972 resultados para EMITTING DIODE
Resumo:
P>Although photodynamic therapy (PDT) has shown great promise for the inactivation of Candida species, its effectiveness against azole-resistant pathogens remains poorly documented. This in vitro study describes the association of Photogem (R) (Photogem, Moscow, Russia) with LED (light emitting diode) light for the photoinactivation of fluconazole-resistant (FR) and American Type Culture Collection (ATCC) strains of Candida albicans and Candida glabrata. Suspensions of each Candida strain were treated with five Photogem (R) concentrations and exposed to four LED light fluences (14, 24, 34 or 50 min of illumination). After incubation (48 h at 37 degrees C), colonies were counted (CFU ml-1). Single-species biofilms were generated on cellulose membrane filters, treated with 25.0 mg l-1 of Photogem (R) and illuminated at 37.5 J cm-2. The biofilms were then disrupted and the viable yeast cells present were determined. Planktonic suspensions of FR strains were effectively killed after PDT. It was observed that the fungicidal effect of PDT was strain-dependent. Significant decreases in biofilm viability were observed for three strains of C. albicans and for two strains of C. glabrata. The results of this investigation demonstrated that although PDT was effective against Candida species, fluconazole-resistant strains showed reduced sensitivity to PDT. Moreover, single-species biofilms were less susceptible to PDT than their planktonic counterparts.
Resumo:
In order to consider the photodynamic therapy (PDT) as a clinical treatment for candidosis, it is necessary to know its cytotoxic effect on normal cells and tissues. Therefore, this study evaluated the toxicity of PDT with PhotogemA (R) associated with red light-emitting diode (LED) on L929 and MDPC-23 cell cultures and healthy rat palatal mucosa. In the in vitro experiment, the cells (30000 cells/cm(2)) were seeded in 24-well plates for 48 h, incubated with PhotogemA (R) (50, 100, or 150 mg/l) and either irradiated or not with a red LED source (630 +/- 3 nm; 75 or 100 J/cm(2); 22 mW/cm(2)). Cell metabolism was evaluated by the MTT assay (ANOVA and Dunnet`s post hoc tests; p < 0.05) and cell morphology was examined by scanning electron microscopy. In the in vivo evaluation, PhotogemA (R) (500 mg/l) was applied to the palatal mucosa of Wistar rats during 30 min and exposed to red LED (630 nm) during 20 min (306 J/cm(2)). The palatal mucosa was photographed for macroscopic analysis at 0, 1, 3, and 7 days posttreatment and subjected to histological analysis after sacrifice of the rats. For both cell lines, there was a statistically significant decrease of the mitochondrial activity (90-97%) for all PhotogemA (R) concentrations associated with red LED regardless of the energy density. However, in the in vivo evaluation, the PDT-treated groups presented intact mucosa with normal characteristics both macroscopically and histologically. From these results, it may be concluded that the association of PhotogemA (R) and red LED caused severe toxic effects on normal cell cultures, characterized by the reduction of mitochondrial activity and morphological alterations, but did not cause damage to the rat palatal mucosa in vivo.
Resumo:
Thermal properties and degree of conversion (DC%) of two composite resins (microhybrid and nanocomposite) and two photo-activation methods (continuous and gradual) displayed by the light-emitting diode (LED) light-curing units (LCUs) were investigated in this study. Differential scanning calorimetry (DSC) thermal analysis technique was used to investigate the glass transition temperature (T(g)) and degradation temperature. The DC% was determined by Fourier transform infrared spectroscopy (FT-IR). The results showed that the microhybrid composite resin presented the highest T(g) and degradation temperature values, i.e., the best thermal stability. Gradual photo-activation methods showed higher or similar T(g) and degradation temperature values when compared to continuous method. The Elipar Freelight 2 (TM) LCU showed the lowest T(g) values. With respect to the DC%, the photo-activation method did not influence the final conversion of composite resins. However, Elipar Freelight 2 (TM) LCU and microhybrid resin showed the lowest DC% values. Thus, the presented results suggest that gradual method photo-activation with LED LCUs provides adequate degree of conversion without promoting changes in the polymer chain of composite resins. However, the thermal properties and final conversion of composite resins can be influenced by the kind of composite resin and LCU.
Resumo:
The aim of this study was to evaluate the degree of conversion and hardness of a dental composite resin Filtek (TM) Z-350 (3M ESPE, Dental Products St. Paul, MN) photo-activated for 20 s of irradiation time with two different light guide tips, metal and polymer, coupled on blue LED Ultraled LCU (Dabi Atlante, SP, Brazil). With the metal light tip, power density was of 352 and with the polymer was of 456 mW/cm(2), respectively. Five samples (4 mm in diameter and 2mm in thickness-ISO 4049), were made for each Group evaluated. The measurements for DC (%) were made in a Nexus-470 FT-IR, Thermo Nicolet, E.U.A. Spectroscopy (FTIR). Spectra for both uncured and cured samples were analyzed using an accessory of reflectance diffuse. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm(-1) resolution, 300-4000 cm(-1) wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm(-1)) against internal standard before and after curing of the sample: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements (top and bottom surfaces) were performed in a universal testing machine (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). A 50 gf load was used and the indenter with a dwell time of 30 s. The data were submitted to the test t Student at significance level of 5%. The mean values of degree of conversion for the polymer and metal light guide tip no were statistically different (p = 0.8389). The hardness mean values were no statistically significant different among the light guide tips (p = 0.6244), however, there was difference between top and bottom surfaces (p < 0.001). The results show that so much the polymer light tip as the metal light tip can be used for the photo-activation, probably for the low quality of the light guide tip metal.
Resumo:
Dentin hypersensitivity is a common condition associated with high dental pain. A new LED-based (light emitting diode) light source has been used as an experimental tool in some studies. Purpose: The main objective was to compare these two light sources emitting in the same spectral band (red from 625 to 660 nm) to promote pain relief. Material and methods: A total of 6 sessions were accomplished, being three irradiation sessions and three follow-up sessions. This single-blind study compared a control group (Placebo) and two other groups with different equipments: low laser intensity treatment (LILT) and a light emitting diode system treatment (LEDT). Results: The results showed that there is no statistical difference between LILT and LEDT groups, however, both were better than control group (p=0.01) in terms of treatment efficiency; there is no difference between the second and the third sessions for both treatment, it means that the third session was not necessary; finally, the improvement at the end of the entire research (follow up care of 30 days) was very expressive in comparison to pre-treatment situation for all teeth (p=0.01). Conclusion: LILT and LEDT were equally effective to treat dentine hypersensitivity, a 3rd treatment session was not necessary/two sessions are enough.
Resumo:
The ability of Staphylococcus aureus to develop multidrug resistance is well documented, and the antibiotic resistance showed by an increasing number of bacteria has shown the need for alternative therapies to treat infections, photodynamic therapy (PDT) being a potential candidate. The aim of this study was to determine the effect of photodynamic therapy as a light-based bactericidal modality to eliminate Staphylococcus aureus. The study investigated a technique based on a combination of light and a photosensitizer that is capable of producing oxidative species to induce a cytotoxic effect. A Staphylococcus aureus suspension was exposed to a light emitting diode (LED) emitting at 628 nm, 14.6 mW/cm(2), and energy density of 20J/cm(2), 40J/cm(2), or 60 J/cm(2) in the presence of different porphyrin concentrations (PhotogemA (R)). Three drug concentrations were employed: 12 mu l/ml, 25 mu l/ml, and 50 mu l/ml. The treatment response was evaluated by the number of bacterial colony forming units (CFU) after light exposure. The results indicated that exposure to 60 J/cm(2) eliminated 100% (10 log(10) scales) of bacteria, on average. The best PDT response rate to eliminate Staphylococcus aureus was achieved with exposure to LED light in combination with the photosensitizer at concentrations ranging from 25 mu l/ml to 50 mu l/ml. These data suggest that PDT has the potential to eliminate Staphylococcus aureus in suspension and indicates the necessary drug concentration and light fluency.
Resumo:
To evaluate the cytotoxicity of PDT (photodynamic therapy) with Photogem (R) associated to blue LED (light-emitting diode) on L929 and MDPC-23 cell cultures, 30000 cells/cm(2) were seeded in 24-well plates for 48 h, incubated with Photogem (R) (10, 25 or 50 mg/l) and irradiated with an LED source (460 +/- 3 nm; 22 mW/cm(2)) at two energy densities (25.5 or 37.5 J/cm(2)). Cell metabolism was evaluated by the MTT (methyltetrazolium) assay (Dunnet`s post hoc tests) and cell morphology by SEM (scanning electron microscopy). Flow cytometry analysed the type of PDT-induced cell death as well and estimated intracellular production of ROS (reactive oxygen species). There was a statistically significant decrease of mitochondrial activity (90% to 97%) for all Photogem (R) concentrations associated to blue LED, regardless of irradiation time. It was also demonstrated that the mitochondrial activity was not recovered after 12 or 24 h, characterizing irreversible cell damage. PDT-treated cells presented an altered morphology with ill-defined limits. In both cell lines, there was a predominance of necrotic cell death and the presence of Photogem (R) or irradiation increased the intracellular levels of ROS. PDT caused severe toxic effects in normal cell culture, characterized by the reduction of the mitochondrial activity, morphological alterations and induction of necrotic cell death.
Resumo:
Dental composite resins possess good esthetic properties, and are currently among the most popular dental restorative materials. Both organic and inorganic phases might influence the material behavior, the filler particle features and rate are the most important factors related to improvement of the mechanical properties of resin composites. Thus, the objective of this study was to evaluate the effect of three different composite resins on the polymerization process by Vickers hardness test. The samples were prepared using three different composite resins, as follow: group I-P-60 (3M/ESPE); group II-Herculite XRV (Kerr), and group III-Durafill (Heraeus-Kulzer). The samples were made in a polytetrafluoroethylene mould, with a rectangular cavity measuring 7 mm in length, 4 mm in width, and 3 mm in thickness. The samples were photo-activated by one light-curing unit based on blue LEDs (Ultrablue III-DMC/Brazil) for 20 and 40 s of irradiation times. The Vickers hardness test was performed 24 h after the photo-activation until the standardized depth of 3 mm. The Vickers hardness mean values varied from 158.9 (+/- 0.81) to 81.4 (+/- 1.94) for P-60, from 138.7 (+/- 0.37) to 61.7 (+/- 0.24) for Herculite XRV, and from 107. 5 (+/- 0.81) to 44.5 (+/- 1.36) for Durafill composite resins photo-activated during 20 s for the 1st and 2nd mm, respectively. During 40 s of photo-activation, the Vickers hardness mean values were: from 181.0 (+/- 0.70) to 15.6 (+/- 0.29) for P-60, and from 161.8 (+/- 0.41) to 11.2 (+/- 0.17) for Herculite XRV composite resins, for the 1st and 3th mm, respectively. For Durafill composite resin the mean values varied from 120.1 (+/- 0.66) to 61.7 (+/- 0.20), for the 1st and 2nd mm, respectively. The variation coefficient (CV) was in the most of the groups lower than 1%, then the descriptive statistic analysis was used. The Vickers hardness mean values for Durafill were lower than P-60 and Herculite XRV composite resins for 20 and 40 s of irradiation time. The polymerization process was greatly affected by the composition of the composite resins.
Resumo:
The aim of this study was to investigate the effectiveness of Photodynamic Therapy (PDT) using Methylene Blue (MB) as the photosensitizing compound and a Light-Emitting Diode (LED) in American cutaneous leishmaniasis (ACL). Hamsters were experimentally infected with Leishmania (Leishmania) amazonensis. After the development of the lesions in the footpad, the animals were treated with MB three times a week for 3 months. Ten minutes after each application of MB, the lesions were irradiated with LED for 1 h. The lesions were evaluated weekly by the measurement of the hamster footpad thickness. At the end of the treatment the parasitic load was quantified in the regional lymph node of the hamsters. The treatment promoted a decrease in the thickness of infected footpad (P = 0.0001) and reduction in the parasitic load in the regional lymph node (P = 0.0007) of the animals from group treated with MB + LED. PDT using MB + LED in ACL caused by L. amazonensis shows a strong photodynamic effect. This therapy is very promising, once it is an inexpensive system and the own patient can apply it in their wound and in their house without the need of technical assistance. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Different compositions of visible-light-curable triethylene glycol dimethacrylate/bisglycidyl methacrylate copolymers used in dental resin formulations were prepared through copolymerization photoinitiated by a camphorquinone/ethyl 4-dimethylaminobenzoate system irradiated with an Ultrablue IS light-emitting diode. The obtained copolymers were evaluated with differential scanning calorimetry. From the data for the heat of polymerization, before and after light exposure, obtained from exothermic differential scanning calorimetry curves, the light polymerization efficiency or degree of conversion of double bonds was calculated. The glass-transition temperature also was determined before and after photopolymerization. After the photopolymerization, the glass-transi-tion temperature was not well defined because of the breadth of the transition region associated with the properties of the photocured dimethacrylate. The glass-transition temperature after photopolymerization was determined experimentally and compared with the values determined with the Fox equation. In all mixtures, the experimental value was lower than the calculated value. Scanning electron microscopy was used to analyze the morphological differences in the prepared copolymer structures. (C) 2007 Wiley Periodicals, Inc.
Resumo:
The aim of this work was to evaluate the effect of the storage time on the thermal properties of triethylene glycol dimethacrylate/2,2-bis[4-(2-hydroxy-3-methacryloxy-prop-1-oxy)-phenyl]propane bisphenyl-alpha-glycidyl ether dimethacrylate (TB) copolymers used in formulations of dental resins after photopolymerization. The TB copolymers were prepared by photopolymerization with an Ultrablue IS light-emitting diode, stored in the dark for 160 days at 37 degrees C, and characterized with differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and Fourier transform infrared spectroscopy with attenuated total reflection. DSC curves indicated the presence of an exothermic peak, confirming that the reaction was not completed during the photopolymerization process. This exothermic peak became smaller as a function of the storage time and was shifted at higher temperatures. In DMA studies, a plot of the loss tangent versus the temperature initially showed the presence of two well-defined peaks. The presence of both peaks confirmed the presence of residual monomers that were not converted during the photopolymerization process. (C) 2009 Wiley Periodicals, Inc. J Appl Polym Sci 112: 679-684, 2009
Resumo:
Nos últimos dez anos, milhares de trabalhos foram publicados somente no desenvolvimento da técnica de eletroforese capilar (CE) e suas aplicações em ciências biológicas, química e em outras áreas. Apesar disto, muitos tópicos de pesquisa básica da CE ainda continuam sendo desenvolvidos. Algumas vantagens da CE sobre as demais técnicas de separação são marcantes, tais como: possibilidade de automação, rapidez na obtenção dos resultados e alto poder de resolução. A pequena quantidade de amostra que é necessária para uma análise é uma característica muito interessante no estudo de sistemas biológicos, sendo que normalmente são injetados no capilar, volumes de 5 a 50 nl de amostra. Por outro lado, esta reduzida quantidade de amostra utilizada, a pequena janela de detecção e as baixas concentrações dos analitos nas amostras biológicas, são fatores que desafiam os pesquisadores nesta área. Para contornar este problema diversos métodos de pré-concentração de amostra foram desenvolvidos. Neste trabalho, foi desenvolvido um método inédito de pré-concentração de amostras através de gradientes térmicos em CE. O princípio do método é concentrar o analito quando ele passa de uma zona de alta temperatura para uma zona de baixa temperatura. Um modelo teórico foi desenvolvido para auxiliar o planejamento experimental no que diz respeito à determinação das condições em que a corrida deve ser realizada (pH, tipo de tampão, temperatura) para aplicar a compressão térmica em um analito. Foi utilizado L-Lisina derivatizada com naftaleno 2,3-dicarboxialdeído (Lys/NDA) como analito modelo. Uma diferença de temperatura de 58 °C entre as duas zonas térmicas foi suficiente para comprimir em 2,5 vezes a banda da Lys/NDA em um tampão de baixo coeficiente térmico com o pH ajustado para 8,7. O método de compressão de banda por gradientes térmicos proposto neste trabalho é uma nova opção para aumentar a sensibilidade e a resolução em CE. Ao contrário dos métodos clássicos de pré-concentração, esse novo método pode ser aplicado em amostras tanto com alta ou baixa condutividade iônica, comprimir bandas de analitos aniônicos ou catiônicos e ser aplicado em corridas em solução livre ou não. Além disso, considerando que o controle de temperatura seja realizado de maneira automatizada, pode apresentar altas taxas de reprodutibilidade, além de ser de simples e de fácil aplicação, podendo ser empregado em análises de rotina. Diferentes LEDs (Light Emitting Diode) foram testado em detector por fluorescência induzida por LED. Além disso, um novo sistema de aquisição de dados e tratamento de sinal utilizando a placa de som de um PC (Personal Computer) e um amplificador Lock-in emulado por software foi montado e comparado com um sistema de aquisição de dados convencional. O equipamento de CE utilizado neste trabalho com esses componentes, apresentou uma elevada sensibilidade, na faixa de 0,5 à 1 fmol para os peptídeos e aminoácidos testados e foi superior ao sistema convencional em vários aspectos como: sensibilidade de detecção, faixa linear de detecção em concentração do analito, facilidade de operação e custo do sistema.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A PPV derivative, poly(2-methoxy,5-(n-octadecyl)-p-phenylenevinylene) (OC1OC18-PPV), has been synthesized via the Gilch route and used to fabricate Langmuir and Langmuir-Blodgett (LB) films. True monomolecular films were formed at the air/water interface, which were successfully transferred onto different types of substrate. Using UV-visible absorption, FTIR, fluorescence and Raman scattering spectroscopies we observed that the polymer molecules were randomly distributed in the LB film, with no detectable anisotropy. This is in contrast to the anisotropic LB films of a previously reported PPV derivative, poly(2-methoxy-5-n-hexyloxy)-p-phenylenevinylene (OC1OC6-PPV), which is surprising because the longer chain of OC1OC18-PPV investigated here was expected to lead to more ordered films. As a consequence of the lack of order, LB films of OC1OC18-PPV exhibit lower photoconductivity and require higher operating voltage in a polymer light-emitting diode (PLED) in comparison with LB films of OC1OC6-PPV. This result confirms the importance of molecular organization in the LB film to obtain efficient PLEDs. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)