990 resultados para simultaneous multicomponent analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL(-1) (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT. PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the reaction between the analytes and methylthymol blue at pH 11. The spectral information was used as the X-block, and the Ca(II) and Mg(II) concentrations obtained by a reference technique (ICP-AES) were used as the Y-block. Two series of analyses were performed, with a month's difference between them. The first series was used as the calibration set and the second one as the validation set. Multivariate statistical process control (MSPC) techniques, based on statistics from principal component models, were used to study the features and evolution with time of the spectral signals. Signal standardization was used to correct the deviations between series. Method validation was performed by comparing the predictions of the PLS model with the reference Ca(II) and Mg(II) concentrations determined by ICP-AES using the joint interval test for the slope and intercept of the regression line with errors in both axes. (C) 1998 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Background Sequential physicochemical alterations in blood and urine in the course of acute kidney injury (AKI) development have not been previously described. We aimed to describe these alterations in parallel to traditional renal and acid–base parameters. Methods One hundred and sixty eight consecutive critically ill patients with no previous kidney disease, who had an indwelling urinary catheter at ICU admission and who remained with the catheter for at least two days without dialysis were included. A sample of blood and spot urine were collected simultaneously, once daily, until catheter removal or dialysis requirement. Traditional acid–base and renal parameters were sequentially evaluated in parallel to blood and urinary physicochemical parameters. Patients were classified during this period as having or not AKI and, for patients with AKI, duration (transient or persistent) and severity (creatinine-based AKIN stage) were evaluated. Results One hundred and thirteen patients (67.3%) had AKI: 92 at ICU admission and 21 during the observation period. AKI development was characterized in blood by increased values of phosphate and unmeasured anions (SIG), decreased albumin, and in urine by decreased values of sodium (NaU), chloride (ClU) as well as high urinary strong ion difference (SIDu). These alterations began to occur before AKI diagnosis, and they reverted in transient AKI but remained in persistent AKI. NaU, ClU and albumin decreased, and phosphate, SIG and SIDu increased with AKI severity progression. NaU and ClU values increased again when AKIN stage 3 was reached. Conclusions Simultaneous physicochemical analysis of blood and urine revealed standardized alterations that characterize AKI development in critically ill patients. These alterations paralleled AKI duration and severity. Future studies should consider including sequential evaluation of urine biochemistry as part of the armamentarium for AKI diagnosis and management.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A MATLAB-based computer code has been developed for the simultaneous wavelet analysis and filtering of multichannel seismic data. The considered time–frequency transforms include the continuous wavelet transform, the discrete wavelet transform and the discrete wavelet packet transform. The developed approaches provide a fast and precise time–frequency examination of the seismograms at different frequency bands. Moreover, filtering methods for noise, transients or even baseline removal, are implemented. The primary motivation is to support seismologists with a user-friendly and fast program for the wavelet analysis, providing practical and understandable results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A MATLAB-based computer code has been developed for the simultaneous wavelet analysis and filtering of several environmental time series, particularly focused on the analyses of cave monitoring data. The continuous wavelet transform, the discrete wavelet transform and the discrete wavelet packet transform have been implemented to provide a fast and precise time–period examination of the time series at different period bands. Moreover, statistic methods to examine the relation between two signals have been included. Finally, the entropy of curves and splines based methods have also been developed for segmenting and modeling the analyzed time series. All these methods together provide a user-friendly and fast program for the environmental signal analysis, with useful, practical and understandable results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for simultaneous determination of Cr, Fe, Co, Ni, Cu, Zn, As e Pb in liquid chemical waste using Energy Dispersive X-Ray Fluorescence (EDXRF) technique was evaluated. A small sample amount (200 mu L) was dried on a 6.35 mu m thickness Mylar film at 60 degrees C and the analyses were carried out using an EDXRF spectrometer operated with an X-ray Mo tube (Zr filter) at 30 kV/20 mA. The acquisition time was 300 s and the Ga element was utilized as internal standard at 25 mg/L for quantitative analysis. The method trueness was assessed by spiking and the detection limit for those elements ranged from 0.39 to 1.7 mg/L. This method is notable because it assists the choice of the more appropriated waste treatment procedure, in which inter elemental interference is a matter of importance. In addition, this inexpensive method allows a non-destructive determination of the elements from (19)K to (92)U simultaneously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We investigated whether neuron-specific enolase (NSE) in serum or cerebrospinal fluid (CSF) reflects subtle or manifest brain injury in children undergoing cardiac surgery using cardiopulmonary bypass (CPB). NSE was measured in serum (s-NSE) before, and up to, 102 h after surgery in 27 children undergoing cardiac surgery with CPB. In 11 children, CSF-NSE was also measured 48 or 66 h post-surgery. As erythrocytes contain NSE, hemoglobin concentration in the samples was determined spectrophotometrically at 550 nm (cut-off limit: absorbance 0.4 = 560 mg/l) in 14 children and in a further 13 children by spectroscopic multicomponent analysis (cut-off limit 5 micromol/l = 80 mg/l). One hundred and one of 214 post-operative serum samples (47%) had to be discarded because of hemolysis (18% spectrophotometrically at 550 nm and 88% with spectroscopic multicomponent analysis). On the first and second post-operative day, the median s-NSE values were significantly higher when compared with samples taken after 54 h or longer (P = 0.008 and P = 0.002). All CSF-NSE levels were within the normal range and below the s-NSE measured in the same patient. Although in our study elevated s-NSE seems to indicate brain injury in CPB-surgery, the low concentration of NSE in the post-operative CSF of 11 children puts the neuronal origin of s-NSE in question. NSE from other non-neuronal tissues probably contributes to the elevated s-NSE. Additionally, normal post-operative CSF-NSE values in two children with post-operative neurological sequelae might question the predictive value of CSF-NSE with regard to brain injury.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Pretreatment measurements of systemic inflammatory response, including the Glasgow prognostic score (GPS), the neutrophil-to-lymphocyte ratio (NLR), the monocyte-to-lymphocyte ratio (MLR), the platelet-to-lymphocyte ratio (PLR) and the prognostic nutritional index (PNI) have been recognized as prognostic factors in clear cell renal cell carcinoma (CCRCC), but there is at present no study that compared these markers. METHODS: We evaluated the pretreatment GPS, NLR, MLR, PLR and PNI in 430 patients, who underwent surgery for clinically localized CCRCC (pT1-3N0M0). Associations with disease-free survival were assessed with Cox models. Discrimination was measured with the C-index, and a decision curve analysis was used to evaluate the clinical net benefit. RESULTS: On multivariable analyses, all measures of systemic inflammatory response were significant prognostic factors. The increase in discrimination compared with the stage, size, grade and necrosis (SSIGN) score alone was 5.8 % for the GPS, 1.1-1.4 % for the NLR, 2.9-3.4 % for the MLR, 2.0-3.3 % for the PLR and 1.4-3.0 % for the PNI. On the simultaneous multivariable analysis of all candidate measures, the final multivariable model contained the SSIGN score (HR 1.40, P < 0.001), the GPS (HR 2.32, P < 0.001) and the MLR (HR 5.78, P = 0.003) as significant variables. Adding both the GPS and the MLR increased the discrimination of the SSIGN score by 6.2 % and improved the clinical net benefit. CONCLUSIONS: In patients with clinically localized CCRCC, the GPS and the MLR appear to be the most relevant prognostic measures of systemic inflammatory response. They may be used as an adjunct for patient counseling, tailoring management and clinical trial design.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The made research is focused on possibility of application of non ferrous metals in boiler pressure parts as a substitute of currently used ferrous-base alloys. The main issue was to define resistive ability of some perspective non ferrous metals to chlorine induced corrosion. Experimental study was performed using simultaneous thermal analysis (STA) in the temperature range of 400-700 °C. The chloride induced corrosion was simulated by mixtures of metal samples with potassium chloride treated by synthetic air. The advantage of synergetic effect of non ferrous alloys compare to single metals is shown due to the obtained data from conducted thermal balance tests.