751 resultados para corneal topographer
Resumo:
Póster presentado en EDULEARN12, International Conference on Education and New Learning Technologies, Barcelona, 2nd-4th July 2012.
Resumo:
Reverse engineering is the process of discovering the technological principles of a device, object or system through analysis of its structure, function, and operation. From a device used in clinical practice, as the corneal topographer, reverse engineering will be used to infer physical principles and laws. In our case, reverse engineering involves taking this mechanical device apart and analyzing its working detail. The initial knowledge of the application and usefulness of the device provides a motivation that, together with the combination of theory and practice, will help the students to understand and learn concepts studied in different subjects in the Optics and Optometry degree. These subjects belong to both the core and compulsory subjects of the syllabus of first and second year of the degree. Furthermore, the experimental practice is used as transverse axis that relates theoretical concepts, technology transfer and research.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
Réalisé en cotutelle avec Aix Marseille Université.
Resumo:
Abstract Background High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches. In order to evaluate the influence of the irregularity on suturing for the residual astigmatism, a prototype for ophthalmic surgical support has been developed. The final intention of this prototype is to be an evaluation tool for guided suture and as an outcome diminish the postoperative astigmatism. Methods The system consists of hand held ring with 36 infrared LEDs, that is to be projected onto the lachrymal film of the cornea. The image is reflected back through the optics of the ocular microscope and its distortion from the original circular shape is evaluated by developed software. It provides keratometric and circularity measurements during surgery in order to guide the surgeon for uniformity in suturing. Results The system is able to provide up to 23D of astigmatism (32D - 55D range) and is ± 0.25D accurate. It has been tested in 14 volunteer patients intraoperative and has been compared to a commercial keratometer Nidek Oculus Hand-held corneal topographer. The correlation factors are 0.92 for the astigmatism and 0.97 for the associated axis. Conclusion The system is potentially efficient for guiding the surgeon on uniformity of suturing, presenting preliminary data indicating an important decrease on the residual astigmatism, from an average of 8D - for patients not submitted to the prototype guidance - to 1.4D - for patients who have actually been submitted to the prototype guidance - after the first 24 hours post-surgery and in the subsequent weeks. It also indicates that the surgeon should achieve circularity greater or equal to 98% in order to avoid postoperative astigmatisms over 1D. Trial Registration Trial registration number: CAAE - 0212.0.004.000-09.
Resumo:
PURPOSE: To evaluate factors affecting corneoscleral profile (CSP) using Anterior Segment Optical Coherence Tomography (AS-OCT) in combination with conventional videokeratoscopy. METHODS: OCT data were collected from 204 subjects of mean age 34.9 years (SD: ±15.2 yrs, range 18 to 65) using the Zeiss Visante AS-OCT and Medmont M300 corneal topographer. Measurements of corneal diameter (CD), corneal sagittal height (CS), iris diameter (ID), corneoscleral junction angle (CSJ) and scleral radius (SR) were extracted from multiple OCT images. Horizontal visible iris diameter (HVID) and vertical palpebral aperture (PA) were measured using a slit lamp graticule. Subject body height was also measured. Associations were then sought between CSP variables and age, height, ethnicity, sex and refractive error data collected. Results: Significant correlations were found between age and ocular topography variables of HVID, PA, CSJ, SR and ID (P<0.0001), while height correlated with HVID, CD and ID, and power vector terms only with vertical plane keratometry, CD and CS. Significant differences were noted between ethnicities with respect to CD (P=0.0046), horizontal and vertical CS (P=0.0068 and P=0.0095), and also horizontal ID (P=0.0010), while the same variables, with the exception of vertical CS, also varied with sex; horizontal CD (P=0.0018), horizontal CS (P=0.0018) and ID (P=0.0012). Age accounted for up to 36% of the variance in CSP variables. Conclusion: Age is the main factor influencing corneoscleral topography; consequently, this should be taken into consideration in contact lens design, in the optimization of surgical procedures involving the cornea and sclera and in IOL selection.
Resumo:
Background: The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Methods: Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7±9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). Results: The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19±0.36 DS, p<0.01 for sphere; -0.19±0.35 DS, p<0.01 for mean spherical equivalent; -0.002±0.23 DC, p=0.91 for cylinder; -0.06±0.38 DC, p=0.30 for J0 and -0.36±0.31 DC for J45, p=0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within±0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. Conclusion: The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Resumo:
Póster presentado en SPIE Photonics Europe, Brussels, 16-19 April 2012.
Resumo:
Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.
Resumo:
PURPOSE: The main goal of this study was to develop and compare two different techniques for classification of specific types of corneal shapes when Zernike coefficients are used as inputs. A feed-forward artificial Neural Network (NN) and discriminant analysis (DA) techniques were used. METHODS: The inputs both for the NN and DA were the first 15 standard Zernike coefficients for 80 previously classified corneal elevation data files from an Eyesys System 2000 Videokeratograph (VK), installed at the Departamento de Oftalmologia of the Escola Paulista de Medicina, São Paulo. The NN had 5 output neurons which were associated with 5 typical corneal shapes: keratoconus, with-the-rule astigmatism, against-the-rule astigmatism, "regular" or "normal" shape and post-PRK. RESULTS: The NN and DA responses were statistically analyzed in terms of precision ([true positive+true negative]/total number of cases). Mean overall results for all cases for the NN and DA techniques were, respectively, 94% and 84.8%. CONCLUSION: Although we used a relatively small database, results obtained in the present study indicate that Zernike polynomials as descriptors of corneal shape may be a reliable parameter as input data for diagnostic automation of VK maps, using either NN or DA.
Resumo:
PURPOSE: To evaluate the corneal vascularization (CV) and the clinical aspects induced by interlamellar graft with native (NCM) and anionic (ACM) collagen membranes in rabbits corneas. METHODS: An interlamellar graft with a 0.25 x 0.25 cm NCM (group 1) or ACM (group 2) fragment was performed in the right eye (treated eye). In the left eye, an estromal tunnel was done (control eye). Sixteen rabbits were used, and they were subdivided into two experimental groups of eight animals each. The clinical evaluation was performed at the 1st, 3rd, 7th, 15th and 30th postoperative days. Corneal vascularization analysis was performed after 30 days by the Images Analizator System Leica Qwin-550®. RESULTS: After 7 days, corneal vascularization was observed at about 2.25 ± 0.71 mm (NCM) and at about 1.0 ± 1.69 mm (ACM), respectively, from the limbus in direction to the central cornea. After 15 days, CV increased in both groups (5.25 ± 1.03 mm - NCM; 2.0 ± 2.39 mm - ACM) and then progressively decreased until day 30 (2.25 ± 2.10 mm - NCM; 0.75 ± 2.12 mm - ACM). The statistical analysis indicated that the averages of the distances from the limb vessels to the grafts observed after 7 and 15 days had not differed statistically (p=0.17), and after 15 and 30 postoperative days had a tendency to differ statistically (p=0.09). The control eyes did not present any changes. CONCLUSION: The interlamellar graft with native and anionic collagen membranes induced corneal vascularization when applied to rabbit corneas, but anionic collagen membrane induced a smaller corneal vascularization when compared to native collagen membrane. Although further studies are required, the results found in this study demonstrated the usefulness of interlamellar graft with native and anionic collagen membranes in keratoplasties. These membranes consists in one more graft option for the surgical treatment of corneal repair in rabbits and others animals, when other forms of medical and surgical treatment are not effective.
Resumo:
The aim of this study was to examine the endothelial surface morphology and perform a morphometric analysis of the corneal endothelial cells of ostrich (Struthio camelus) using scanning electron microscopy. Polygonality, mean cell area, cell density and coefficient of variation of mean cell area were analyzed. The normal corneal endothelium consisted of polygonal cells of uniform size and shape with few interdigitations of the cell borders. Microvilli appeared as protusions on the cellular surface. The average cell area was 269±18µm² and the endothelial cell density was 3717±240cells mm-2. The coefficient of variation of the cell area was 0.06, and the percentage of hexagonal cells was 75%. The parameters evaluated did not differ significantly between the right and the left eye from the same ostrich. The results of this study showed that the ostrich corneal endothelial cells appear quite similar to those of the other vertebrates.
Resumo:
Objective: The aim of this study was to verify the influence of prostaglandin analogs and prostamide on central corneal thickness (CCT). Methods: A prospective analysis was done of CCT in glautomatous patients submitted to monotherapy with prostaglandin analogs (latanoprost 0.005% or travoprost 0.004%) or prostamide (bimatoprost 0.03%) during an 8-week period. A control group of patients without any ocular medication was also evaluated. CCT measurements were performed with a commercially available ultrasound pachymeter. A total of 73 patients were included in this study. Mean age was 68.5 +/- 9.2 (range, 48-85) years old. Results: A statistically significant reduction in CCT was observed in all groups, except the control group (n = 21): Bimatoprost 0.03% group (n = 21): 544.41 +/- 35.4 vs. 540.35 +/- 35.9 mu m (P = 0.039); travoprost 0.004% group (n = 17): 538.47 +/- 32.0 vs. 532.25 +/- 30.4 mu m (P = 0.009); latanoprost 0.005% group (n = 14): 548.57 +/- 32.4 vs. 543.88 +/- 35.6 mu m (P = 0.036). Conclusion: Topical therapy with prostaglandin analogs and bimatoprost is associated with CCT reduction over a period of at least 8 weeks.
Resumo:
Purpose: To compare the central corneal thickness (CCT) of patients with systemic sclerosis (SSc) and control subjects. Methods: The study group comprised 37 consecutive patients with SSc, and the control group comprised 23 healthy individuals similar in age and sex. CCT value was measured by ultrasound pachymetry. Results: In the SSc group, the mean CCT in the right eye was 534.9 +/- 33.5 mu m and 536.9 +/- 32.4 mu m in the left eye. In the control group, the mean CCT was 533.0 +/- 32.9 mu m in the right eye and 533.1 +/- 33.6 mu m in the left eye. The mean CCT was not significantly different in the SSc group compared with the control group for both the right (P = 0.83) and left (P = 0.67) eyes. Conclusions: CCT measurements do not significantly differ in patients with SSc compared with healthy control subjects.