1000 resultados para polycarbonate membrane


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Template electrodeposition has been used to prepare a wide range of nanostructures but has generally been restricted to aqueous electrolytes. We report the deposition of silver nanowires in a commercial nuclear track-etched polycarbonate template from the nonaqueous ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][PF6]) using silver electrochemically dissolved from the anode. Transmission electron microscopy (TEM) shows that the nanowires have a very high aspect ratio with an average diameter of 80 nm and length of 5 mu m. Ionic liquid electrolytes should greatly extend the range of metals that can be electrodeposited as nanowires using templates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Corneal tissue engineering has improved dramatically over recent years. It is now possible to apply these technological advancements to the development of superior in vitro ocular surface models to reduce animal testing. We aim to show the effect different substrates can have on the viability of expanded corneal epithelial cells and that those which more accurately mimic the stromal surface provide the most protection against toxic assault. Compressed collagen gel as a substrate for the expansion of a human epithelial cell line was compared against two well-known substrates for modeling the ocular surface (polycarbonate membrane and conventional collagen gel). Cells were expanded over 10 days at which point cell stratification, cell number and expression of junctional proteins were assessed by electron microscopy, immunohistochemistry and RT-PCR. The effect of increasing concentrations of sodium lauryl sulphate on epithelial cell viability was quantified by MTT assay. Results showed improvement in terms of stratification, cell number and tight junction expression in human epithelial cells expanded upon either the polycarbonate membrane or compressed collagen gel when compared to a the use of a conventional collagen gel. However, cell viability was significantly higher in cells expanded upon the compressed collagen gel. We conclude that the more naturalistic composition and mechanical properties of compressed collagen gels produces a more robust corneal model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Liposomes of soya phosphatidylcholine, cholesterol, and stearylamine (molar ratio 6/3/1) and 0.1% alpha-tocopherol were prepared by the extrusion of multilamellar vesicles through 0.2-mu m polycarbonate membrane. Liposomes were characterized by electron transmission microscopy, and the mean structure diameter was 278 nm. The encapsulation efficiency obtained was 12.73%. The topical anti-inflammatory effect was evaluated in vivo by the cotton pellet granuloma method. We analyzed free piroxicam at 4 mg/kg, piroxicam encapsulated in liposomes added to 1.5% hydroxyethylcellulose (HEC) gel at 1.6 mg/kg, and piroxicam encapsulated in liposomes added to HEC gel at 4 mg/kg; the inhibition of inflammation obtained was 21.1%, 32.8%, and 47.4%, respectively. These results showed that the encapsulation of piroxicam produced an increase of topical anti-inflammatory effect, suggesting that the inhibition of inflammation can be obtained with lower drug concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Different procedures for obtaining a needle biosensor for the determination of glucose to be inserted subcutaneously in vivo, have been compared. Platinum wires with a diameter of 75 mum, teflon-coated were inserted in hypodermic needles and fixed with a two-component epoxy resin. Using a dip-coating procedure, several layers were deposited on electrodes. The first coating was cellulose acetate, the second was immobilized glucose oxidase (GOD) mixed with bovine serum albumin (BSA) and glutaraldheyde, the third coating was a polyurethane coating obtained with commercially available products. A large number of electrodes have been tried and statistically evaluated but they seem to be affected by poor reproducibility evidenced by a large spreading in successive calibration curves. Then, the polyurethane coating has been replaced by a thin polycarbonate membrane salinized and fixed on the tip of the needle. Reproducible results were achieved and first results of in vivo measurements on rabbits are reported.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This data was obtained from an experiment, where polycarbonate (PC) membranes were used to filter two types of organic foulants, including protein and sodium alginate, from suspension in a dead-end filtration cell. These model foulants were stained with fluorescent dyes before filtration. Consequently, a stack of images were captured from the fouling layers on the PC membrane surface using confocal laser scanning microscope (CLSM). This data collection contains 105 2D images of polycarbonate (PC) membranes fouling layer. This data collection would be useful to investigate membrane fouling mechanism by membrane materials researchers and water researchers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This data collection contains 126 images of polycarbonate (PC) membranes fouling layer where two types of organic foulants including protein and yeast present.

This data collection would be useful to investigate membrane fouling mechanism by membrane materials researchers and water researchers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This data collection contains 110 images of polycarbonate (PC) membranes fouling layer where three types of organic foulants including yeast, protein and sodium alginate present.

This data collection would be useful to investigate membrane fouling mechanism by membrane materials researchers and water researchers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of polycarbonate (PC) membrane fouled by two types of organic foulants, protein and sodium alginate. In this experiement, polycarbonate (PC) membrane was used to filter those organic foulants from suspensions in a dead-end stirred cell. The organic foulants were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PC membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. It contains image data of polycarbonate (PC) membranes' fouling layer when two types of organic foulants (protein and sodium alginate) are present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. This data collection would be useful to researchers evaluating the backwashing efficiency of PC membrane in order to optimize frequency and operational conditions of backwashing by membrane materials researchers and by water..

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of polycarbonate (PC) membrane fouled by three types of organic foulants, protein, sodium alginate and yeast. In this experiement, polycarbonate (PC) membrane was used to filter those organic foulants from suspensions in a dead-end stirred cell. The organic foulants were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PC membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. It contains image data of polycarbonate (PC) membranes' fouling layer when three types of organic foulants (protein, sodium alginate and yeast) are present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. This data collection would be useful to researchers who are evaluating the backwashing efficiency of PC membrane in order to optimize frequency and operational conditions of backwashing by membrane materials and by water..

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of polycarbonate (PC) membrane fouled by two types of organic foulants, protein and yeast. In this experiment, polycarbonate (PC) membrane was used to filter those organic foulants from suspensions in a dead-end stirred cell. The organic foulants were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PC membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. It contains image data of polycarbonate (PC) membranes' fouling layer when two types of organic foulants (protein and yeast) present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. This data collection would be useful to researchers evaluating the backwashing efficiency of PC membrane in order to optimize frequency and operational conditions of backwashing by membrane materials and by water.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This collection is the result of an investigation into the backwashing efficiency of polycarbonate (PC) membrane fouled by two types of organic foulants, sodium alginate and yeast. In this experiement, polycarbonate (PC) membrane was used to filter those organic foulants from suspensions in a dead-end stirred cell. The organic foulants were stained with fluorescent dyes before filtration. After filtration, the PC membrane was backwashed. Consequently, a stack of images were captured from the fouling layers on the PC membrane surface using confocal laser scanning microscope (CLSM) and its associated image acquisition software. It contains image data of polycarbonate (PC) membranes' fouling layer when two types of organic foulants (sodium alginate and yeast) present. By comparing with the same membrane without backwashing, the efficiency of backwashing was computed. This data collection would be useful to researchers evaluating the backwashing efficiency of PC membrane in order to optimize frequency and operational conditions of backwashing by membrane materials and by water..

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a method to test the cytotoxicity of wound dressings, ointments, creams and gels used in our Burn Centre, by placing them on a permeable Nunc Polycarbonate cell culture insert, incubated with a monolayer of cells (HaCaTs and primary human keratinocytes). METHODS: We performed two different methods to determine the relative toxicity to cells. (1) Photo visualisation: The dressings or compounds were positioned on the insert's membrane which was placed onto the monolayer tissue culture plate. After 24 h the surviving adherent cells were stained with Toluidine Blue and photos of the plates were taken. The acellular area of non-adherent dead cells which had been washed off with buffer was measured as a percentage of the total area of the plate. (2) Cell count of surviving cells: After 24 h incubation with the test material, the remaining cells were detached with trypsin, spun down and counted in a Haemocytometer with Trypan Blue, which differentiates between live and dead cells. RESULTS: Seventeen products were tested. The least cytotoxic products were Melolite, White soft Paraffin and Chlorsig1% Ointment. Some cytotoxicity was shown with Jelonet, Mepitel((R)), PolyMem((R)), DuoDerm((R)) and Xeroform. The most cytotoxic products included those which contained silver or Chlorhexidine and Paraffin Cream a moisturizer which contains the preservative Chlorocresol. CONCLUSION: This in vitro cell culture insert method allows testing of agents without direct cell contact. It is easy and quick to perform, and should help the clinician to determine the relative cytotoxicity of various dressings and the optimal dressing for each individual wound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For controlled caffeine release, light-responsive membranes were developed. It was possible to produce membranes that reduced their caffeine permeability resistance by about 97% when irradiated with UV-light compared to measurements at daylight. This was achieved by grafting polymers possessing photochromic units onto track-edged polycarbonate membranes. Covalently linked coatings on porous polycarbonate membranes were obtained by plasma activation of the membrane surface followed by plasma-induced graft polymerization. Copolymerization of spiro-compounds during the coating process as well as postmodification of preformed coatings with spiropyran resulted in photochromic membranes. For the copolymerization process, the synthesis of five photochromic methacrylic and acrylic spiropyrans and spirooxazines was successfully performed. Additionally, a spiropyran with carboxylic acid functionality was synthesized for the postmodification process. This enabled us to postmodify polymeric materials containing alcohol or amine groups to obtain photochromic materials. UV-irradiation of these light-responsive membranes resulted in a strong colouration of the membrane, in a reduction of surface tension, which resulted in a decreased caffeine permeability resistance. The membranes were characterized using XPS for the elemental composition of the coating, contact angle measurements for the surface tension, solid-state UV/VIS measurements for the determination of the kinetic and stability properties, and two-photon microscopy for the localisation of the photochromic substance in the porous membrane.