838 resultados para cut-off value


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Waist circumference has been identified as a valuable predictor of cardiovascular risk in children. The development of waist circumference percentiles and cut-offs for various ethnic groups are necessary because of differences in body composition. The purpose of this study was to develop waist circumference percentiles for Chinese children and to explore optimal waist circumference cut-off values for predicting cardiovascular risk factors clustering in this population.----- ----- Methods: Height, weight, and waist circumference were measured in 5529 children (2830 boys and 2699 girls) aged 6-12 years randomly selected from southern and northern China. Blood pressure, fasting triglycerides, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and glucose were obtained in a subsample (n = 1845). Smoothed percentile curves were produced using the LMS method. Receiver-operating characteristic analysis was used to derive the optimal age- and gender-specific waist circumference thresholds for predicting the clustering of cardiovascular risk factors.----- ----- Results: Gender-specific waist circumference percentiles were constructed. The waist circumference thresholds were at the 90th and 84th percentiles for Chinese boys and girls respectively, with sensitivity and specificity ranging from 67% to 83%. The odds ratio of a clustering of cardiovascular risk factors among boys and girls with a higher value than cut-off points was 10.349 (95% confidence interval 4.466 to 23.979) and 8.084 (95% confidence interval 3.147 to 20.767) compared with their counterparts.----- ----- Conclusions: Percentile curves for waist circumference of Chinese children are provided. The cut-off point for waist circumference to predict cardiovascular risk factors clustering is at the 90th and 84th percentiles for Chinese boys and girls, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims The aim of the study was to evaluate the significance of total bilirubin, aspartate transaminase (AST), alanine transaminase and gamma-glutamyltransferase (GGT) for predicting outcome in sepsis-associated cholestasis. Methods: A retrospective cohort review of the hospital records was performed in 181 neonates admitted to the Neonatal Care Unit. A comparison was performed between subjects with low and high liver values based on cut-off values from ROC analysis. We defined poor prognosis to be when a subject had prolonged cholestasis of more than 3.5 months, developed severe sepsis, septic shock or had a fatal outcome. Results: The majority of the subjects were male (56%), preterm (56%) and had early onset sepsis (73%). The poor prognosis group had lower initial values of GGT compared with the good prognosis group (P = 0.003). Serum GGT (cut-off value of 85.5 U/L) and AST (cut-off value of 51 U/L) showed significant correlation with the outcome following multivariate analysis. The odds ratio (OR) of low GGT and high AST were OR 4.3 (95% CI:1.6 to11.8) and OR 2.9 (95% CI:1.1 to 8), respectively, for poor prognosis. In subjects with normal AST values, those with low GGT value had relative risk of 2.52 (95% CI:1.4 to 3.5) for poorer prognosis compared with those with normal or high GGT. Conclusion: Serum GGT and AST values can be used to predict the prognosis of patients with sepsis-associated cholestasis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Body mass index (BMI) is widely used as a measure of adiposity. However, currently used cut-off values are not sensitive in diagnosing obesity in South Asian populations. Aim: To define BMI and waist circumference (WC), cut-off values representing percentage fat mass (%FM) associated with adverse health outcomes. Subjects and methods: A cross-sectional descriptive study of 285 5–14 year old Sri Lankan children (56% boys) was carried out. Fat mass (FM) was assessed using the isotope (D2O) dilution technique based on 2C body composition model. BMI and WC cut-off values were defined based on %FM associated with adverse health outcomes. Results: Sri Lankan children had a low fat free mass index (FFMI) and a high fat mass index (FMI). Individuals with the same BMI had %FM distributed over a wide range. Lean body tissue grew very little with advancing age and weight gain was mainly due to increases in body fat. BMI corresponding to 25% in males and 35% in females at 18 years was 19.2 kg/m2 and 19.7 kg/m2, respectively. WC cut-off values for males and females were 68.4 cm and 70.4 cm, respectively. Conclusion: This chart analysis clearly confirms that Sri Lankan children have a high %FM from a young age. With age, more changes occur in FM than in fat free mass (FFM). Although the newly defined BMI and WC cut-off values appear to be quite low, they are comparable to some recent data obtained in similar populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The exact expressions for the partition function (Q) and the coefficient of specific heat at constant volume (Cv) for a rotating-anharmonic oscillator molecule, including coupling and rotational cut-off, have been formulated and values of Q and Cv have been computed in the temperature range of 100 to 100,000 K for O2, N2 and H2 gases. The exact Q and Cv values are also compared with the corresponding rigid-rotator harmonic-oscillator (infinite rotational and vibrational levels) and rigid-rotator anharmonic-oscillator (infinite rotational levels) values. The rigid-rotator harmonic-oscillator approximation can be accepted for temperatures up to about 5000 K for O2 and N2. Beyond these temperatures the error in Cv will be significant, because of anharmonicity and rotational cut-off effects. For H2, the rigid-rotator harmonic-oscillator approximation becomes unacceptable even for temperatures as low as 2000 K.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comprehensive understanding of the long-term performance of cement-bentonite slurry trench cut-off walls is essential as these mixes may degrade when exposed to aggressive environments or when subjected to prolonged drying. A series of wetting-drying and immersion experiments was carried out to evaluate the durability characteristics of laboratory mixed samples and block field samples from 40 days to 11 years of age. For the wetting-drying tests, the samples buried in medium graded sand were subjected to periodical flooding and drying cycles. They were then used for permeability testing and unconfined compressive strength (UCS) testing. For the immersion tests, the samples confined in perforated molds were submerged in magnesium sulfate solution for 16 weeks and their microstructures were then analyzed using X-ray diffraction (XRD) technique. This paper identifies the effects of contaminant exposure on durability of cement-bentonite and the effects of aging by comparing 11 years old samples to younger samples. Test results showed that young or previously contaminated cement-bentonite mixes are more susceptible to sulfate attack than old or less contaminated mixes. Copyright ASCE 2008.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Top-illuminated metamorphic InGaAs p-i-n photodetectors (PDs) with 50% cut-off wavelength of 1.75 mu m at room temperature are fabricated on GaAs substrates. The PDs are grown by a solid-source molecular beam epitaxy system. The large lattice mismatch strain is accommodated by growth of a linearly graded buffer layer to create a high quality virtual InP substrate indium content in the metamorphic buffer layer linearly changes from 2% to 60%. The dark current densities are typically 5 x 10(-6) A/cm(2) at 0 V bias and 2.24 x 10(-4) A/cm(2) at a reverse bias of 5 V. At a wavelength of 1.55 mu m, the PDs have an optical responsivity of 0.48 A/W, a linear photoresponse up to 5 mW optical power at -4 V bias. The measured -3 dB bandwidth of a 32 mu m diameter device is 7 GHz. This work proves that InGaAs buffer layers grown by solid source MBE are promising candidates for GaAs-based long wavelength devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a detailed study of the capacitance spectra obtained from Au/doped-polyaniline/Al structures in the frequency domain (0.05 Hz-10 MHz), and at different temperatures (150-340 K) is carried out. The capacitance spectra behavior in semiconductors can be appropriately described by using abrupt cut-off models, since they assume that the electronic gap states that can follow the ac modulation have response times varying rapidly with a certain abscissa, which is dependent on both temperature and frequency. Two models based on the abrupt cut-off concept, formerly developed to describe inorganic semiconductor devices, have been used to analyze the capacitance spectra of devices based on doped polyaniline (PANI), which is a well-known polymeric semiconductor with innumerous potential technological applications. The application of these models allowed the determination of significant parameters, such as Debye length (approximate to 20 nm), position of bulk Fermi level (approximate to 320 meV) and associated density of states (approximate to 2x10(18) eV(-1) cm(-3)), width of the space charge region (approximate to 70 nm), built-in potential (approximate to 780 meV), and the gap states` distribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)