977 resultados para Chumaceira Axial de Esmagamento de Película
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
The substitution of steel as a raw material in the production of axial pistons for pressure washers by polyphthalamide, polytetrafluoroethylene and glass fiber-based composite was studied. The new production process with composite consists of only two steps, while the production of the steel piston is to comprise of thirteen steps. This replacement would result in an estimated reduction of 80% of water consumption, 83% of electricity consumption, 73% of the total cost and 88% of the final mass. With regard to the main mechanical properties required for the end product, the composite was found to withstand the critical axial loads and it shows acceptable wear resistance in an environment without lubrication, an additional advantage of this replacement. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.
Resumo:
O objetivo nesta pesquisa consiste em fazer um trabalho de prevenção junto às instituições APAE (Associação de Pais e Amigos de Excepcionais) e ASIN (Associação de síndrome de Down), ambas de São José dos Campos e ASPAD (Associação de Pais e Amigos de síndrome de Down) de Jacareí, orientando e avaliando sobre a presença ou não da instabilidade atlanto-axial (IAA), assim como verificar a prevalência dessa anormalidade nesses indivíduos. Foram convidados a participar do projeto todos os indivíduos das três instituições de assistência à SD, tendo formado uma amostra com 68 indivíduos, com idades entre 2 a 34 anos, sendo 39 do sexo masculino e 29 do feminino. Foram realizadas radiografias da coluna cervical nas posições de extensão, flexão e neutra, para as quais todos os responsáveis assinaram termo de consentimento. A verificação da IAA foi feita pela análise da distância atlanto-odontóide (DAO), utilizando o programa Radiocef, com uma ferramenta criada para isso. A DAO foi analisada nas três incidências, e era considerada a presença de IAA desde que o indivíduo apresentasse valores ?4,5mm em pelo menos uma dessas posições. Após a realização dos testes estatísticos e análise dos resultados, concluímos que a prevalência de IAA foi de 22,1% dos indivíduos, com valores DAO entre 4,5 e 8,83mm, tendo sido mais prevalente nos indivíduos do sexo masculino do que feminino, assim como nas crianças do que nos jovens e adultos. Foi possível verificar também que, a posição de flexão apresentou maior prevalência de IAA, mas que ela não deve sobrepor às posições de extensão e neutra, pois pode omitir casos ausentes em flexão, mas presentes nas outras posições. Dessa forma, foi realizado o trabalho de prevenção com a avaliação da IAA por meio da realização dos exames radiográficos em que os laudos... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
In the last years, environmental issues are being gradually addressed because of awareness regarding the limitation of natural resources for the maintenance of life on Earth, and the role played by the media in reporting on various issues that are related to the theme. In the industrial sector, this topic becomes ever more present in its planning. With the increase of production activities, the generation of waste causes many complications, both in industry and in the environment. For this reason laws and rules were created so that such problems are minimized, thus causing less impact on the environment. In this work was a study of the possible environmental impacts in a soybean crushing industry, situated in the city of Osvaldo Cruz, São Paulo state, detailing the sources and impacts of waste generation, and associate them relevant laws. From this, measures were proposed measures of adequacy involving compliance with commitments to environmental agencies, relevant requests of buyers and / or suppliers and improving environmental performance
Resumo:
When materials for application in aircraft structural components are studied, it must be considered that they will be submitted to cyclic loading, and this is an important parameter to design the study in fatigue life of the materials. Whereas, for example, a landing gear operation, the study of fatigue life and corrosion in the materials used in it is essential, especially when you want to use new techniques for surface treatments. The objective is to study the influence of surface treatment of immersion ion implantation nitrogen plasma, in axial fatigue of Stainless steel 15-5 PH in 39-42 HRC condition. Stainless steel 15-5 PH was tested in axial fatigue and corrosion in salt spray. It was also performed microindentation tests, optical microscopy for microstructural analysis and scanning electron microscopy for fractographic analysis. It was observed that the 3IP had no effect on the thickness of the material and not the hardness of it, and still provided a significant increase in fatigue life of the material