977 resultados para work system method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study develops an approach that tries to validate software functionality to work systems needs in SMEs. The formulated approach is constructed by using a SAAS based software i.e., work collaboration service (WCS), and SMEs as the elements of study. Where the WCS’s functionality is qualified to the collaboration needs that exist in operational and project work within SMEs. For this research constructivist approach and case study method is selected because the nature of the current study requires an in depth study of the work collaboration service as well as a detailed study of the work systems within different enterprises. Four different companies are selected in which fourteen interviews are conducted to gather data pertaining. The work systems method and framework are used as a central part of the approach to collect, analyze and interpret the enterprises work systems model and the underlying collaboration needs on operational and project work. On the other hand, the functional model of the WCS and its functionality is determined from functional model analysis, software testing, documentation and meetings with the service vendor. The enterprise work system model and the WCS model are compared to reveal how work progression differs between the two and make visible unaddressed stages of work progression. The WCS functionality is compared to work systems collaboration needs to ascertain if the service will suffice the needs of the project and operational work under study. The unaddressed needs provide opportunities to improve the functionality of the service for better conformity to the needs of enterprise and work. The results revealed that the functional models actually differed in how operational and project work progressed within the stages. WCS shared similar stages of work progression apart from the stages of identification and acceptance, and progress and completion stages were only partially addressed. Conclusion is that the identified unaddressed needs such as, single point of reference, SLA and OLA inclusion etc., should be implemented or improved within the WCS at appropriate stages of work to gain better compliance of the service to the needs of the enterprise an work itself. The developed approach can hence be used to carry out similar analysis for the conformance of pre-built software functionality to work system needs with SMEs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 15 de Março de 2016, Universidade dos Açores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy efficiency and renewable energy use are two main priorities leading to industrial sustainability nowadays according to European Steel Technology Platform (ESTP). Modernization efforts can be done by industries to improve energy consumptions of the production lines. These days, steel making industrial applications are energy and emission intensive. It was estimated that over the past years, energy consumption and corresponding CO2 generation has increased steadily reaching approximately 338.15 parts per million in august 2010 [1]. These kinds of facts and statistics have introduced a lot of room for improvement in energy efficiency for industrial applications through modernization and use of renewable energy sources such as solar Photovoltaic Systems (PV).The purpose of this thesis work is to make a preliminary design and simulation of the solar photovoltaic system which would attempt to cover the energy demand of the initial part of the pickling line hydraulic system at the SSAB steel plant. For this purpose, the energy consumptions of this hydraulic system would be studied and evaluated and a general analysis of the hydraulic and control components performance would be done which would yield a proper set of guidelines contributing towards future energy savings. The results of the energy efficiency analysis showed that the initial part of the pickling line hydraulic system worked with a low efficiency of 3.3%. Results of general analysis showed that hydraulic accumulators of 650 liter size should be used by the initial part pickling line system in combination with a one pump delivery of 100 l/min. Based on this, one PV system can deliver energy to an AC motor-pump set covering 17.6% of total energy and another PV system can supply a DC hydraulic pump substituting 26.7% of the demand. The first system used 290 m2 area of the roof and was sized as 40 kWp, the second used 109 m2 and was sized as 15.2 kWp. It was concluded that the reason for the low efficiency was the oversized design of the system. Incremental modernization efforts could help to improve the hydraulic system energy efficiency and make the design of the solar photovoltaic system realistically possible. Two types of PV systems where analyzed in the thesis work. A method was found calculating the load simulation sequence based on the energy efficiency studies to help in the PV system simulations. Hydraulic accumulators integrated into the pickling line worked as energy storage when being charged by the PV system as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a method of computing PD stabilising gains for rotating systems is presented based on the D-decomposition technique, which requires the sole knowledge of frequency response functions. By applying this method to a rotating system with electromagnetic actuators, it is demonstrated that the stability boundary locus in the plane of feedback gains can be easily plotted, and the most suitable gains can be found to minimise the resonant peak of the system. Experimental results for a Laval rotor show the feasibility of not only controlling lateral shaft vibration and assuring stability, but also helps in predicting the final vibration level achieved by the closed-loop system. These results are obtained based solely on the input-output response information of the system as a whole.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The failure rate of health information systems is high, partially due to fragmented, incomplete, or incorrect identification and description of specific and critical domain requirements. In order to systematically transform the requirements of work into real information system, an explicit conceptual framework is essential to summarize the work requirements and guide system design. Recently, Butler, Zhang, and colleagues proposed a conceptual framework called Work Domain Ontology (WDO) to formally represent users’ work. This WDO approach has been successfully demonstrated in a real world design project on aircraft scheduling. However, as a top level conceptual framework, this WDO has not defined an explicit and well specified schema (WDOS) , and it does not have a generalizable and operationalized procedure that can be easily applied to develop WDO. Moreover, WDO has not been developed for any concrete healthcare domain. These limitations hinder the utility of WDO in real world information system in general and in health information system in particular. Objective: The objective of this research is to formalize the WDOS, operationalize a procedure to develop WDO, and evaluate WDO approach using Self-Nutrition Management (SNM) work domain. Method: Concept analysis was implemented to formalize WDOS. Focus group interview was conducted to capture concepts in SNM work domain. Ontology engineering methods were adopted to model SNM WDO. Part of the concepts under the primary goal “staying healthy” for SNM were selected and transformed into a semi-structured survey to evaluate the acceptance, explicitness, completeness, consistency, experience dependency of SNM WDO. Result: Four concepts, “goal, operation, object and constraint”, were identified and formally modeled in WDOS with definitions and attributes. 72 SNM WDO concepts under primary goal were selected and transformed into semi-structured survey questions. The evaluation indicated that the major concepts of SNM WDO were accepted by 41 overweight subjects. SNM WDO is generally independent of user domain experience but partially dependent on SNM application experience. 23 of 41 paired concepts had significant correlations. Two concepts were identified as ambiguous concepts. 8 extra concepts were recommended towards the completeness of SNM WDO. Conclusion: The preliminary WDOS is ready with an operationalized procedure. SNM WDO has been developed to guide future SNM application design. This research is an essential step towards Work-Centered Design (WCD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this Master’s Thesis a new Distributed Award Protocol (DAP) for robot communication and cooperation is presented. Task assignment (contract awarding) is done dynamically with contracts assigned to robots based upon the best bid received. Instead of having a manager and a contractor it is proposed a fully distributed bidding/awarding mechanism without a distinguished master. The best bidding robots are awarded with contract for execution. The contractors make decisions locally. This brings the following benefits: no communication bottleneck, low computational power requirement, increased robustness. DAP can handle multitasking. Tasks can be injected into system during the execution of already allocated tasks. As tasks have priorities, in the next cycle after taking into account actual bid parameters of all robots, tasks can be re-allocated. The aim is to minimize a global cost function which is a compromise between cost of task execution and cost of resources usage. Information about tasks and bid values is spread among robots with the use of a Round Robin Route, which is a novel solution proposed in this work. This method allows also identifying failed robots. Such failed robot is eliminated from the list of awarded robots and its replacement is found so the task is still executed by a team. If the failure of a robot was temporary (e.g. communication noise) and the robot can recover, it can again participate in the next bidding/awarding process. Using a bidding/awarding mechanism allows robots to dynamically relocate among tasks. This is also contributes to system robustness. DAP was evaluated through multiple experiments done in the multi-robot simulation system. Various scenarios were tested to check the idea of the main algorithm. Different failures of robots (communication failures, partial hardware malfunctions) were simulated and observations were made regarding how DAP recovers from them. Also the DAP flexibility to environment changes was watched. The experiments in the simulated environment confirmed the above features of DAP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: The hospital environment has many occupational health risks that predispose healthcare workers to various kinds of work accidents. OBJECTIVE: This study aims to compare different methods for work accidents investigation and to verify their suitability in hospital environment. METHODS: For this purpose, we selected three types of accidents that were related with needle stick, worker fall and inadequate effort/movement during the mobilization of patients. A total of thirty accidents were analysed with six different work accidents investigation methods. RESULTS: The results showed that organizational factors were the group of causes which had the greatest impact in the three types of work accidents. CONCLUSIONS: The methods selected to be compared in this paper are applicable and appropriate for the work accidents investigation in hospitals. However, the Registration, Research and Analysis of Work Accidents method (RIAAT) showed to be an optimal technique to use in this context.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Information security is concerned with the protection of information, which can be stored, processed or transmitted within critical information systems of the organizations, against loss of confidentiality, integrity or availability. Protection measures to prevent these problems result through the implementation of controls at several dimensions: technical, administrative or physical. A vital objective for military organizations is to ensure superiority in contexts of information warfare and competitive intelligence. Therefore, the problem of information security in military organizations has been a topic of intensive work at both national and transnational levels, and extensive conceptual and standardization work is being produced. A current effort is therefore to develop automated decision support systems to assist military decision makers, at different levels in the command chain, to provide suitable control measures that can effectively deal with potential attacks and, at the same time, prevent, detect and contain vulnerabilities targeted at their information systems. The concept and processes of the Case-Based Reasoning (CBR) methodology outstandingly resembles classical military processes and doctrine, in particular the analysis of “lessons learned” and definition of “modes of action”. Therefore, the present paper addresses the modeling and design of a CBR system with two key objectives: to support an effective response in context of information security for military organizations; to allow for scenario planning and analysis for training and auditing processes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To identify the adherence rate of a statin treatment and possible related factors in female users from the Unified Health System. Method: Seventy-one women were evaluated (64.2 ± 11.0 years) regarding the socio-economic level, comorbidities, current medications, level of physical activity, self-report of muscular pain, adherence to the medical prescription, body composition and biochemical profile. The data were analyzed as frequencies, Chi-Squared test, and Mann Whitney test (p<0.05). Results: 15.5% of women did not adhere to the medical prescription for the statin treatment, whose had less comorbidities (p=0.01), consumed less quantities of medications (p=0.00), and tended to be younger (p=0.06). Those patients also presented higher values of lipid profile (CT: p=0.01; LDL-c: p=0.02). Musculoskeletal complains were not associated to the adherence rate to the medication. Conclusion: The associated factors to adherence of dyslipidemic women to statin medical prescription were age, quantity of comorbidities and quantity of current medication.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: Testing the psychometric properties of the Portuguese version of the Practice Environment Scale of the Nursing Work Index. Method: A descriptive, analytical and cross-sectional study, for the cross-cultural adaptation and validation of the psychometric properties of the scale. The study participants were 236 nurses from two hospitals in the regions of Lisbon and Vale do Tejo. Results: The 0.92 Cronbach’s alpha was obtained for overall reliability and support of a five-dimension structure. Conclusion: The excellent quality of adjustment of analysis confirms the validity of the adapted version to hospital care settings, although there was no total coincidence of items in the five dimensions


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The accumulation of aqueous pollutants is becoming a global problem. The search for suitable methods and/or combinations of water treatment processes is a task that can slow down and stop the process of water pollution. In this work, the method of wet oxidation was considered as an appropriate technique for the elimination of the impurities present in paper mill process waters. It has been shown that, when combined with traditional wastewater treatment processes, wet oxidation offers many advantages. The combination of coagulation and wet oxidation offers a new opportunity for the improvement of the quality of wastewater designated for discharge or recycling. First of all, the utilization of coagulated sludge via wet oxidation provides a conditioning process for the sludge, i.e. dewatering, which is rather difficult to carry out with untreated waste. Secondly, Fe2(SO4)3, which is employed earlier as a coagulant, transforms the conventional wet oxidation process into a catalytic one. The use of coagulation as the post-treatment for wet oxidation can offer the possibility of the brown hue that usually accompanies the partial oxidation to be reduced. As a result, the supernatant is less colored and also contains a rather low amount of Fe ions to beconsidered for recycling inside mills. The thickened part that consists of metal ions is then recycled back to the wet oxidation system. It was also observed that wet oxidation is favorable for the degradation of pitch substances (LWEs) and lignin that are present in the process waters of paper mills. Rather low operating temperatures are needed for wet oxidation in order to destruct LWEs. The oxidation in the alkaline media provides not only the faster elimination of pitch and lignin but also significantly improves the biodegradable characteristics of wastewater that contains lignin and pitch substances. During the course of the kinetic studies, a model, which can predict the enhancements of the biodegradability of wastewater, was elaborated. The model includes lumped concentrations suchas the chemical oxygen demand and biochemical oxygen demand and reflects a generalized reaction network of oxidative transformations. Later developments incorporated a new lump, the immediately available biochemical oxygen demand, which increased the fidelity of the predictions made by the model. Since changes in biodegradability occur simultaneously with the destruction of LWEs, an attempt was made to combine these two facts for modeling purposes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background New recommendations for rabies postexposure prophylaxis (rPEP) were published by the Centers for Disease Control and Prevention and the World Health Organization in 2010. In view of these new recommendations, the adequacy of rPEP among patients consulting the travel clinic of the University Hospital of Lausanne has been investigated and 6,8% of patients have been identified as non-responders with the new rPEP regimen. In this study we have selected the non-responders for a complete immunologic work up. Method Clinical and paraclinical immunologic investigations have been done to the non- responders patients. Those investigations have been conducted to look for an increased susceptibility to infections and an immunodeficiency. The investigations included a clinical evaluation, a full blood count, measurement of the immunoglobulin levels, a numeration of the subpopulations of the lymphocytes, a HIV test and an evaluation of the humoral response to tetanus, pneumococcal, and hepatitis B vaccinations. A lymphocyte proliferation assay with rabies antigen was performed to assess the cellular immune response. Results 9 subjects with rabies antibody titers ≤0,5 IU/ml after an rPEP with 4 doses were included in this study (=non-responders). 8/9 of these non-responders had an unremarkable medical history. 9/9 of them had normal paraclinical tests that did not suggest an immunodeficiency. The results of the lymphocyte proliferation assay with rabies antigen showed a significant correlation between the level of the humoral and cellular response. Conclusion These results suggest that a 4 dose intramuscular rPEP elicits in some patients a relatively poor humoral and cellular response, even in the absence of any immunosuppression. A serology on day 21 of the rPEP seems therefore useful to identify the patients who don't respond appropriately. Those non-responders should receive additional doses until they reach an antibody titer above 0.5 IU/ml.