982 resultados para END FILLING MATERIALS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the emergence of new filling materials with different properties and behaviors, the approach of endodontic treatment must be readjusted so that the appropriate result can be achieved. New endodontic sealers include methacrylate resin-based, plant resin-based and the evolution of epoxy-based sealers. This study verified the behavior of new materials that presents controversial results in the literature, about coronal bacterial leakage. That for, 56 single-rooted human teeth were prepared in the direction crown-apex and filled with gutta-percha points with taper of 4% using the single cone technique. Roots were divided randomly into 4 groups according to the sealer (Apexit Plus, AH Plus, EndoREZ and Polifil). After filling, the roots were incorporated in a leakage model, which upper chamber contained a suspension of Streptococcus mutans, and lower chamber a broth, leaving 3 mm of root apical portion immersed. Leakage was assessed for turbidity in lower chamber every day for 60 days. Survival analysis was performed using the nonparametric Kaplan- Meier method (p<0,05). All experimental groups presented leakage during the study’s period, however the maximum time achieve was 22 days. The medium time of leakage was: Apexit Plus 6,3 days, AH Plus 6,3 days and Polifil 5,1 days, but in EndoREZ all specimens infiltrated in the first day, presenting shorter capacity of impermeabilization compared to the other groups. Concluding that none of the sealers tested was able to prevent coronal bacterial leakage

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of coronal leakage on concentration of hydrogen ions (pH) and calcium release of several calcium hydroxide pastes, over different periods of time. Material and Methods: Fifty extracted human mandibular central incisors (n=10) were instrumented up to the F2 instrument and assigned to the following intracanal dressing: G1- Calen, G2- Calen with 0.4% chlorhexidine (CHX), G3- Calcium hydroxide with camphorated paramonochlorophenol (CPMC) and glycerin, G4- Calen, but temporary filling material maintained during all test (positive control) and G5- Root canal without intracanal dressing (negative control). All groups were immersed in distilled water for 7 days. In sequence, the temporary filling materials were removed, except in controls groups. All specimens were individually mounted on a specific device and only its root again immersed in distilled water. Concentration of hydrogen ions and calcium release by calcium hydroxide pastes in distilled water were evaluated in 24h, 7, 14 and 28 days. The results were submitted to ANOVA test (p = 0.05). After 28 days, root canals from experimental groups were examined in SEM. Results: G1, G2, G3 and G4 presented similar pH values and calcium release and did not differ from each other (p>0.05), up to 7 days. After this time G1, G2 and G3 presented values lower values than G4 (p<0.05). In SEM analysis, calcium hydroxide residues were observed in all experimental groups. Conclusions: After 7 days, coronal leakage decreased the concentration of hydrogen ions and calcium ion release provided by all calcium hydroxide pastes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: The aims of this study were to assess the penetration of two endodontic sealers (salicylate and epoxy resin-based sealers) into dentinal tubules using CLSM; and to evaluate the bacterial leakage of roots filled with the same sealers associated with gutta-percha. Material and Methods: For sealer penetrability assessment, thirty bovine roots were instrumented and divided into three groups: AHP: EDTA + filling with AH Plus and gutta-percha (n=10), MTAF: EDTA + filling with MTA Fillapex and gutta-percha (n=10), control group: canals were not irrigated with EDTA and were filled with gutta-percha and AH Plus (n=5) or MTA Fillapex (n=5). Rhodamine B was added to the sealers in order to provide adequate fluorescence. The roots were transversely sectioned 3mm from the apex to enable CLSM analysis. Leakage was evaluated for turbidity of the broth in a split chamber model system for 30 days, using Enterococcus faecalis as a microbial marker. Thirty roots were instrumented and divided in four grupos: AHP: filling with AH Plus and gutta-percha (n=10); MTAF: filling with MTA Fillapex and gutta-percha (n=10); positive control: filling with gutta-percha without sealer (n = 5); negative control: sealing with cyanoacrylate to test the seal of the system (n = 5). Results: The medians for dentinal tubule penetration were 6.8% (AHP) and 6.6% (MTAF) (P = 0.82). The average time for bacterial leakage was 8 days in both experimental groups (P = 0.79). Conclusion: MTA Fillapex and AH Plus presented similar behavior regarding dentinal tubule penetration and bacterial leakage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The adhesiveness of six root canal sealers: Acroseal, Endo CPM, Epiphany, White MTA, Sealapex and Sealer 26 to dentin, was evaluated in a push-out test design. Methods: Twenty eight roots of freshly extracted teeth were gauged with a size 5 Largo drill. With a cutting machine slices of 2 mm were prepared, rinsed with 5.25% NaOCl and a final rinse with 17% EDTA, dried and filled with one of the sealers. After setting their bond strength was measured in a mechanical testing machine. The data were statistically analyzed by using a One Way ANOVA and post hoc Tukey test. Results: The mean and standard deviation from values of bond strength was: Sealapex 2.2±0.4; Endo CPM 3.8±1.3; White MTA 6.0±1.4; Epiphany 10.9±2.6; Sealer 26 12.3±2.3; and Acroseal 12.2±1.4. Acroseal, Sealer 26 and Epiphany presented a significantly (P<0.01) greater bond strength compared with the other sealers. Also White MTA showed higher adhesiveness compared with Endo CPM and Sealapex (P<0.01). Conclusion: The bond strength between endodontic sealers and root dentin was maximal when Acroseal, Sealer 26 and Epiphany were used; Sealapex e Endo CPM, in turn, presented the lowest bond strength mean values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was carried out to observe if the status of the root canal might influence the healing process of surgically prepared experimental periodontal lesions. Forty tooth roots from four dogs were divided into four different groups: a) root canals with vital pulps, b) root canals open to the oral environment, c) root canals infected and filled with zinc oxide eugenol cement, and d) root canals infected and filled with calcium hydroxide. By means of a surgical intervention, a cavity was prepared in the medium portion of the roots. Six months later, the specimens were removed and prepared for histological analysis. The results, which were submitted to statistical analysis, showed that the status of the root canals influenced the healing process of the experimental periodontal lesions. In the groups where the root canals were filled, calcium hydroxide gave the best results. In the group with root canals left open to the oral environment, resorption of the dentin of the experimental cavities, was the most obvious observation. However, it did not prevent the repair process, only slowed it down.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Eighty root canals of the premolars of 4 dogs, with vital pulp, were instrumented and filled during the same session with the Sealapex, CRCS, Sealer 26, and Apexit sealers, the animals were sacrificed 180 days after root canal filling and their maxillae and mandibles were removed and fixed in 10% formalin, After routine histologic processing, the sections were stained with hematoxylin-eosin and Mallory trichrome, Histopathologic analysis showed that Sealapex was the sealer that best permitted the deposition of mineralized tissue at the apical level and was the only sealer that provided complete sealing (37.5% of cases), With the use of Sealapex, no inflammatory infiltrate occurred and there was no reabsorption of mineralized tissues, In contrast, partial sealing and a moderate inflammatory infiltrate occurred with the use of CRCS, When Apexit and Sealer 26 were used the absence of sealing was frequent and active reabsorption of mineralized tissues occurred in most cases, the inflammatory infiltrate predominating with the use of Apexit was of the severe type, whereas with the use of Sealer 26 the inflammatory infiltrate was mild or absent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Teeth that have lost much of their coronal tooth structure need intraradical devices to achieve a desired retention of the restorative material, restoring aesthetics and function to the patient. For this purpose, various types of intracanal posts have been studied, of wich the fiber posts have been highlighted with its increasing use in the dental market. The purpose of this study was to present a clinical case of using fiberglass post. As well as critically analyze the published works and points of controversy described by different authors related to factors such as different protocols cementation, surface treatments pins, fracture toughness and compression, the possibility of microleakage, diameter and length of the pin, and the various materials used in conjunction with the intracanal retainers. Thus, we concluded that fiber posts showed as an excellent alternative for anterior teeth, since have least 2 mm of tooth remaining.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Implant dentistry is a dental specialty which presents great predictability in the rehabilitation at posterior, partially edentulous maxillary areas. Early tooth loss results in significant jaw remodeling. The maxillary sinus lifting followed by implant placement is a predictable technique initially described in 1980. Since then, several different techniques have been investigated varying filling materials and the management of complications in order to provide effective guidance in the rehabilitation of these patients. The current study evaluated ten patients who underwent sinus lifting before implant placement and crown installation. First, a retrospective analysis of the medical records was conducted to obtain information about possible postoperative complications. Clinical and radiographic analyses were performed at baseline and 180 days after surgeries. The sinus lifting with immediate implant placement provided satisfactory outcomes and can be considered a safe procedure. Treatment predictability was demonstrated in 90% of patients and for 86.96% of implants placed. It is important to highlight knowledge of anatomical structures at this area, the use of delicate surgical techniques, and strict patient follow-up.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives. To verify the hypothesis that crack analysis and a mechanical test would rank a series of composites in a similar order with respect to polymerization stress. Also, both tests would show similar relationships between stress and composite elastic modulus and/or shrinkage. Methods. Soda-lime glass discs (2-mm thick) with a central perforation (3.5-mm diameter) received four Vickers indentations 500 mu m from the cavity margin. The indent cracks were measured (500x) prior and 10 min after the cavity was restored with one of six materials (Kalore/KL, Gradia/GR, Ice/IC, Wave/WV, Majesty Flow/MF, and Majesty Posterior/MP). Stresses at the indent site were calculated based on glass fracture toughness and increase in crack length. Stress at the bonded interface was calculated using the equation for an internally pressurized cylinder. The mechanical test used a universal testing machine and glass rods (5-mm diameter) as substrate. An extensometer monitored specimen height (2 mm). Nominal stress was calculated dividing the maximum shrinkage force by the specimen cross-sectional area. Composite elastic modulus was determined by nanoindentation and post-gel shrinkage was measured using strain gages. Data were subjected to one-way ANOVA/Tukey or Kruskal-Wallis/Mann-Whitney tests (alpha: 5%). Results. Both tests grouped the composites in three statistical subsets, with small differences in overlapping between the intermediate subset (MF, WV) and the highest (MP, IC) or the lowest stress materials (KL, GR). Higher stresses were developed by composites with high modulus and/or high shrinkage. Significance. Crack analysis demonstrated to be as effective as the mechanical test to rank composites regarding polymerization stress. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10x), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Microsc. Res. Tech. 75:12331236, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).