434 resultados para stripping chronopotentiometry
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This paper proposes a simple methodology for mercury quantification in natural water by stripping chronopotentiometry at constant current, using gold (film) electrodes constructed from recordable CDs in stationary cell. The proposed method allows the direct measurement of labile mercury in natural waters. To quantify total mercury, a robust and low cost UV irradiation system was developed for the degradation of organic constituents of water. The proposed system presents such advantages as excellent sensitivity, low cost, versatility, and smaller dimensions (portability for on-field applications) when compared with other techniques (ICP, GFAAS, fluorimetry) traditionally utilized for mercury quantification. A large linear region of responses was observed, situated over the range 0.02 - 200 μ g L-1. Various experimental parameters were optimized and the system allowed quantifications in natural samples, with detection limit of 8 ng L-1 and excellent reproducibility (RSD of 1.4% for 48 repetitive measurements using a 10 μ g L-1 mercury solution). Different metal ions were evaluated, including copper, as possible interferences on stripping mercury signals. Applications of the new method were demonstrated for the analysis of certified and groundwater samples spiked with a known amount of mercury and for the quantification of methylmercury in synthetic oceanic water, originally utilized for fishes contamination experiment.
Resumo:
Au cours de la dernière décennie, les nanoparticules ont connu un essor sans précédent dans plusieurs domaines. On peut retrouver ces nanoparticules dans des secteurs aussi variés tels que la médecine, l’électronique, les écrans solaires, les cosmétiques et les plastiques, pour ne nommer que ceux-là. Cette utilisation massive a eu un effet pervers sur l’environnement, sachant qu’une grande partie de ces produits se sont retrouvés inévitablement dans les milieux naturels. Plusieurs études révèlent qu’autant la présence des nanoparticules que leurs produits de dissolution sont à prendre en considération lorsque des travaux toxicologiques ou le devenir de ces matériaux sont étudiés. Il est désormais clair que les propriétés de surface de ces nanoparticules jouent un rôle central sur leur comportement dans les solutions aqueuses; que ce soit les interactions avec des organismes ou entre les particules elles-mêmes. Afin d’évaluer le devenir de nZnO, une étude sur la dissolution ainsi que la bioaccumulation a été réalisée avec l’algue modèle Chlamydomonas reinhardtii en présence de nanoparticules ayant différents enrobages. Les nanoparticules d’oxyde de zinc suivantes ont été étudiées : (i) nZnO sans enrobage (nZnO); (ii) nZnO avec enrobage d’acide polyacrylique (nZnO-PAA) et (iii) nZnO avec enrobage d’hexamétaphosphate de sodium (nZnO-HMP). La dissolution était mesurée à l’aide de trois techniques : ultrafiltration par centrifugation (CU); technique potentiométrique (scanned stripping chronopotentiometry, SSCP) et spectrométrie de masse – plasma à couplage inductif couplé à une résine échangeuse d’ions (resin-based inductively coupled plasma-mass spectrometry, resin-based ICP-MS). Les résultats obtenus démontrent une grande tendance à la dissolution pour le nZnO (presque totale) tandis que pour le nZnO-PAA et le nZnO-HMP, la dissolution est dépendante de la nature de l’enrobage le composant. Pour la bioaccumulation sur l’algue testée, les données montrent une grande dépendance au zinc libre issu de la dissolution pour nZnO et nZnO-PAA. À l’inverse, le nZnO-HMP démontre une bioaccumulation plus élevée par comparaison aux mêmes concentrations d’expositions du zinc libre, expliquée par la stimulation de l’internalisation du zinc provoqué par la présence de phosphate constituant l’enrobage de nZnO-HMP.
Resumo:
Carbon fiber ultramicroelectrodes are shown to be suitable for adsorptive stripping potentiometric measurements of trace DNA and RNA. The origin of the carbon fiber has a profound effect upon its suitability for trace analysis of nucleic acids, with the 'Aesar' materials performing most favorably. The resulting ultramicroelectrodes offer effective adsorptive accumulation of DNA and RNA from unstirred microliter-volume solutions, and are shown to be useful in adsorptive stripping transfer experiments. The influence of the surface pretreatment and accumulation conditions is described, along with the analytical-performance characteristics. The detection limits are 6, 15 and 40 mu g/l tRNA, ssDNA and dsDNA, respectively (5 min accumulation). (C) 1998 Elsevier B.V. S.A.
Resumo:
A highly sensitive adsorptive stripping procedure for trace measurement of the anticancer drug tamoxifen is described. The method is based on controlled adsorptive accumulation of the drug at an electrochemically treated glassy carbon electrode, followed by chronopotentiometric measurement of the surface species. The chronopotentiometric operation effectively addresses the large background contribution inherent to the glassy carbon electrode to yield a detection limit of 4 x 10(-10) M after 4 min preconcentration. The adsorptive stripping response is evaluated with respect to electrode type and conditioning, accumulation potential and lime, stripping current, pH, drug concentration, potential interferences, and other variables. Applicability to urine samples is illustrated. (C) 1997 Elsevier B.V. B.V.
Resumo:
The flux of a compound across a membrane from any formulation, whether it contains penetration enhancers or not, is limited by its saturated solubility in the vehicle. Under such conditions the concentration of the permeant in the outer layers of the stratum corneum is also saturated. Consequently, when the permeation of a drug from a supersaturated solution leads to enhanced penetration, the concentration of the drug in the outer layers of the membrane is also supersaturated. Therefore, the stratum corneum may possess antinucleant properties which inhibit or retard the crystallisation process. In this study, the enhanced in vitro permeation of supersaturated solutions of piroxicam across human skin in diffusion cells was demonstrated. The amount of permeant in the stratum corneum was determined using a tape stripping technique. Supersaturated solutions up to four degrees of saturation were investigated which produced a linear relationship between the degree of saturation and the amount of piroxicam in the stratum corneum (R-2 = 0.970). Furthermore, the amount of piroxicam in the viable layers of the skin also increased with increasing degree of saturation. An analysis of the results suggested that enhanced penetration across human skin from supersaturated solutions of piroxicam may occur as a result of the antinucleating ability of the intercellular lipids of the stratum corneum. (C) 1997 Elsevier Science B.V.
Resumo:
A methodology for the determination of the pesticide chlorfenvinphos by microwave-assisted solvent extraction and square-wave cathodic stripping voltammetry at a mercury film ultramicroelectrode in soil samples is proposed. Optimization of microwave solvent extraction performed with two soils, selected for having significantly different properties, indicated that the optimum solvent for extracting chlorfenvinphos is hexane-acetone (1:1, v/v). The voltammetric procedure is based on controlled adsorptive accumulation of the insecticide at the potential of -0.60 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 6.2). The detection limit obtained for a 10 s collection time was 3.0 x 10-8 mol l-1. The validity of the developed methodology was assessed by recovery experiments at the 0.100 µg g-1 level. The average recoveries and standard deviations for the global procedure reached byMASE-square-wave voltammetry were 90.2±2.8% and 92.1±3.4% for type I (soil rich in organic matter) and type II (sandy soil) samples, respectively. These results are in accordance to the expected values which show that the method has a good accuracy.
Resumo:
An adsorptive stripping voltammetric procedure for the determination of the antidepressant venlafaxine in urine using a mercury film microelectrode wasdeveloped. The method is based on controlled adsorptive accumulation of the drug at the potential of 1.00V (vs. Ag/AgCl) in the presence of 1.25 x10 -2 molL- 1 borate buffer (pH 8.7). Urine samples were analyzed directly after performing a ten-fold dilution with the supporting electrolyte but without other pretreatment. The limit of detection obtained for a 30 s collection time was 0.693x 10- 6 mol L -1. Recovery experimentsgave good results at the 10 -6 mol L- 1 level (bias less 5% were obtained).
Resumo:
Microwave-assisted solvent extraction was combined with anodic adsorptive stripping voltammetry at a gold microelectrode to extract and quantify the herbicide atrazine in spiked soil samples. A systematic study of the experimental parameters affecting the stripping response was carried out by square-wave voltammetry. The voltammetric procedure is based on controlled adsorptive accumulation of atrazine at the potential of 0.35V (versus Ag/AgCl) in the presence of Britton–Robinson buffer pH (2.0). The limit of detection obtained for a 30 sec collection time was 4.3x10-7 mol L-1. Recovery experiments, at the 1µgg-1 level of spiking, gave good results for the global procedure, and the values found were comparable to those obtained by HPLC.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.
Resumo:
An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.
Resumo:
This work deals with the numerical simulation of air stripping process for the pre-treatment of groundwater used in human consumption. The model established in steady state presents an exponential solution that is used, together with the Tau Method, to get a spectral approach of the solution of the system of partial differential equations associated to the model in transient state.
Resumo:
Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for the column design for any particular type of packing and contaminant avoiding the necessity of a pre-defined diameter used in the classical approach. It also renders unnecessary the employment of the graphical Eckert generalized correlation for pressure drop estimates. The hydraulic features are previously chosen as a project criterion and only afterwards the mass transfer phenomena are incorporated, in opposition to conventional approach. The design procedure was translated into a convenient algorithm using C++ as programming language. A column was built in order to test the models used either in the design or in the simulation of the column performance. The experiments were fulfilled using a solution of chloroform in distilled water. Another model was built to simulate the operational performance of the column, both in steady state and in transient conditions. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting system of ODE can be solved, allowing for the calculation of the concentration profile in both phases inside the column. In transient state the system of PDE was numerically solved by finite differences, after a previous linearization.