage to health that is arising based on the observed trend in Brazil of replacing traditional meals, based on natural or minimally processed foods, with ultra-processed foods. These results also support the recommendation of avoiding the consumption of these kinds of foods.
Resumo:
This study addresses to the optimization of pultrusion manufacturing process from the energy-consumption point of view. The die heating system of external platen heaters commonly used in the pultrusion machines is one of the components that contribute the most to the high consumption of energy of pultrusion process. Hence, instead of the conventional multi-planar heaters, a new internal die heating system that leads to minor heat losses is proposed. The effect of the number and relative position of the embedded heaters along the die is also analysed towards the setting up of the optimum arrangement that minimizes both the energy rate and consumption. Simulation and optimization processes were greatly supported by Finite Element Analysis (FEA) and calibrated with basis on the temperature profile computed through thermography imaging techniques. The main outputs of this study allow to conclude that the use of embedded cylindrical resistances instead of external planar heaters leads to drastic reductions of both the power consumption and the warm-up periods of the die heating system. For the analysed die tool and process, savings on energy consumption up to 60% and warm-up period stages less than an half hour were attained with the new internal heating system. The improvements achieved allow reducing the power requirements on pultrusion process, and thus minimize industrial costs and contribute to a more sustainable pultrusion manufacturing industry.
Resumo:
This paper presents the system developed to promote the rational use of electric energy among consumers and, thus, increase the energy efficiency. The goal is to provide energy consumers with an application that displays the energy consumption/production profiles, sets up consuming ceilings, defines automatic alerts and alarms, compares anonymously consumers with identical energy usage profiles by region and predicts, in the case of non-residential installations, the expected consumption/production values. The resulting distributed system is organized in two main blocks: front-end and back-end. The front-end includes user interface applications for Android mobile devices and Web browsers. The back-end provides data storage and processing functionalities and is installed in a cloud computing platform - the Google App Engine - which provides a standard Web service interface. This option ensures interoperability, scalability and robustness to the system.
Impact of design options in zero energy building conception: the case of large buildings in Portugal
Resumo:
The new recast of Directive 2010/31/EU in order to implement the new concept NZEB in new buildings, is to be fully respected by all Member States, and is revealed as important measure to promote the reduction of energy consumption of buildings and encouraging the use of renewable energy. In this study, it was tested the applicability of the nearly zero energy building concept to a big size office building and its impact after a 50-years life cycle span.
Resumo:
Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Energy consumption is one of the major issues for modern embedded systems. Early, power saving approaches mainly focused on dynamic power dissipation, while neglecting the static (leakage) energy consumption. However, technology improvements resulted in a case where static power dissipation increasingly dominates. Addressing this issue, hardware vendors have equipped modern processors with several sleep states. We propose a set of leakage-aware energy management approaches that reduce the energy consumption of embedded real-time systems while respecting the real-time constraints. Our algorithms are based on the race-to-halt strategy that tends to run the system at top speed with an aim to create long idle intervals, which are used to deploy a sleep state. The effectiveness of our algorithms is illustrated with an extensive set of simulations that show an improvement of up to 8% reduction in energy consumption over existing work at high utilization. The complexity of our algorithms is smaller when compared to state-of-the-art algorithms. We also eliminate assumptions made in the related work that restrict the practical application of the respective algorithms. Moreover, a novel study about the relation between the use of sleep intervals and the number of pre-emptions is also presented utilizing a large set of simulation results, where our algorithms reduce the experienced number of pre-emptions in all cases. Our results show that sleep states in general can save up to 30% of the overall number of pre-emptions when compared to the sleep-agnostic earliest-deadline-first algorithm.
Resumo:
Um dos princípios da Gestão é: “If you cannot measure it, you cannot improve it.” In The Economist – 26.Dez.2008, idea of 19th century English physicist Lord Kelvin. Embora seja uma afirmação aplicável à gestão económica, também pode ser utilizada no domínio da gestão da energia. Este trabalho surge da necessidade sentida pela empresa Continental - Industria Têxtil do Ave, S.A. em efetuar uma atualização dos seus standards de produção, minimizando os seus consumos de eletricidade e gás natural. Foi necessário efetuar o levantamento dos consumos em diversas máquinas e equipamentos industriais, caracterizando e analisando os consumos ao longo de todo o processo produtivo. Para o tratamento de dados recolhidos foi desenvolvida uma folha de cálculo em MS Office ExcelTM com metodologia adequada ao equipamento em análise, que dará apoio ao decisor para a identificação dos aspetos que melhorem o processo produtivo e garantam uma elevada eficiência energética. Porém, não se enquadra no âmbito do Plano Nacional de Racionalização de Energia, sendo uma “auditoria energética” ao processo produtivo. Recentemente, a empresa, tem vindo a utilizar equipamentos eletrónicos que permitem otimizar o funcionamento mecânico dos equipamentos e das potências instaladas dos transformadores, na tentativa de racionalizar o consumo da energia elétrica. Outros equipamentos como, conversores de frequência para controlo de motores, balastros eletrónicos que substituem os convencionais balastros ferromagnéticos das lâmpadas de descarga fluorescente, têm sido incluídos ao nível das instalações elétricas, sendo gradualmente substituída a eletromecânica pela eletrónica. Este tipo de soluções vem deteriorar as formas de onda da corrente e da tensão do sistema pela introdução de distorções harmónicas. Faz ainda parte deste trabalho, um estudo de uma solução que melhore, simultaneamente o fator de potência e reduza as harmónicas presentes num posto de transformação localizado no seio da fábrica. Esta solução, permite melhorar a qualidade da energia elétrica e as condições de continuidade de serviço, garantindo melhores condições de exploração e incrementando a produtividade da empresa.
Resumo:
Recent and future changes in power systems, mainly in the smart grid operation context, are related to a high complexity of power networks operation. This leads to more complex communications and to higher network elements monitoring and control levels, both from network’s and consumers’ standpoint. The present work focuses on a real scenario of the LASIE laboratory, located at the Polytechnic of Porto. Laboratory systems are managed by the SCADA House Intelligent Management (SHIM), already developed by the authors based on a SCADA system. The SHIM capacities have been recently improved by including real-time simulation from Opal RT. This makes possible the integration of Matlab®/Simulink® real-time simulation models. The main goal of the present paper is to compare the advantages of the resulting improved system, while managing the energy consumption of a domestic consumer.
Resumo:
The recent changes concerning the consumers’ active participation in the efficient management of load devices for one’s own interest and for the interest of the network operator, namely in the context of demand response, leads to the need for improved algorithms and tools. A continuous consumption optimization algorithm has been improved in order to better manage the shifted demand. It has been done in a simulation and user-interaction tool capable of being integrated in a multi-agent smart grid simulator already developed, and also capable of integrating several optimization algorithms to manage real and simulated loads. The case study of this paper enhances the advantages of the proposed algorithm and the benefits of using the developed simulation and user interaction tool.
Resumo:
Atualmente a energia é considerada um vetor estratégico nas diversas organizações. Assim sendo, a gestão e a utilização racional da energia são consideradas instrumentos fundamentais para a redução dos consumos associados aos processos de produção do sector industrial. As ações de gestão energética não deverão ficar pela fase do projeto das instalações e dos meios de produção, mas sim acompanhar a atividade da Empresa. A gestão da energia deve ser sustentada com base na realização regular de diagnósticos energéticos às instalações consumidoras e concretizada através de planos de atuação e de investimento que apresentem como principal objetivo a promoção da eficiência energética, conduzindo assim à redução dos respetivos consumos e, consequentemente, à redução da fatura energética. Neste contexto, a utilização de ferramentas de apoio à gestão de energia promovem um consumo energético mais racional, ou seja, promovem a eficiência energética e é neste sentido que se insere este trabalho. O presente trabalho foi desenvolvido na Empresa RAR Açúcar e apresentou como principais objetivos: a reformulação do Sistema de Gestão de Consumos de Energia da Empresa, a criação de um modelo quantitativo que permitisse ao Gestor de Energia prever os consumos anuais de água, fuelóleo e eletricidade da Refinaria e a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado. A reformulação do respetivo Sistema de Gestão de Consumos resultou de um conjunto de etapas. Numa primeira fase foi necessário efetuar uma caraterização e uma análise do atual Sistema de Gestão de Consumos da Empresa, sistema composto por um conjunto de sete ficheiros de cálculo do programa Microsoft Excel©. Terminada a análise, selecionada a informação pertinente e propostas todas as melhorias a introduzir nos ficheiros, procedeu-se à reformulação do respetivo SGE, reduzindo-se o conjunto de ficheiros de cálculo para apenas dois ficheiros, um onde serão efetuados e visualizados todos os registos e outro onde serão realizados os cálculos necessários para o controlo energético da Empresa. O novo Sistema de Gestão de Consumos de Energia será implementado no início do ano de 2015. Relativamente às alterações propostas para as folhas de registos manuais, estas já foram implementadas pela Empresa. Esta aplicação prática mostrou-se bastante eficiente uma vez que permitiu grandes melhorias processuais nomeadamente, menores tempos de preenchimento das mesmas e um encurtamento das rotas efetuadas diariamente pelos operadores. Através do levantamento efetuado aos diversos contadores foi possível identificar todas as áreas onde será necessário a sua instalação e a substituição de todos os contadores avariados, permitindo deste modo uma contabilização mais precisa de todos os consumos da Empresa. Com esta reestruturação o Sistema de Gestão de Consumos tornou-se mais dinâmico, mais claro e, principalmente, mais eficiente. Para a criação do modelo de previsão de consumos da Empresa foi necessário efetuar-se um levantamento dos consumos históricos de água, eletricidade, fuelóleo e produção de açúcar de dois anos. Após este levantamento determinaram-se os consumos específicos de água, fuelóleo e eletricidade diários (para cada semana dos dois anos) e procedeu-se à caracterização destes consumos por tipo de dia. Efetuada a caracterização definiu-se para cada tipo de dia um consumo específico médio com base nos dois anos. O modelo de previsão de consumos foi criado com base nos consumos específicos médios dos dois anos correspondentes a cada tipo de dia. Procedeu-se por fim à verificação do modelo, comparando-se os consumos obtidos através do modelo (consumos previstos) com os consumos reais de cada ano. Para o ano de 2012 o modelo apresenta um desvio de 6% na previsão da água, 12% na previsão da eletricidade e de 6% na previsão do fuelóleo. Em relação ao ano de 2013, o modelo apresenta um erro de 1% para a previsão dos consumos de água, 8% para o fuelóleo e de 1% para a eletricidade. Este modelo permitirá efetuar contratos de aquisição de energia elétrica com maior rigor o que conduzirá a vantagens na sua negociação e consequentemente numa redução dos custos resultantes da aquisição da mesma. Permitirá também uma adequação dos fluxos de tesouraria à necessidade reais da Empresa, resultante de um modelo de previsão mais rigoroso e que se traduz numa mais-valia financeira para a mesma. Foi também proposto a elaboração de um plano de consumos para o ano de 2014 a partir do modelo criado em função da produção prevista para esse mesmo ano. O modelo apresenta um desvio de 24% na previsão da água, 0% na previsão da eletricidade e de 28% na previsão do fuelóleo.
Resumo:
Atualmente, o parque edificado é responsável pelo consumo de 40% da energia total consumida em toda a União Europeia. As previsões apontam para o crescimento do sector da construção civil, nomeadamente a construção de edifícios, o que permite perspetivar um aumento do consumo de energia nesta área. Medidas importantes, como o lançamento da Diretiva 2010/31/EU do Parlamento Europeu e do Conselho de 19 de Maio de 2010 relativa ao desempenho energético dos edifícios, abrem caminho para a diminuição das necessidades energéticas e emissões de gases de efeito de estufa. Nela são apontados objetivos para aumentar a eficiência energética do parque edificado, tendo como objetivo que a partir de 2020 todos os novos edifícios sejam energeticamente eficientes e de balanço energético quase zero, com principal destaque para a compensação usando produção energética própria proveniente de fontes renováveis. Este novo requisito, denominado nearly zero energy building, apresenta-se como um novo incentivo no caminho para a sustentabilidade energética. As técnicas e tecnologias usadas na conceção dos edifícios terão um impacto positivo na análise de ciclo de vida, nomeadamente na minimização do impacto ambiental e na racionalização do consumo energético. Desta forma, pretendeu-se analisar a aplicabilidade do conceito nearly zero energy building a um grande edifício de serviços e o seu impacto em termos de ciclo de vida a 50 anos. Partindo da análise de alguns estudos sobre o consumo energético e sobre edifícios de balanço energético quase nulo já construídos em Portugal, desenvolveu-se uma análise de ciclo de vida para o caso de um edifício de serviços, da qual resultou um conjunto de propostas de otimização da sua eficiência energética e de captação de energias renováveis. As medidas apresentadas foram avaliadas com o auxílio de diferentes aplicações como DIALux, IES VE e o PVsyst, com o objetivo de verificar o seu impacto através da comparação com estado inicial de consumo energético do edifício. Nas condições iniciais, o resultado da análise de ciclo de vida do edifício a 50 anos no que respeita ao consumo energético e respetivas emissões de CO2 na fase de operação foi de 6 MWh/m2 e 1,62 t/m2, respetivamente. Com aplicação de medidas propostas de otimização, o consumo e as respetivas emissões de CO2 foram reduzidas para 5,2 MWh/m2 e 1,37 t/m2 respetivamente. Embora se tenha conseguido reduzir ao consumo com as medidas propostas de otimização de energia, chegou-se à conclusão que o sistema fotovoltaico dimensionado para fornecer energia ao edifício não consegue satisfazer as necessidades energéticas do edifício no final dos 50 anos.
Resumo:
Heterogeneous multicore platforms are becoming an interesting alternative for embedded computing systems with limited power supply as they can execute specific tasks in an efficient manner. Nonetheless, one of the main challenges of such platforms consists of optimising the energy consumption in the presence of temporal constraints. This paper addresses the problem of task-to-core allocation onto heterogeneous multicore platforms such that the overall energy consumption of the system is minimised. To this end, we propose a two-phase approach that considers both dynamic and leakage energy consumption: (i) the first phase allocates tasks to the cores such that the dynamic energy consumption is reduced; (ii) the second phase refines the allocation performed in the first phase in order to achieve better sleep states by trading off the dynamic energy consumption with the reduction in leakage energy consumption. This hybrid approach considers core frequency set-points, tasks energy consumption and sleep states of the cores to reduce the energy consumption of the system. Major value has been placed on a realistic power model which increases the practical relevance of the proposed approach. Finally, extensive simulations have been carried out to demonstrate the effectiveness of the proposed algorithm. In the best-case, savings up to 18% of energy are reached over the first fit algorithm, which has shown, in previous works, to perform better than other bin-packing heuristics for the target heterogeneous multicore platform.
Resumo:
Coarse Grained Reconfigurable Architectures (CGRAs) are emerging as enabling platforms to meet the high performance demanded by modern applications (e.g. 4G, CDMA, etc.). Recently proposed CGRAs offer time-multiplexing and dynamic applications parallelism to enhance device utilization and reduce energy consumption at the cost of additional memory (up to 50% area of the overall platform). To reduce the memory overheads, novel CGRAs employ either statistical compression, intermediate compact representation, or multicasting. Each compaction technique has different properties (i.e. compression ratio, decompression time and decompression energy) and is best suited for a particular class of applications. However, existing research only deals with these methods separately. Moreover, they only analyze the compaction ratio and do not evaluate the associated energy overheads. To tackle these issues, we propose a polymorphic compression architecture that interleaves these techniques in a unique platform. The proposed architecture allows each application to take advantage of a separate compression/decompression hierarchy (consisting of various types and implementations of hardware/software decoders) tailored to its needs. Simulation results, using different applications (FFT, Matrix multiplication, and WLAN), reveal that the choice of compression hierarchy has a significant impact on compression ratio (up to 52%), decompression energy (up to 4 orders of magnitude), and configuration time (from 33 n to 1.5 s) for the tested applications. Synthesis results reveal that introducing adaptivity incurs negligible additional overheads (1%) compared to the overall platform area.