877 resultados para gain coefficient
Resumo:
AIM: Managing neonatal Bartter syndrome by achieving adequate weight gain is challenging. We assessed the correlation between weight gain in neonatal Bartter syndrome and the introduction of fluid and sodium supplementations and indomethacin during the first 4 weeks of life. METHODS: Daily fluid and electrolytes requirements were analysed using linear regression and Spearman correlation coefficients. The weight gain coefficient was calculated as daily weight gain after physiological neonatal weight loss. RESULTS: We studied seven infants. The highest weight gain coefficients occurred between weeks two and four in the five neonates who either received prompt amounts of fluid (maximum 810 mL/kg/day) and sodium (maximum 70 mmol/kg/day) or were treated with indomethacin. For the two patients with the highest weight gain coefficient, water and sodium supplementations were decreased in weeks two to four leading to a significant negative Spearman correlation between weight gain and fluid supplements (r = -0.55 and -0.68) and weight gain and sodium supplementations (r = -0.96 and -0.72). The two patients with the lowest weight gain coefficient had positive Spearman correlation coefficients between weight gain and fluid and sodium supplementations. CONCLUSION: Infants with neonatal Bartter syndrome required rapid and enormous fluid and sodium supplementations or the early introduction of indomethacin treatment to achieve adequate weight gain during the early postnatal period.
Resumo:
Our hypothesis is that iron accumulated in tissue, rather than in serum, may compromise cardiovascular control. Male Fischer 344 rats weighing 180 to 220 g were divided into 2 groups. In the serum iron overload group (SIO, N = 12), 20 mg elemental iron was injected ip daily for 7 days. In the tissue iron overload group (TIO, N = 19), a smaller amount of elemental iron was injected (10 mg, daily) for 5 days followed by a resting period of 7 days. Reflex heart rate responses were elicited by iv injections of either phenylephrine (0.5 to 5.0 µg/kg) or sodium nitroprusside (1.0 to 10.0 µg/kg). Baroreflex curves were determined and fitted to sigmoidal equations and the baroreflex gain coefficient was evaluated. To evaluate the role of other than a direct effect of iron on tissue, acute treatment with the iron chelator deferoxamine (20 mg/kg, iv) was performed on the TIO group and the baroreflex was re-evaluated. At the end of the experiments, evaluation of iron levels in serum confirmed a pronounced overload for the SIO group (30-fold), in contrast to the TIO group (2-fold). Tissue levels of iron, however, were higher in the TIO group. The SIO protocol did not produce significant alterations in the baroreflex curve response, while the TIO protocol produced a nearly 2-fold increase in baroreflex gain (-4.34 ± 0.74 and -7.93 ± 1.08 bpm/mmHg, respectively). The TIO protocol animals treated with deferoxamine returned to sham levels of baroreflex gain (-3.7 ± 0.3 sham vs -3.6 ± 0.2 bpm/mmHg) 30 min after the injection. Our results indicate an effect of tissue iron overload on the enhancement of baroreflex sensitivity.
Resumo:
Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene.
Resumo:
Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene
Resumo:
PURPOSE: To analyze the usefulness of the weight gain/height gain ratio from birth to two and three years of age as a predictive risk indicator of excess weight at preschool age. METHODS: The weight and height/length of 409 preschool children at daycare centers were measured according to internationally recommended rules. The weight values and body mass indices of the children were transformed into a z-score per the standard method described by the World Health Organization. The Pearson correlation coefficients (rP) and the linear regressions between the anthropometric parameters and the body mass index z-scores of preschool children were statistically analyzed (alpha = 0.05). RESULTS: The mean age of the study population was 3.2 years (± 0.3 years). The prevalence of excess weight was 28.8%, and the prevalence of overweight and obesity was 8.8%. The correlation coefficients between the body mass index z-scores of the preschool children and the birth weights or body mass indices at birth were low (0.09 and 0.10, respectively). There was a high correlation coefficient (rP = 0.79) between the mean monthly gain of weight and the body mass index z-score of preschool children. A higher coefficient (rP = 0.93) was observed between the ratio of the mean weight gain per height gain (g/cm) and the preschool children body mass index z-score. The coefficients and their differences were statistically significant. CONCLUSION: Regardless of weight or length at birth, the mean ratio between the weight gain per g/cm of height growth from birth presented a strong correlation with the body mass index of preschool children. These results suggest that this ratio may be a good indicator of the risk of excess weight and obesity in preschool-aged children.
Resumo:
In this thesis, optical gain measurement setup based on variable stripe length method is designed, implemented and improved. The setup is characterized using inorganic and organic samples. The optical gain of spiro-quaterphenyl is calculated and compared with measurements from the setup. Films with various thicknesses of spiro-quaterphenyl, methoxy-spiro-quaterphenyl and phenoxy-spiro-quaterphenyl are deposited by a vacuum vapor deposition technique forming asymmetric slab waveguides. The optical properties, laser emission threshold, optical gain and loss coefficient for these films are measured. Additionally, the photodegradation during pumping process is investigated.
Resumo:
Software metrics offer us the promise of distilling useful information from vast amounts of software in order to track development progress, to gain insights into the nature of the software, and to identify potential problems. Unfortunately, however, many software metrics exhibit highly skewed, non-Gaussian distributions. As a consequence, usual ways of interpreting these metrics --- for example, in terms of "average" values --- can be highly misleading. Many metrics, it turns out, are distributed like wealth --- with high concentrations of values in selected locations. We propose to analyze software metrics using the Gini coefficient, a higher-order statistic widely used in economics to study the distribution of wealth. Our approach allows us not only to observe changes in software systems efficiently, but also to assess project risks and monitor the development process itself. We apply the Gini coefficient to numerous metrics over a range of software projects, and we show that many metrics not only display remarkably high Gini values, but that these values are remarkably consistent as a project evolves over time.
Resumo:
Recently, the concept of a random distributed feedback (DFB) lasing in optical fibers has been demonstrated [1], A number of different random DFB fiber lasers has been demonstrated so far including tunable, multiwalength, cascaded generation, generation in different spectral bands etc [2-7]. All systems are based on standard low-loss germanium doped silica core fibres having relatively low Rayleigh scattering coefficient. Thus, the typical length of random DFB fiber lasers is in the range from several kilometres to tens of kilometres to accumulate enough random feedback. Here we demonstrate for the first time to our knowledge the random DFB fiber laser based on a nitrogen doped silica core (N-doped) fiber. The fiber has several times higher Rayleigh scattering coefficient compared to standard telecommunication fibres. Thus, the generation is achieved in 500 meters long fiber only. © 2013 IEEE.
Resumo:
In the current study, a new approach has been developed for correcting the effect that moisture reduction after virgin olive oil (VOO) filtration exerts on the apparent increase of the secoiridoid content by using an internal standard during extraction. Firstly, two main Spanish varieties (Picual and Hojiblanca) were submitted to industrial filtration of VOOs. Afterwards, the moisture content was determined in unfiltered and filtered VOOs, and liquid-liquid extraction of phenolic compounds was performed using different internal standards. The resulting extracts were analyzed by HPLC-ESI-TOF/MS, in order to gain maximum information concerning the phenolic profiles of the samples under study. The reduction effect of filtration on the moisture content, phenolic alcohols, and flavones was confirmed at the industrial scale. Oleuropein was chosen as internal standard and, for the first time, the apparent increase of secoiridoids in filtered VOO was corrected, using a correction coefficient (Cc) calculated from the variation of internal standard area in filtered and unfiltered VOO during extraction. This approach gave the real concentration of secoiridoids in filtered VOO, and clarified the effect of the filtration step on the phenolic fraction. This finding is of great importance for future studies that seek to quantify phenolic compounds in VOOs.
Resumo:
To analyze the relationship between parity, pre-pregnancy body mass index (BMI), and gestational weight gain (GWG). This observational controlled study was conducted from November 2013 to April 2014, with postpartum women who started antenatal care up to 14 weeks and had full-term births. Data were collected from medical records and antenatal cards. Descriptive and bivariate analyses were performed. The significance level was 5%. Data were collected from 130 primiparous and 160 multiparous women. At the beginning of prenatal care, 54.62% of the primiparous were eutrophic, while the majority of multiparous were overweight or obese (62.51%). Multiparas are two times more likely to be obese at the beginning of their pregnancies, when compared to primiparas. The average pre-pregnancy weight and final pregnancy weight was significantly higher in multiparous, however, the mean GWG was higher among primiparous. We found an inverse correlation between parity and the total GWG, but initial BMI was significantly higher in multiparas. Nevertheless, monitoring of the GWG through actions that promote a healthier lifestyle is needed, regardless of parity and nutritional status, in order to prevent excessive GWG and postpartum weight retention and consequently inadequate pre-pregnancy nutritional status in future pregnancies.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.
Resumo:
Hardy-Weinberg Equilibrium (HWE) is an important genetic property that populations should have whenever they are not observing adverse situations as complete lack of panmixia, excess of mutations, excess of selection pressure, etc. HWE for decades has been evaluated; both frequentist and Bayesian methods are in use today. While historically the HWE formula was developed to examine the transmission of alleles in a population from one generation to the next, use of HWE concepts has expanded in human diseases studies to detect genotyping error and disease susceptibility (association); Ryckman and Williams (2008). Most analyses focus on trying to answer the question of whether a population is in HWE. They do not try to quantify how far from the equilibrium the population is. In this paper, we propose the use of a simple disequilibrium coefficient to a locus with two alleles. Based on the posterior density of this disequilibrium coefficient, we show how one can conduct a Bayesian analysis to verify how far from HWE a population is. There are other coefficients introduced in the literature and the advantage of the one introduced in this paper is the fact that, just like the standard correlation coefficients, its range is bounded and it is symmetric around zero (equilibrium) when comparing the positive and the negative values. To test the hypothesis of equilibrium, we use a simple Bayesian significance test, the Full Bayesian Significance Test (FBST); see Pereira, Stern andWechsler (2008) for a complete review. The disequilibrium coefficient proposed provides an easy and efficient way to make the analyses, especially if one uses Bayesian statistics. A routine in R programs (R Development Core Team, 2009) that implements the calculations is provided for the readers.
Resumo:
Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.