958 resultados para D. Fracture


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study provides further developments of the evaluation procedure for J and CTOD in SE(T) fracture specimens based on plastic eta-factors and load separation analysis. Non-linear finite element analyses for plane-strain and 3-D models provide the relationship between plastic work and crack driving forces which define the eta-values. Further analyses based on the load separation method define alternative eta-values for the analyzed specimen configurations. Overall, the present results provide improved estimation equations for J and CTOD as a function of loading condition (pin load vs. clamp ends), crack geometry and strain hardening properties. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To assess the influence of cervical preparation on fracture susceptibility of roots. Material and methods: During root canal instrumentation, the cervical portions were prepared with different taper instruments: I: no cervical preparation; II: #30/.08; III: #30/.10; IV: #70/.12. The specimens were sealed with the following filling materials (n = 8), A: unfilled; B: Endofill/gutta-percha; C: AH Plus/gutta-percha; D: Epiphany SE/Resilon. For the fracture resistance test, a universal testing machine was used at 1 mm per minute. Results: anova demonstrated difference (P < 0.05) between taper instruments with a higher value for group I (205.3 +/- 77.5 N) followed by II (185.2 +/- 70.8 N), III (164.8 +/- 48.9 N), and IV (156.7 +/- 41.4 N). There was no difference (P > 0.05) between filling materials A (189.1 +/- 66.3 N), B (186.3 +/- 61.0 N), C (159.7 +/- 69.9 N), and D (176.9 +/- 55.2 N). Conclusions: Greater cervical wear using a #70/.12 file increased the root fracture susceptibility, and the tested filling materials were not able to restore resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work provides a numerical and experimental investigation of fatigue crack growth behavior in steel weldments including crack closure effects and their coupled interaction with weld strength mismatch. A central objective of this study is to extend previously developed frameworks for evaluation of crack clo- sure effects on FCGR to steel weldments while, at the same time, gaining additional understanding of commonly adopted criteria for crack closure loads and their influence on fatigue life of structural welds. Very detailed non-linear finite element analyses using 3-D models of compact tension C ( T ) fracture spec- imens with center cracked, square groove welds provide the evolution of crack growth with cyclic stress intensity factor which is required for the estimation of the closure loads. Fatigue crack growth tests con- ducted on plane-sided, shallow-cracked C ( T ) specimens provide the necessary data against which crack closure effects on fatigue crack growth behavior can be assessed. Overall, the present investigation pro- vides additional support for estimation procedures of plasticity-induced crack closure loads in fatigue analyses of structural steels and their weldments

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Compared with other mature engineering disciplines, fracture mechanics of concrete is still a developing field and very important for structures like bridges subject to dynamic loading. An historical point of view of what done in the field is provided and then the project is presented. The project presents an application of the Digital Image Correlation (DIC) technique for the detection of cracks at the surface of concrete prisms (500mmx100mmx100mm) subject to flexural loading conditions (Four Point Bending test). The technique provide displacement measurements of the region of interest and from this displacement field information about crack mouth opening (CMOD) are obtained and related to the applied load. The evolution of the fracture process is shown through graphs and graphical maps of the displacement at some step of the loading process. The study shows that it is possible with the DIC system to detect the appearance and evolution of cracks, even before the cracks become visually detectable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relatively young discipline of astronautics represents one of the scientifically most fascinating and technologically advanced achievements of our time. The human exploration in space does not offer only extraordinary research possibilities but also demands high requirements from man and technology. The space environment provides a lot of attractive experimental tools towards the understanding of fundamental mechanism in natural sciences. It has been shown that especially reduced gravity and elevated radiation, two distinctive factors in space, influence the behavior of biological systems significantly. For this reason one of the key objectives on board of an earth orbiting laboratory is the research in the field of life sciences, covering the broad range from botany, human physiology and crew health up to biotechnology. The Columbus Module is the only European low gravity platform that allows researchers to perform ambitious experiments in a continuous time frame up to several months. Biolab is part of the initial outfitting of the Columbus Laboratory; it is a multi-user facility supporting research in the field of biology, e.g. effect of microgravity and space radiation on cell cultures, micro-organisms, small plants and small invertebrates. The Biolab IEC are projects designed to work in the automatic part of Biolab. In this moment in the TO-53 department of Airbus Defence & Space (formerly Astrium) there are two experiments that are in phase C/D of the development and they are the subject of this thesis: CELLRAD and CYTOSKELETON. They will be launched in soft configuration, that means packed inside a block of foam that has the task to reduce the launch loads on the payload. Until 10 years ago the payloads which were launched in soft configuration were supposed to be structural safe by themselves and a specific structural analysis could be waived on them; with the opening of the launchers market to private companies (that are not under the direct control of the international space agencies), the requirements on the verifications of payloads are changed and they have become much more conservative. In 2012 a new random environment has been introduced due to the new Space-X launch specification that results to be particularly challenging for the soft launched payloads. The last ESA specification requires to perform structural analysis on the payload for combined loads (random vibration, quasi-steady acceleration and pressure). The aim of this thesis is to create FEM models able to reproduce the launch configuration and to verify that all the margins of safety are positive and to show how they change because of the new Space-X random environment. In case the results are negative, improved design solution are implemented. Based on the FEM result a study of the joins has been carried out and, when needed, a crack growth analysis has been performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’accoppiamento articolare in ceramica è sempre più utilizzato in chirurgia protesica dell’anca per le sue eccellenti proprietà tribologiche. Tuttavia la fragilità della ceramica è causa di fallimenti meccanici. Abbiamo quindi condotto una serie di studi al fine di individuare un metodo efficace di diagnosi precoce del fallimento della ceramica. Abbiamo analizzato delle componenti ceramiche espiantate e abbiamo trovato un pattern di usura pre-frattura che faceva supporre una dispersione di particelle di ceramica nello spazio articolare. Per la diagnosi precoce abbiamo validato una metodica basata sulla microanalisi del liquido sinoviale. Per validare la metodica abbiamo eseguito un agoaspirato in 12 protesi ben funzionanti (bianchi) e confrontato i risultati di 39 protesi con segni di rottura con quelli di 7 senza segni di rottura. Per individuare i pazienti a rischio rottura i dati demografici di 26 pazienti con ceramica rotta sono stati confrontati con 49 controlli comparabili in termini demografici, tipo di ceramica e tipo di protesi. Infine è stata condotta una revisione sistematica della letteratura sulla diagnosi della rottura della ceramica. Nell’aspirato la presenza di almeno 11 particelle ceramiche di dimensioni inferiori a 3 micron o di una maggiore di 3 micron per ogni campo di osservazione sono segno di rottura della ceramica. La metodica con agoaspirato ha 100% di sensibilità e 88 % di specificità nel predire rotture della ceramica. Nel gruppo delle ceramiche rotte è stato trovato un maggior numero di malposizionamenti della protesi rispetto ai controlli (p=0,001). Il rumore in protesi con ceramica dovrebbe sollevare il sospetto di fallimento ed indurre ad eseguire una TC e un agoaspirato. Dal confronto con la letteratura la nostra metodica risulta essere la più efficace.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Obturator anterior hip dislocation is very rare. Poor results are described in patients with additional large transchondral fractures and treatment of these injuries remains challenging. Appropriate treatment recommendations are missing in the literature. This case report introduces surgical hip dislocation for osteochondral autograft transplantation with graft harvest from the nonweightbearing area of the head-neck junction as a salvage procedure in a large femoral head defect. We report the treatment and outcome of a 48-year-old man who sustained an anterior dislocation of the left hip after a motorcycle accident. After initial closed reduction in the emergency room, imaging analysis revealed a large osteochondral defect of the femoral head within the weightbearing area (10 × 20 mm, depth: 5 mm). The hip was exposed with a surgical hip dislocation using a trochanteric osteotomy. An osteochondral autograft was harvested from a nonweightbearing area of the femoral head and transferred into the defect. The patient was prospectively examined clinically and radiologically. Two years postoperatively, the patient was free of pain and complaints. The function of the injured hip was comparable to that of the contralateral, healthy hip and showed satisfying radiologic results. Surgical hip dislocation with a trochanteric flip osteotomy is a simple, one-step technique that allows full inspection of the hip to treat osteochondral femoral defects by osteochondral transplantation. The presented technique, used as a salvage procedure in a large femoral head defect, yielded good clinical and satisfying radiologic outcomes at the midterm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Vitamin D is essential for calcium metabolism as well as for fracture prevention, and a recent review suggested that the optimal serum 25(OH)D lies in the region of 50-80 nmol L-1 (20-32 ng mL-1). A high prevalence of inadequacy has been reported in many studies but the prevalence of inadequacy amongst women with osteoporosis in different regions of the world has not been well characterized. SETTING AND SUBJECTS: A multinational study of 18 countries at various latitudes (range 64N-38S) was conducted in 2004 and 2005 to determine the average levels of serum 25(OH)D and the prevalence of vitamin D inadequacy. A total of 2606 postmenopausal women with osteoporosis (low bone mineral density, history of fragility fracture) seeking routine medical care were enrolled and serum 25(OH)D levels were measured at a single laboratory visit. RESULTS: Mean serum 25(OH)D level was 26.8 ng mL-1 (SE 0.3) and ranged from 7 to 243 ng mL-1. Regional mean values were highest in Latin America (29.6 ng mL-1, SE 0.6) and lowest in the Middle East (20.4 ng mL-1, SE 0.5). Overall, 64% of women had serum levels<30 ng mL-1. Serum parathyroid hormone reached a nadir at serum 25(OH)D levels>35 ng mL-1. In nonequatorial countries, women recruited during the winter months had somewhat lower serum 25(OH)D levels than those recruited during the summer months in some, but not all, countries. CONCLUSIONS: Low levels of serum 25(OH)D are common amongst women with osteoporosis. The results underscore the value of assuring vitamin D adequacy in these women.