842 resultados para smaltimento reflui on-site sanitation madagascar


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nearly 50% of India's population depends on variants of pit-toilet systems for human waste disposal. Nitrate contamination of groundwater by pit-toilet leachate is a major environmental concern in the country as it sources a major proportion (50-80%) of potable water from aquifers. Therefore, minimizing nitrate contamination of groundwater due to leachate infiltration from pit-toilet systems is essential. Batch and column experiments demonstrated the capability of bentonite-enhanced sand (BES) specimens to reduce nitrate concentrations in synthetic solutions (initial NO3-N concentration = 22.7 mg/L, C/N = 3) by about 85-90% in 10 to 24 hour by a heterotrophic denitrification process. Based on the laboratory results, it is recommended that use of a BES-permeable reactive barrier layer at the base of pit-toilets will facilitate heterotrophic denitrification and mitigate nitrate contamination of the underlying aquifer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scopo di questo lavoro di tesi è quello di sperimentare “sul campo’’ la validità e l'efficacia di tecniche SBR per il trattamento delle acque domestiche per case sparse e nuclei isolati. Tuttavia quella SBR, pur essendo una tecnica impiantistica, può soddisfare queste esigenze. Grazie alla presenza di un adeguato volume d'accumulo ed al funzionamento ciclico dell'impianto sono annullati tutti i problemi determinati, nei normali impianti in continuo, dalla discontinuità dell'afflusso di reflui (picchi di portata). L'impianto è studiato per ridurre la necessità di manutenzione al minimo: tutte le apparecchiature tecniche sono collocate in un armadio esterno all'impianto ed in vasca ci sono solo le tubazioni. Ciò esclude ogni presenza interna al serbatoio di apparecchiature elettriche e di parti in movimento soggette a usura. Il vantaggio è evidente nella semplificazione delle operazioni di gestione/controllo/manutenzione dell’impianto che non richiedono, di norma, lo svuotamento della cisterna e consentono operazioni più agevoli e sicure.Tutti i movimenti di processo sono supportati da tre sistemi Air Lift azionati da un unico compressore che provvede anche all'immissione dell'ossigeno attraverso l'aeratore tubolare a membrana nella vasca SBR. Il compressore si caratterizza per lunga vita operativa e assoluta silenziosità di funzionamento. Per verificare l’efficacia del processo depurativo indotto dall’impianto SBR installato dalla GreenSolar abbiamo fatto dei prelievi sul liquame in entrata alla camera SBR e su quello in uscita da essa. I campioni così prelevati sono stati analizzati da un laboratorio autorizzato.I valori limite imposti dal DGR n. 1053 sono ampiamente rispettati, tuttavia i risultati ottenuti non sono soddisfacenti relativamente alle potenzialità dell'impianto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Office building retrofit projects are increasingly more intensified as existing buildings are aging. At the same time, building owners and occupants are looking for environmentally sustainable products. These retrofit projects usually take place in center business district (CBDs) with on-site waste becoming one of the critical issues. Small and Medium Enterprises (SMEs) carry out most of the work in retrofit projects as subcontractors. Despite their large involvement, they often do not have adequate resources to deal with the specific technical challenges and project risks related to waste. Few research has been done on their performance of waste management operations. This paper identifies characteristics of on-site waste in office building retrofit projects. It examines the specific requirements for contractors to manage waste in the projects before exploring the existing performance of SMEs. By comparing requirements for SMEs and their potential areas for improvement, a framework is established for performance promotion of SMEs in on-site waste management of office building retrofit projects. The paper will raise the consciousness and commitment of SMEs as sub-contractors to waste management. It also explores ways of supporting SMEs for experience accumulation, performance promotion and project culture establishment towards effective and efficient on-site waste management in the growing sector of office building retrofit and upgrade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background On-site wastewater treatment system (OWTS) siting, design and management has traditionally been based on site specific conditions with little regard to the surrounding environment or the cumulative effect of other systems in the environment. The general approach has been to apply the same framework of standards and regulations to all sites equally, regardless of the sensitivity, or lack thereof, to the receiving environment. Consequently, this has led to the continuing poor performance and failure of on-site systems, resulting in environmental and public health consequences. As a result, there is increasing realisation that more scientifically robust evaluations in regard to site assessment and the underlying ground conditions are needed. Risk-based approaches to on-site system siting, design and management are considered the most appropriate means of improvement to the current standards and codes for on-site wastewater treatment systems. The Project Research in relation to this project was undertaken within the Gold Coast City Council region, the major focus being the semi-urban, rural residential and hinterland areas of the city that are not serviced by centralised treatment systems. The Gold Coast has over 15,000 on-site systems in use, with approximately 66% being common septic tank-subsurface dispersal systems. A recent study evaluating the performance of these systems within the Gold Coast area showed approximately 90% were not meeting the specified guidelines for effluent treatment and dispersal. The main focus of this research was to incorporate strong scientific knowledge into an integrated risk assessment process to allow suitable management practices to be set in place to mitigate the inherent risks. To achieve this, research was undertaken focusing on three main aspects involved with the performance and management of OWTS. Firstly, an investigation into the suitability of soil for providing appropriate effluent renovation was conducted. This involved detailed soil investigations, laboratory analysis and the use of multivariate statistical methods for analysing soil information. The outcomes of these investigations were developed into a framework for assessing soil suitability for effluent renovation. This formed the basis for the assessment of OWTS siting and design risks employed in the developed risk framework. Secondly, an assessment of the environmental and public health risks was performed specifically related the release of contaminants from OWTS. This involved detailed groundwater and surface water sampling and analysis to assess the current and potential risks of contamination throughout the Gold Coast region. Additionally, the assessment of public health risk incorporated the use of bacterial source tracking methods to identify the different sources of fecal contamination within monitored regions. Antibiotic resistance pattern analysis was utilised to determine the extent of human faecal contamination, with the outcomes utilised for providing a more indicative public health assessment. Finally, the outcomes of both the soil suitability assessment and ground and surface water monitoring was utilised for the development of the integrated risk framework. The research outcomes achieved through this project enabled the primary research aims and objects to be accomplished. This in turn would enable Gold Coast City Council to provide more appropriate assessment and management guidelines based on robust scientific knowledge which will ultimately ensure that the potential environmental and public health impacts resulting from on-site wastewater treatment is minimised. As part of the implementation of suitable management strategies, a critical point monitoring program (CPM) was formulated. This entailed the identification of the key critical parameters that contribute to the characterised risks at monitored locations within the study area. The CPM will allow more direct procedures to be implemented, targeting the specific hazards at sensitive areas throughout Gold Coast region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The implementation of the National Professional Standards for Teachers (Australian Institute for Teaching and School Leadership (AITSL), 2011) will require all teachers to undertake 30 hours per year of professional development (PD) to maintain thei registration. However, defining what constitutes effective PD s complex. This article discusses an approach used by Narangba Valley State High School (SHS) in Queensland which involves effective on-site PD, resulting in improved student outcomes. In addition to the school-administered growth and learning (GAL) plans for each teacher, the school worked collaboratively with an external person (university lecturer) and implemented an effective, sustainable, whole-school approach to PD which was ongoing, on time, on task, on the mark, and on-the-spot (Jetnikoff & Smeed, 2012). The article unpacks an interview with Ross Mackay, the Narangba Valley SHS executive-principal and one of the authors of this paper, and provides practical advice for other school leaders wishing to implement a similar approach to PD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents research findings and design strategies that illustrate how digital technology can be applied as a tool for hybrid placemaking in ways that would not be possible in purely digital or physical space. Digital technology has revolutionised the way people learn and gather new information. This trend has challenged the role of the library as a physical place, as well as the interplay of digital and physical aspects of the library. The paper provides an overview of how the penetration of digital technology into everyday life has affected the library as a place, both as designed by place makers, and, as perceived by library users. It then identifies a gap in current library research about the use of digital technology as a tool for placemaking, and reports results from a study of Gelatine – a custom built user check-in system that displays real-time user information on a set of public screens. Gelatine and its evaluation at The Edge, at State Library of Queensland illustrates how combining affordances of social, spatial and digital space can improve the connected learning experience among on-site visitors. Future design strategies involving gamifying the user experience in libraries are described based on Gelatine’s infrastructure. The presented design ideas and concepts are relevant for managers and designers of libraries as well as other informal, social learning environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To determine: (1) the accuracy of cytology scientists at assessing specimen adequacy by rapid on-site evaluation (ROSE) at fine needle aspiration (FNA) cytology collections; and (2) whether thyroid FNA with ROSE has lower inadequacy rates than non-attended FNAs. Methods The ROSE of adequacy for 3032 specimens from 17 anatomical sites collected over a 20-month period was compared with the final report assessment of adequacy. ROSE was performed by 19 cytology scientists. The report profile for 1545 thyroid nodules with ROSE was compared with that for 1536 consecutive non-ROSE thyroid FNAs reported by the same cytopathologists during the study period. Results ROSE was adequate in 75% (2276/3032), inadequate in 12% (366/3032) and in 13% (390/3032) no opinion was rendered. Of the 2276 cases assessed as adequate by ROSE, 2268 (99.6%) were finally reported as adequate for assessment; eight specimens had adequacy downgraded on the final report. Fifty eight per cent of cases with a ROSE assessment of inadequate were reported as adequate (212/366), whereas 93% (363/390) with no opinion rendered were reported as adequate. The overall final report adequacy rate for the 3032 specimens was 94% (2843/3032). Confirmation of a ROSE of adequacy at reporting was uniformly high amongst the 19 scientists, ranging from 98% to 100%. The inadequacy rate for thyroid FNAs with ROSE (6%) was significantly (P < 0.0001) lower than for non-ROSE thyroid FNAs (17%). A significantly (P = 0.02) higher proportion of adequate ROSE thyroid specimens was reported with abnormalities, compared with non-ROSE thyroid collections. Conclusions Cytology scientists are highly accurate at determining specimen adequacy at ROSE for a wide range of body sites. ROSE of thyroid FNAs can significantly reduce inadequate reports.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among several others, the on-site inspection process is mainly concerned with finding the right design and specifications information needed to inspect each newly constructed segment or element. While inspecting steel erection, for example, inspectors need to locate the right drawings for each member and the corresponding specifications sections that describe the allowable deviations in placement among others. These information seeking tasks are highly monotonous, time consuming and often erroneous, due to the high similarity of drawings and constructed elements and the abundance of information involved which can confuse the inspector. To address this problem, this paper presents the first steps of research that is investigating the requirements of an automated computer vision-based approach to automatically identify “as-built” information and use it to retrieve “as-designed” project information for field construction, inspection, and maintenance tasks. Under this approach, a visual pattern recognition model was developed that aims to allow automatic identification of construction entities and materials visible in the camera’s field of view at a given time and location, and automatic retrieval of relevant design and specifications information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vision trackers have been proposed as a promising alternative for tracking at large-scale, congested construction sites. They provide the location of a large number of entities in a camera view across frames. However, vision trackers provide only two-dimensional (2D) pixel coordinates, which are not adequate for construction applications. This paper proposes and validates a method that overcomes this limitation by employing stereo cameras and converting 2D pixel coordinates to three-dimensional (3D) metric coordinates. The proposed method consists of four steps: camera calibration, camera pose estimation, 2D tracking, and triangulation. Given that the method employs fixed, calibrated stereo cameras with a long baseline, appropriate algorithms are selected for each step. Once the first two steps reveal camera system parameters, the third step determines 2D pixel coordinates of entities in subsequent frames. The 2D coordinates are triangulated on the basis of the camera system parameters to obtain 3D coordinates. The methodology presented in this paper has been implemented and tested with data collected from a construction site. The results demonstrate the suitability of this method for on-site tracking purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among several others, the on-site inspection process is mainly concerned with finding the right design and specifications information needed to inspect each newly constructed segment or element. While inspecting steel erection, for example, inspectors need to locate the right drawings for each member and the corresponding specifications sections that describe the allowable deviations in placement among others. These information seeking tasks are highly monotonous, time consuming and often erroneous, due to the high similarity of drawings and constructed elements and the abundance of information involved which can confuse the inspector. To address this problem, this paper presents the first steps of research that is investigating the requirements of an automated computer vision-based approach to automatically identify “as-built” information and use it to retrieve “as-designed” project information for field construction, inspection, and maintenance tasks. Under this approach, a visual pattern recognition model was developed that aims to allow automatic identification of construction entities and materials visible in the camera’s field of view at a given time and location, and automatic retrieval of relevant design and specifications information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ingress of chlorides into concrete is predominantly by the mechanism of diffusion and the resistance of concrete to the transport of chlorides is generally represented by its coefficient of diffusion. The determination of this coefficient normally requires long test duration (many months). Therefore, rapid test methods based on the electrical migration of ions have widely been used. The current procedure of chloride ion migration tests involves placing a concrete disc between an ion source solution and a neutral solution and accelerating the transport of ions from the source solution to the neutral solution by the application of a potential difference across the concrete disc. This means that, in order to determine the chloride transport resistance of concrete cover, cores should be extracted from the structure and tested in laboratories. In an attempt to facilitate testing of the concrete cover on site, an in situ ion migration test (hereafter referred to as PERMIT ion migration test for the unique identification of the new test) was developed. The PERMIT ion migration test was validated in the lab by carrying out a comparative investigation and correlating the results with the migration coefficient from the one-dimensional chloride migration test, the effective diffusion coefficient from the normal diffusion test and the apparent diffusion coefficient determined from chloride profiles. A range of concrete mixes made with ordinary Portland cement was used for this purpose. In addition, the effects of preferential flow of ions close to the concrete surface and the proximity of reinforcement within the test area on the in situ migration coefficients were investigated. It was observed that the in situ migration index, found in one working day, correlated well with the chloride diffusion coefficients from other tests. The quality of the surface layer of the cover concrete and the location of the reinforcement within the test area were found to affect the flow of ions through the concrete during the test. Based on the data, a procedure to carry out the PERMIT ion migration test was standardised.