1000 resultados para 60-456A


Relevância:

20.00% 20.00%

Publicador:

Resumo:

目的 重离子和高剂量率6 0 Coγ射线照射离体人血建立染色体畸变的剂量 效应曲线 ;比较重离子1 2 C照射与6 0 Coγ射线照射诱发染色体畸变的相对生物效能。方法 重离子1 2 C和6 0 Coγ射线照射离体人血 ,吸收剂量率为 3Gy min ,吸收剂量为 1 0~ 8 0Gy。主要记录染色体型畸变的非稳定性畸变 ,对双着丝粒体和着丝粒环做曲线拟合 ,并检验回归系数的显著性和曲线的拟合度。结果 重离子1 2 C和6 0 Coγ射线照射离体血诱发的染色体畸变 (双 +环 ) ,在 0~ 8Gy范围内 ,呈良好的剂量 效应关系。1 2 C离子诱发染色体畸变的RBE值是不恒定的 ,它随吸收剂量增加而减少 ,在 0 3~ 8 0Gy范围内 ,RBE值 (Dγ Dc)从 2 6 2到 1 0 0 ,平均 1 5 8。结论 1 2 C离子对6 0 Coγ射线照射诱发染色体畸变 ,在照射剂量较低时 ,有较高的生物效应。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

目的 比较重离子束1 2 C6+对60 Coγ射线照射人离体血诱发淋巴细胞微核的效应。方法 用60 Coγ射线和地面加速器产生的重离子1 2 C6+(平均LET为 36 70keV μm) ,不同剂量照射离体人血 ,用CB微核法观察双核淋巴细胞的微核 ,计算重离子束1 2 C6+对60 Coγ射线的相对生物效能。结果 在 0~ 6Gy剂量范围内 ,重离子束1 2 C6+对60 Coγ射线的相对生物效能在 4 1 9~ 1 78之间 ,平均为 2 56。结论 重离子束1 2 C6+比60 Coγ射线有更高的生物效应

Relevância:

20.00% 20.00%

Publicador:

Resumo:

用 Raman散射和 XPS技术分析了能量为几百 ke V到几百 Me V的多种离子在 C60 薄膜中引起的辐照效应 .分析结果表明 ,在低能重离子辐照的 C60 薄膜中 ,其晶态向非晶态的转变过程是由核碰撞主导的 .在快离子 (1 2 0 ke V的 H离子和 1 71 .2 Me V的 S离子 )辐照的情况下 ,电子能损起主导作用 .发现在 H离子辐照过程中 ,电子能损有明显的退火效应 ,致使 C60 由晶态向非晶态转变的过程中 ,经历了一个石墨化的中间过程 ;而在 S离子辐照的情况下 ,电子能损的破坏作用超过了退火效应 ,因此 ,在 C60 由晶态向非晶态转变的过程中 ,无石墨化的中间过程

Relevância:

20.00% 20.00%

Publicador:

Resumo:

用 Raman(拉曼)散射技术分析了 120keV的 H, Ar和 Fe离子在 C60薄膜中引起的辐照效应,主要指由晶态向非晶态的转变.分析结果表明,在Fe和Ar离子辐照的C60薄膜中,核碰撞主导了由晶态向非晶态的转变过程.而在H离子辐照的情况下,电子能损起主导作用,并发现在H离子辐照过程中,电子能损有明显的退火效应,致使由晶态向非晶态转变的过程中,经历了一个石墨化的中间过程。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-induced fragmentation of C-60 has been studied using a time-of-flight mass spectrometric technique. The average kinetic energies of fragment ions C-n(+) (n <= 58) have been extracted from the measured full width at half maximum (FWHM) of ion beam profiles. The primary formation mechanism of small fragment ion C-n(+) (n < 30) is assumed to be a two-step fragmentation process: C60 sequential decay to unstable C-30(+) ion and the binary fission of C-30(+). Considering a second photo absorption process in the later part of laser pulse duration, good agreement is achieved between experiment and theoretical description of photoion formation. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiation has been widely reported to damage organisms by attacking on proteins, nucleic acid and lipids in cells. However, radiation hormesis after low-dose irradiation has become the focus of research in radiobiology in recent years. To investigate the effects of pre-exposure of mouse brain with low-dose C-12(6+) ion or Co-60 gamma (gamma)-ray on male reproductive endocrine capacity induced by subsequent high-dose irradiation, the brains of the B6C3F(1) hybrid strain male mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy as challenging irradiation dose at 4 h after pre-exposure. Serum pituitary gonadotropin hormones, follicle-stimulating hormone (FSH) and luteinizing hormone (LH), testosterone, testis weight, sperm count and shape were measured on the 35th day after irradiation. The results showed that there was a significant reduction in the levels of serum FSH, LH, testosterone, testis weight and sperm count, and a significant increase in sperm abnormalities by irradiation of the mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray. Moreover, the effects were more obvious in the group irradiated by C-12(6+) ion than in that irradiated by Co-60 gamma-ray. Pre-exposure with low-dose C-12(6+) ion or Co-60 gamma-ray significantly alleviated the harmful effects induced by a subsequent high-dose irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ovaries of Kun-Ming strain mice (3 weeks) were irradiated with different doses of C-12(6+) ion or Co-60 gamma-ray. Chromosomal aberrations were analyzed in metaphase II oocytes at 7 weeks after irradiation. The relative biological effectiveness (RBE) of C C-12(6+) ion was calculated with respect to Co-60 gamma-ray for the induction of chromosornal aberrations. The C-12(6+) ion and Co-60 gamma-ray dose-response relationships for chromosomal aberrations were plotted by linear quadratic models. The data showed that there was a dose-related increase in frequency of chromosomal aberrations in all the treated groups compared to controls. The RBE values for C-12(6+) ions relative to (CO)-C-60 gamma-rays were 2.49, 2.29, 1.57, 1.42 or 1.32 for the doses of 0.5, 1.0, 2.07 4.0 or 6.0 Gy, respectively. Moreover, a different distribution of the various types of aberrations has been found for C-12(6+) ion and Co-60 gamma-ray irradiations. The dose-response relationships for C-12(6+) ion and (CO)-C-60 gamma-ray exhibited positive correlations. The results from the present study may be helpful for assessing genetic damage following exposure of immature oocytes to ionizing radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thick natural uranium target was bombarded with a 60 MeV/u O-18 beam. The neutron-rich isotope Ra-230 as the target residue was produced through the multinucleon transfer reaction (U-238-4p-4n). The barium and radium fraction as BaCl2 precipitate were radiochemically separated first from the mixture of uranium and reaction products. Then, the radium fraction was separated from BaCl2 precipitate by using cation exchange technique. The gamma-ray spectra of the Ra fraction were measured using an HPGe detector. The production cross sections of Ra-230 were obtained by a combination of the radiochemical separation technique and off-line gamma-ray spectroscopy. The cross section of Ra-230 has been determined to be 66 +/- 20 mu b.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neutron-rich target-like isotope Th-236 has been produced in the U-238-2p multinucleon transfer reaction between a 60 MeV/u O-18 beam and natural U-238 targets. The activities of thorium were determined after radiochemical separation of Th from the mixture of uranium and reaction products. The Th-236 isotope was identified by the characteristic gamma-rays of 642.2, 687.6 and 229.6 keV. The production cross section of Th-236 was determined to be 250 +/- 50 mu b.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brain of the Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy of 12C6+ ion or Co-60 gamma-ray as challenging irradiation dose at 4 h after per-exposure. Body weight and serum growth hormone (GH) concentration were measured at 35th day after irradiation. The results showed that irradiation of mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray significantly diminished mouse body weight and level of serum GH. The relative biological effectiveness values of a 2 Gy dose of C-12(6+) ion calculated with respect to Co-60 gamma-ray were 1.47 and 1.34 for body weight and serum GH concentration, respectively. Pre-exposure with a low-dose (0.05 Gy) of C-12(6+) ion or Co-60 gamma-ray significantly alleviated reductions of mouse body weight and level of serum GH induced by a subsequent high-dose (2 Gy) irradiation. The data suggested that low-dose ionizing irradiation can induce adaptive hormetic responses to the harmful effects of pituitary by subsequent high-dose exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

为了研究低速高电荷态离子在C60薄膜中引起的势效应,用能量为200keV的高电荷态Xen+(n=3,10,13,15,17,20,22,23)离子辐照了C60薄膜。用原子力显微镜(AFM)和Raman散射技术分析了辐照过程中高电荷态Xen+离子所储存势能在C60薄膜中引起的效应,即势效应。AFM分析结果表明,辐照C60薄膜的表面粗糙度随辐照Xen+离子电荷态(即势能)的增加而减小,揭示了势效应的存在。而Raman分析结果表明,由于Xe离子的动能远大于其所储存的势能,因此,尽管有表面势效应的影响,但在Raman分析的深度范围内,弹性碰撞还是主导了C60薄膜的损伤过程。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiation effect in C-60 films induced by 170 keV B ion was investigated by means of Fourier transform infrared (FTIR) and Raman spectroscopies. The damage cross section sigma and the effective damage radius R are deduced from the experimental data of all four IR active modes and evident four Raman active modes of C-60 molecule. The differences on irradiation sensitivity and structural stability of the different active modes of C-60 molecule are compared. The results indicate that T-1u (4) of infrared active mode and A(g) (1) of Raman active mode are most sensitive for B ion irradiation. On the other hand T-1u (2) of infrared active mode and H-g (3) of Raman active mode are comparatively stable under B ion irradiation. (C) 2010 American Institute of Physics. [doi:10.1063/1.3512968]