954 resultados para 240606 Física médica


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The contribution of the total dose due to deposition of secondary energy particles caused by nuclear inelastic processes (n, 2H, 3H, 3He and  ) in proton therapy is an opened problem and in discussion. In the calculations of plans implemented for routine treatment, the paid dose is calculated whereas that the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered, mainly due to the difficulty of processing targets consisting of various materials. In this sense, there are only estimates for pure materials or simple composition (water, for example).This work presents the results of simulations by the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) of the contribution to the total dose of secondary particles. The study was implemented in a cylindrical phantom composed by compact bone, for monochromatic beams of protons between 100 and 200 MeV with pencil beam form

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The teaching of hearing physiology requires an knowledge integration of Human Anatomy, Biophysics, more precisely Bioacoustics and Bioelectrogenesis, as well as Neurophysiology. Students present difficulty to build knowledge about functional mechanisms of sound conduction and sensory transduction, especially if the elements are not visible forms, as the middle and inner ear structures. To make the teaching about hearing physiology and sensory perception easier, was produced a set of didactical materials about the subject. At first, a resin model that faithfully describes the anatomical relationship of the ossicles with the tympanic membrane was developed. Subsequently, a second model that, besides illustrates the mechanism of acoustic impedance overcoming, also reveals how acoustic sensorial transduction occurs in inner ear, was designed and produced. In the third didactical model, are visualized, through students interaction, areas of the cerebral cortex that interpret the different sensory modalities. In addition, were created three educational videos about hearing problems and a site on Human Hearing Physiology, available on Institute of Biosciences website. The results of this course conclusion monograph are presented in the form of articles that were submitted to Journal Physics in the School and the Journal of the Nucleus of Teaching

Relevância:

80.00% 80.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stem cells are defined as cells capable of self-renewal and differentiation into specialized cells when submited to external signalings in the enviroment. Among adult stem cells, mesenchymal cells occupy an important position because they can differentiate into mesodermal cells such as osteoblasts, adipocytes and chondrocytes. Cell therapy consists in the use of mesenchymal stem cells (MSC) in the treatment of degenerative diseases and harmed tissue reconstruction. Due to the longstanding and costly procedure for cultivation of MSC, it was proposed the use of low power light sources, such as light emitting diodes (LED), to optimize these factors. Recent works have shown a series of results from the influence of LED light on biological tissues such as increased rate of cell proliferation, increased RNA, DNA and ATP synthesis rate. The purpose of this study is to compare the biomodulator effect of LED light set at wavelengths 630nm ± 10nm and 805nm ± 10nm on the mesenchymal stem cells proliferation. For this, the mesenchymal stem cells culture adopted the procedure used in the Departament of Animal Reproduction and Veterinary Radiology of the Faculty of Veterinary Medicine and Animal Sciences of Botucatu. MSC were obtained from an adult horse bone marrow, and isolated by density gradient separation, with the FICOLL reagent and by centrifugation. The pellet containing the stem cells was removed and these were placed in low glucose DMEM culture medium, containing 10% fetal calf serum and antibiotics. The material was observed daily by inverted microscopy for monitoring the progression of the cells and subsequently the amount of cells were counted in a Neubauer counting chamber. The amount of MSC was obtained by cell culture seeded in 24 wells culture plate and segregated into three distinct groups: Group 1 was irradiated with wavelength set at 630nm ± 10 nm, Group... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work was developed starting the study of traditionals mathematical models that describe the epidemiology of infectious díseases by direct or indirect transmission. We did the classical approach of equilibrium solutions search, its analysis of stability analytically and by numerical solutions. After, we applied these techniques in a compartimental model of Dengue transmission that consider the mosquito population (susceptible vector Vs and 'infected vector VI), human population (suseeptíble humans S, infected humans I and recovered humans R) and just one sorotype floating in this population. We found the equilibrium solutions and from their analises, it was possible find the reprodution rate of dísease and which define if the disease will be endemic or not in the population.- ext, we used the method described a..~, [1] to study the infíuence of seasonalíty at vírus transmission, when it just acts on one of rates related with the vector. Lastly, we made de modeling considering the periodicity of alI rates, thereby building, a modeI with temporal dependence that permits to study periodicity of transmission through of the approach of parametrical ressonance and genetic algorithm

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experimental study in dogs was accomplished to evaluate impedances at the acupuncture points and the relative false points. According to the physics concepts and the Ohm’ Law, an electrical circuit was set up to determine the impedance. This circuit was introduced into three experiments in anesthetized dogs with needles at selected points. In the first two experiments, was applied an alternating tension with 200Hz frequency in the circuit and, in the last experiment, the frequency was increased to 10kHz, the tensions and electrical currents were measured between every pair of points for the all experiments. The impedances were calculated with the values obtained by experiments. The analysis of impedance values indicated that there is a coherent relation between the results and the applied frequencies in circuit, so just at high frequency condition admits the correct measurement of total impedance, therefore the last experiment gave the result which agreed with the theory, that the impedances at acupuncture points are lower than the impedances at false points

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work is to study some of the density estimation tec- niques and to apply to the segmentation of medical images. Medical images are used to help the diagnostic of tumor diseases as well as to plan and deliver treatment. A computer image is an array of values representing colors in some scale. The smallest element of the image to which it is possible to assign a value is called pixel. Segmen- tation is the process of dividing the image in portions through the classi¯cation of each pixel. The simplest way of classi¯cation is by thresholding, given the number of portions and the threshold values. Another method is constructing a histogram of the pixel values and assign a portion to each pike. The threshold is the mean between two pikes. As the histogram does not form a smooth curve it is di±cult to discern between true pikes and random variation. Density estimation methods allow the estimation of a smooth curve. Image data can be considered as mixture of different densities. In this project parametric and nonparametric methods for density estimation will be addressed and some of them are applied to CT image data

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...