932 resultados para depth-of-focus


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis we have developed solutions to common issues regarding widefield microscopes, facing the problem of the intensity inhomogeneity of an image and dealing with two strong limitations: the impossibility of acquiring either high detailed images representative of whole samples or deep 3D objects. First, we cope with the problem of the non-uniform distribution of the light signal inside a single image, named vignetting. In particular we proposed, for both light and fluorescent microscopy, non-parametric multi-image based methods, where the vignetting function is estimated directly from the sample without requiring any prior information. After getting flat-field corrected images, we studied how to fix the problem related to the limitation of the field of view of the camera, so to be able to acquire large areas at high magnification. To this purpose, we developed mosaicing techniques capable to work on-line. Starting from a set of overlapping images manually acquired, we validated a fast registration approach to accurately stitch together the images. Finally, we worked to virtually extend the field of view of the camera in the third dimension, with the purpose of reconstructing a single image completely in focus, stemming from objects having a relevant depth or being displaced in different focus planes. After studying the existing approaches for extending the depth of focus of the microscope, we proposed a general method that does not require any prior information. In order to compare the outcome of existing methods, different standard metrics are commonly used in literature. However, no metric is available to compare different methods in real cases. First, we validated a metric able to rank the methods as the Universal Quality Index does, but without needing any reference ground truth. Second, we proved that the approach we developed performs better in both synthetic and real cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal blurring resulting from the human eye's depth of focus has been shown to assist visual perception. Infinite focal depth within stereoscopically displayed virtual environments may cause undesirable effects, for instance, objects positioned at a distance in front of or behind the observer's fixation point will be perceived in sharp focus with large disparities thereby causing diplopia. Although published research on incorporation of synthetically generated Depth of Field (DoF) suggests that this might act as an enhancement to perceived image quality, no quantitative testimonies of perceptional performance gains exist. This may be due to the difficulty of dynamic generation of synthetic DoF where focal distance is actively linked to fixation distance. In this paper, such a system is described. A desktop stereographic display is used to project a virtual scene in which synthetically generated DoF is actively controlled from vergence-derived distance. A performance evaluation experiment on this system which involved subjects carrying out observations in a spatially complex virtual environment was undertaken. The virtual environment consisted of components interconnected by pipes on a distractive background. The subject was tasked with making an observation based on the connectivity of the components. The effects of focal depth variation in static and actively controlled focal distance conditions were investigated. The results and analysis are presented which show that performance gains may be achieved by addition of synthetic DoF. The merits of the application of synthetic DoF are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN]This work presents a comparison among different focus measures used in the literature for autofocusing in a non previously explored application of face detection. This application has different characteristics to those where traditionally autofocus methods have been applied like microscopy or depth from focus. The aim of the work is to find if the best focus measures in traditional applications of autofocus have the same performance in face detection applications. To do that six focus measures has been studied in four different settings from the oldest to more recent ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the measurement of the depth of maximum, X(max), of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10(18) eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106 +/- 35-21) g/cm(2)/decade below 10(18.24) +/- (0.05) eV, and d24 +/- 3 g/cm(2)/ecade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm(2). The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study concerns the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropylvinylether) (PFA) substrates and the penetration depth of the graft. Grafting was obtained by the simultaneous irradiation method, and the spectroscopic analysis was made with the micro-Raman technique. Effects of grafting conditions such as the type of solvent, dose rate, and irradiation dose on the grafting yield were investigated. Of the different solvents used, the most efficient in terms of increasing grafting yield were dichloromethane, benzene, and methanol, respectively. A mixture of methanol and dichloromethane used as a solvent for styrene achieved a higher degree of grafting and concentration of grafted polystyrene onto the surface of PFA substrates than solutions of the monomer in the separate solvents. The degree of grafting increased with increasing radiation dose up to 500 kGy, stabilizing above this dose. However, the grafting yield decreased with an increase in the dose rate. The increase in the overall grafting yield was accompanied by a proportional increase in the penetration depth of the grafts into the substrate. (C) 2002 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

v.36:no.2(1956)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blowflies use discrete, ephemeral breeding sites for larval nutrition. After exhaustion of the food supply, the larvae disperse in search of sites to pupate or to seek other sources of food in a process known as post-feeding larval dispersal. In this study, some of the most important aspects of this process were investigated in larvae of the blowflies Chrysomya megacephala exposed to a variety of light: dark (LD) cycles (0:0 h, 12:12 h and 24:0 h) and incubated in tubes covered with vermiculite. For each pupa, the body weight and depth of burrowing were determined. Statistical tests were used to examine the relationship of depth of burrowing and body weight to photoperiod at which burrowing occurred. The study of burial behavior in post-feeding larval dispersing can be useful for estimating the postmortem interval (PMI) of human corpses in forensic medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Let I be an ideal in a local Cohen-Macaulay ring (A, m). Assume I to be generically a complete intersection of positive height. We compute the depth of the Rees algebra and the form ring of I when the analytic deviation of I equals one and its reduction number is also at most one. The formu- las we obtain coincide with the already known formulas for almost complete intersection ideals.