1000 resultados para Centrais de abastecimento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present research has the purpose of planning the management of the water resources of the Seridó River watershed, in the state of Rio Grande do Norte, Brazil. It has an emphasis on the amount of surface water available in this region, to provide a sustainable water supply. Based on data and information collected from public departments responsible for the management of the water resources of the Rio Grande do Norte state, well as on researches related to water resources , a watershed balance was done, and the results suggested the transposition of the waters from the Piranhas-Açu river watershed taken from the Oiticica and Armando Ribeiro Gonçalves reservoirs, integrated with the construction of 2 hidroelectrical plants and 2 elevation stations, to pump the amount of water needed to the expected demand in some public dams of the region until 2020. So, with the use of the surface water potential that exists in the region, it was demonstrated that, on the contrary of the public policies implemented in the past and in the current by the federal and state realm, it is possible to supply the currently water demands and also the future ones, in a sustainable way, without the need of importing outter water to the respective watershed. Finally, it was proposed the implementation of the Water Resources Plan in the Seridó region WRPS, aiming at providing an auto-sustainable development by significantly diminishing the effects of the dry seasons in that region, by considering the economic, social and environmental sustainability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research study deals with the production and distribution of drinking water with quality and safety in order to meet the needs of the Man. Points out the limitations of the methodology for assessing water quality in use today. Approaches the recommendations of the World Health Organization (WHO) for adoption, by the companies responsible for producing and distributing water, of assessment methodologies and risk management (HACCP), in order to ensure the quality and safety of water drinking. Suggests strategies for implementing the plan for water safety plan. Uses the process of water production, composed by Maxaranguape river basin, the water treatment plant and distribution system, which is part of the Plan for Expansion of the Supply System of Natal, as case study. The results, it was possible to devise strategies for implementation of the Water Safety Plan (WSP), which comprises the following steps: a) a preliminary stage. b) assessment system. c) process monitoring. d) management plan and e) validation and verification of the PSA. At each stage are included actions for its implementation. The implementation of the PSA shows a new type of water production, in which the fountain as a whole (watershed and point of capture), the Water Treatment Plant (WTP) and distribution, shall compose the production process, over which to build quality and safety of the final product (drinking water)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The groundwater quality has been compromised as a result of the intensification of human activities over the years. Groundwater contamination by nitrate is one of the effects of this degradation, a socio-environmental problem that affects many regions of the world and particular the city of Natal (RN). Developing techniques for nitrate removal in water is intended to eliminate or reduce the concentration of this compound, and those that involve biological processes have produced economic and environmental advantages. This study proposes a technology for biological removal of nitrate in water supply for humans, using the endocarp s coconut as a carbon source and bacteria support. The experiments were performed in pilot scale anoxic, testing different areas of the substrate surface. Results showed high rates nitrate removal during the monitoring period, noting the occurrence of denitrification after the beginning of system operation. The best performance was achieved in the treatment system containing substrate surface area increased, indicating that the decrease in the endocarp size contributed to increased bacterial activity, improving the ability to remove nitrate. About the quality analyzed aspects of water, it was found that the proposed technology has the potential water use for human consumption

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dengue fever is an infectious disease that causes thousands of deaths each year in Brazil and other tropical countries. This work demonstrates that the irregularity in the supply of water by public water supply systems is a major factor that contributes to the proliferation of breeding sites of the mosquito that transmits dengue, due to the impossibility of removing water storage tanks. 31 points in the water supply network in thirteen districts of Natal, Brazil, were monitored by the installation of pressure gauges type Datalogger. The data about pressure showed deficiency in water supplies in many neighborhoods, forcing residents to accumulate water in tanks at ground level. In addition, It was observed that in neighborhoods with regular water supply, Infestation Index per type of container (ITR) of type A2 (Deposit ground level) was 0.00% and where there were failures in the supply of water , the ITR was high (above 50%). We believe that policies to combat dengue in Brazil should be reassessed so that more resources can be directed to the improvement of water supply systems and supply companies should be blamed for the problem too

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central giant cell lesion (CGCL) and peripheral giant cell lesion (PGCL) of the jaws have a distinct clinical behavior, although they share histopathologic features. It is still unclear whether these clinical differences are supported by a distinct pattern of immunoexpression of markers for multinucleated giant cells (GC) and mononuclear cells (MC). The purpose of this study was to compare the immunohistochemical expression of VEGF, MMP-9 in CG and MC and measure the vascularization by vWF to check whether there are differences in expression of these biomarkers between CGCL and PGCL. Paraffin wax blocks of 20 cases of LCCG and 20 LPCG were retrieved. MMP-9 immunoreactivity was greater in the CM of PGCL compared to VEGF (p<0.05). VEGF expression was greater in the CM of CGCL compared to PGCL (p<0.05) and it was greater in the overall expression of CGCL compared to PGCL (p<0.05). Vascularity was quantified by microvascular counting (MVC). MVC was greater in the PGCL compared CGCL (p<0.05). MMP-9 showed a greater tendency of expression in CGCL, though was not significant (p>0.05). We tested correlation between the proteins studied in each group and found a significant negative correlation between VEGF and vWF in CGCL (p<0.05). These results suggest that there are differences in the expression of VEGF in CM and overall expression between the lesions, although no statistically significant difference in the overall expression of the MMP-9. Then, there was a trend in increased expression of MMP-9 and VEGF in CGCL, possibly by the involvement of both proteins in osteoclastogenesis. Additionally, the results of this study indicate a higher degree of vascularization in PGCL compared to CGCL, fact that can be directly linked to the reactive nature of the PGCL, where the inflammatory process with its rich angiogenesis contributes significantly to these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Giant Cell Lesions, both the Central Giant Cells Lesions (CGCL) as the Peripheral Giant Cells Lesions (PGCL), correspond to a group of oral lesions that are histologically similar entities; however they show a variable clinical behaviour. The purpose of this study was to compare the immunohistochemical expression of bone resorption factors RANK (Receptor Activator of Nuclear Factor kappa B), RANKL (Receptor Activator of Nuclear Factor kappa B Ligand) and OPG (Osteoprotegerin) between CGCL and PGCL. Additionally, these bone resorption factors were examined in terms of aggressiveness of these lesions. The sample consisted of 61 cases, 30 cases of PGCL and 31 CGCL (16 non-aggressive and 15 aggressive). The analysis was performed by quantification of mononuclear cells (MO) and giant multinucleated cells (CG) immunopositive to anti-RANK, anti-RANKL and anti-OPG antibodies in 10 fields. Moreover, according to the proportion between the amount of cells positive for RANKL and OPG, the cases were categorized into: RANKL>OPG, OPG>RANKL e RANKL=OPG. CGCL showed a higher amount of MO (p=0.002) and total cells (p=0.003) both positives to RANKL compared with the PGCL. Additionally, the CGCL revealed a significant association with the ratio of RANKL>OPG (p=0.001). Analysis of the bone resorption factors revealed no significant differences between aggressive and non-aggressive CGCL (p>0.05). It was observed a positive correlation between the markers themselves, and a negative correlation between lesion size and quantity of OPG positive MO cells (p=0,004) and total cells (p=0,009). Through these results, we suggest that the greatest CGCL resorptive potential compared to the PGCL, may have occurred to the high expression of RANKL. Furthermore differences in the biological behavior of aggressive and non-aggressive CGCL appear to be related to the expression of these bone resorption factors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A emergência na necessidade de se manejar os resíduos sólidos urbanos leva as administrações públicas em países centrais e periféricos a utilizarem modelos de gestão de resíduos bastante similares. A gestão dos resíduos nos países centrais é caracterizada pela eficiência na execução dos serviços (limpeza, coleta, transporte e destino final), uso de aparatos tecnológicos na execução de ditos serviços e forte tradição na separação dos materiais recicláveis a ser destinados para a reciclagem. Nos países periféricos, a gestão tradicional (coletar e descartar resíduos em lixões à céu aberto) vem sendo substituída pela gestão moderna, sobressaindo-se o controle dos resíduos em detrimento das estratégias de prevenção. Também, destaca-se a presença de trabalhadores informais que coletam e separam materiais, destinando-os à reciclagem. A partir do levantamento à referência bibliográfica especializada e na consulta a documentos oficiais e produzidos por entidades diversas, o presente artigo analisa as similitudes na gestão dos resíduos sólidos em países centrais e periféricos. A busca pela modernização nos serviços dos resíduos sem levar em conta as recomendações de documentos como a Agenda 21 caracteriza a gestão dos resíduos em países centrais e periféricos pelo ambientalismo econômico, no qual as ações de controle dos resíduos são justificadas pelos aspectos ambientais e sociais dessa gestão

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming to know the influence of the pluviometric precipitation over the physical chemical and bacteriological characteristics of the water coming from three sources of public supply, and to verify the probable origin of faecal contamination, tests of total coliforms, faecal coliforms, faecal streptococci and mesophilic microorganisms, as well as the determination of pH, temperature and turbidity of 156 water samples were done. The samples were taken from a stream, a drain and an artesian well, located in the city of Jaboticabal, SP, Brazil. The results obtained showed that the occurrence of pluviometric precipitation determined a significant increase of the number of total coliforms in the water samples from the stream. The use of the ratio CF/EF, indicate the probable origin of the faecal contamination only in the samples of the water coming from the stream, which were defined as being of human origin. In relation to the physical-chemical composition it was noticed that the influence of the pluviometric precipitation over the turbidity appeared to be higher and significant in the samples of water of the stream.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It may be difficult for small and medium cities to obtain information about the fluoride content of public water, because of the lack of equipments and technicians. This study aimed to analyze the fluoride levels of the water supplied by the public treatment stations of 40 cities situated in the northwest region of São Paulo State, during a period of 6 months, to verify if fluoridation occurs in a continuous manner and if the fluoride levels are within the recommended. Maps of the water distribution system were obtained from the water treatment companies and utilized to randomize the addresses of the collection sites, so that they included all regions with treated water sources. One water sample by month was collected and analyzed in duplicate using an ion-specific-electrode. Samples with 0.6 to 0.8 mgF/L were considered acceptable. In the 38 cities that regularly provided the samples in the 6 months of the study, water from 144 collection sites was collected and a total of 864 samples were analyzed, of which 61.81 percent were classified as unacceptable. It was observed that 33 cities performed fluoridation but in 78.79 percent of these cities there were variations in the fluoride level among the sites and in the same site during the period of study. One can conclude that most of these cities do not control the fluoride levels in the public water, since fluoridation occurs in a discontinuous manner and in most of the situations not within the recommended concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses on the drinking-water fluoridation process in Araçatuba region water supply systems by means of 5.157 fluoride concentration data from 2001 to 2005. These data were studied based on the water source, the administration and the structure of the water supply system, according to the population of the county and the type of management. Almost half of samples did not comply the fluoridation standard and the higher compliance was verified in the water supply systems operated by Sabesp (69%), followed by the group of Large counties (52%), statistically similar to the Medium ones (51.4%), and better than the Small ones (28%). The systems with surface intakes showed statistically higher performance in the compliance to the standard (60%) compared to the ones that use groundwater (42.9%). In this last group, those that explore the Guarani aquifer were superior (52.3%) than the others (46.6%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geoelectrical methods have been widely used in research involving the evaluation and monitoring of areas with environmental risk. This paper presents the results of applying the Electrical Resistivity method by electrical profiling technique to investigate the fuel presence in soil and groundwater proceeding in station gas, located in an urban area Caçapava do Sul (RS), on soil in situ, from modification of Caçapava granite. The results suggest an association between low resistivity anomalies zone with potentially degraded from underground tanks worthless on the form of free phase, now represented as residual phase. The results of the model inversion are consistent with the standards expected for hydrocarbons present in the saturated zone. The electrical resistivity method proved to be an important tool for assessment and environmental monitoring in conjunction with direct methods of investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA