996 resultados para commercial sensitivity


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ireland is a latecomer to Public Private Partnership (PPP) having only adopted it in 1998. Prior to the credit crisis, Ireland followed the UK model with PPPs being implemented in transport, education, housing/urban regeneration and water/wastewater. Having stalled during the credit crisis, PPP has been reactivated recently with the domestic infrastructure stimulus programme . The focus of this paper is on Ireland as a younger participant in PPP and the nexus between adoption patterns and sustainability characteristics of Irish PPP. Using document analysis and exploratory interviews, the paper examines the reasons for Ireland’s interest in PPP which cannot be attributed to economic rationales alone. We consider three explanations: voluntary adoption – where the UK model was closely followed as part of a domestic modernisation agenda; coercive adoption – where PPP policy was forced upon public sector organisations; and institutional isomorphism – where institutional creation and change around PPP was promoted to help public sector organisations gain institutional legitimacy. We find evidence of all three patterns with coercive adoption becoming more relevant in recent years, which is likely to affect sustainability adversely unless incentives for voluntary adoption are strengthened and institutional capacity building is boosted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Obtaining ecotoxicological data on pesticides in tropical regions is imperative for performing more realistic risk analysis, and avoidance tests have been proposed as a useful, fast and cost-effective tool. Therefore, the present study aimed to evaluate the avoidance behavior of Eisenia andrei to a formulated product, Vertimec(A (R)) 18 EC (a.i abamectin), in tests performed on a reference tropical artificial soil (TAS), to derive ecotoxicological data on tropical conditions, and a natural soil (NS), simulating crop field conditions. In TAS tests an adaptation of the substrate recommended by OECD and ISO protocols was used, with residues of coconut fiber as a source of organic matter. Concentrations of the pesticide on TAS test ranged from 0 to 7 mg abamectin/kg (dry weight-d.w.). In NS tests, earthworms were exposed to samples of soils sprayed in situ with: 0.9 L of Vertimec(A (R)) 18 EC/ha (RD); twice as much this dosage (2RD); and distilled water (Control), respectively, and to 2RD: control dilutions (12.5, 25, 50, 75%). All tests were performed under 25 +/- A 2A degrees C, to simulate tropical conditions, and a 12hL:12hD photoperiod. The organisms avoided contaminated TAS for an EC50,48h = 3.918 mg/kg soil d.w., LOEC = 1.75 mg/kg soil d.w. and NOEC = 0.85 mg/kg soil d.w. No significant avoidance response occurred for any NS test. Abamectin concentrations in NS were rather lower than EC50, 48h and LOEC determined in TAS tests. The results obtained contribute to overcome a lack of ecotoxicological data on pesticides under tropical conditions, but more tests with different soil invertebrates are needed to improve pesticides risk analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microemulsion electrokinetic capillary chromatography has been successfully applied to the separation and determination of water-soluble vitamins (thiamine hydrochloride, riboflavin, niacin, pyridoxine hydrochloride, folic acid, cobalamin, ascorbic acid) and a fat-soluble vitamin (alpha-tocopherol acetate). The optimal microemulsion buffer contained sodium dodecylsulfate (SDS) as surfactant, butan-1-ol as the co-surfactant, ethyl acetate as the oil and pH 9.2 tetraborate buffer, modified with 15% (v/v) 2-propanol. UV detection at 214 nm gave adequate sensitivity without interference from sample excipients. Under the optimized conditions, the vitamins were baseline separated in less than 7 min. Analytical curves of peak area versus concentration presented coefficients of determination (R (2) ) > 0.99, acceptable limits of quantification between 8.40 and 16.23 mu g mL(-1) were obtained. Vitamin levels in liquid formulation were quantified with intra-day precision better than 0.99% RSD for migration time and 1.19% RSD for peak area ratio. Recoveries ranged between 98.7 and 101.7%. The method was considered appropriate for rapid and routine analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. Methods: The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). Results: The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa=0.70; kappa p=0.001; McNemar p=1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. Conclusions: the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies. (Clin. Lab. 2010;56:29-35)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Shrimp is a frequent cause of food allergy. Tropomyosin is the major allergen in shrimp, and it shares homology to tropomyosins from other crustaceans, dust mites, cockroach, and parasites. Objective: The aim of this study was to determine the value of detection of IgE to shrimp tropomyosin in the diagnosis of shrimp allergy. Methods: We have studied 35 patients with asthma, rhinitis, or both who were sensitized to Dermatophagoides pteronyssinus. All subjects underwent skin prick testing in addition to double-blind, placebo-controlled food challenges (DBPCFC); oral open challenges; or both with shrimp. Measurements of IgE to shrimp and shrimp tropomyosin were carried out by means of CAP and chimeric ELISA, respectively. Results: Oral challenges confirmed the diagnosis of shrimp allergy in 7 patients. IgE measurement to shrimp tropomyosin was positive in 71.4% of the patients with shrimp allergy. Of the 28 patients without shrimp allergy, only 7.1% (2/28) had IgE to shrimp tropomyosin compared with 25% (7/28) who had IgE to shrimp and 35.7% (10/28) who had positive skin prick test responses to shrimp. Sensitivity was similar for all 3 methods (71.4%); in contrast, specificity of IgE to shrimp tropomyosin (92.8%) was greater than that of IgE to shrimp (75%) and skin prick testing (64.2%). With regard to diagnostic efficiency, measurement of IgE to shrimp tropomyosin was superior to measurement of IgE to shrimp and skin prick testing (88.5%, 74.2%, and 65.7%, respectively). Conclusion: Use of measurements of IgE to shrimp tropomyosin provided added value to the diagnosis of shrimp allergy. (J Allergy Clin Immunol 2010;125:872-8.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High speed trains, when crossing regions with abrupt changes in vertical stiffness of the track and/or subsoil, may generate excessive ground and track vibrations. There is an urgent need for specific analyses of this problem so as to allow reliable esimates of vibration amplitude. Full understanding of these phenomena will lead to new construction solutions and mitigation of undesirable features. In this paper analytical transient solutions of dynamic response of one-dimensional systems with sudden change of foundation stiffness are derived. Results are expressed in terms of vertical displacement. Sensitivity analysis of the response amplitude is also performed. The analytical expressions presented herein, to the authors’ knowledge, have not been published yet. Although related to one-dimensional cases, they can give useful insight into the problem. Nevertheless, in order to obtain realistic response, vehicle- rail interaction cannot be omitted. Results and conclusions are confirmed using general purpose commercial software ANSYS. In conclusion, this work contributes to a better understanding of the additional vibration phenomenon due to vertical stiffness variation, permitting better control of the train velocity and optimization of the track design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional molecular techniques for detection and characterization of relevant nucleic acid (i.e. DNA) sequences are, nowadays, cumbersome, expensive and with reduced portability. The main objective of this dissertation consisted in the optimization and validation of a fast and low-cost colorimetric nanodiagnostic methodology for the detection of single nucleotide polymorphisms (SNPs). This was done considering SNPs associated to obesity of commercial interest for STAB VIDA, and subsequent evaluation of other clinically relevant targets. Also, integration of this methodology into a microfluidic platform envisaging portability and application on points-of-care (POC) was achieved. To warrant success in pursuing these objectives, the experimental work was divided in four sections: i) genetic association of SNPs to obesity in the Portuguese population; ii) optimization and validation of the non-cross-linking approach for complete genotype characterization of these SNPs; iii) incorporation into a microfluidic platform; and iv) translation to other relevant commercial targets. FTO dbSNP rs#:9939609 carriers had higher body mass index (BMI), total body fat mass, waist perimeter and 2.5 times higher risk to obesity. AuNPs functionalized with thiolated oligonucleotides (Au-nanoprobes) were used via the non-cross-linking to validate a diagnostics approach against the gold standard technique - Sanger Sequencing - with high levels of sensitivity (87.50%) and specificity (91.67%). A proof-of-concept POC microfluidic device was assembled towards incorporation of the molecular detection strategy. In conclusion a successful framework was developed and validated for the detection of SNPs with commercial interest for STAB VIDA, towards future translation into a POC device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chronic Chagas disease diagnosis relies on laboratory tests due to its clinical characteristics. The aim of this research was to review commercial enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR) diagnostic test performance. Performance of commercial ELISA or PCR for the diagnosis of chronic Chagas disease were systematically searched in PubMed, Scopus, Embase, ISI Web, and LILACS through the bibliography from 1980-2014 and by contact with the manufacturers. The risk of bias was assessed with QUADAS-2. Heterogeneity was estimated with the I2 statistic. Accuracies provided by the manufacturers usually overestimate the accuracy provided by academia. The risk of bias is high in most tests and in most QUADAS dimensions. Heterogeneity is high in either sensitivity, specificity, or both. The evidence regarding commercial ELISA and ELISA-rec sensitivity and specificity indicates that there is overestimation. The current recommendation to use two simultaneous serological tests can be supported by the risk of bias analysis and the amount of heterogeneity but not by the observed accuracies. The usefulness of PCR tests are debatable and health care providers should not order them on a routine basis. PCR may be used in selected cases due to its potential to detect seronegative subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pneumocystis jirovecii pneumonia (PCP) is a common opportunistic infection. Microscopic diagnosis, including diagnosis using the Merifluor-Pneumocystis direct fluorescent antigen (MP-DFA) test, has limitations. Real-time PCR may assist in diagnosis, but no commercially validated real-time PCR assay has been available to date. MycAssay Pneumocystis is a commercial assay that targets the P. jirovecii mitochondrial large subunit (analytical detection limit, ≤3.5 copies/μl of sample). A multicenter trial recruited 110 subjects: 54 with transplants (40 with lung transplants), 32 with nonmalignant conditions, 13 with leukemia, and 11 with solid tumors; 9 were HIV positive. A total of 110 respiratory samples (92% of which were bronchoalveolar lavage [BAL] specimens) were analyzed by PCR. Performance was characterized relative to investigator-determined clinical diagnosis of PCP (including local diagnostic tests), and PCR results were compared with MP-DFA test results for 83 subjects. Thirteen of 14 subjects with PCP and 9/96 without PCP (including 5 undergoing BAL surveillance after lung transplantation) had positive PCR results; sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) were 93%, 91%, 59%, and 99%, respectively. Fourteen of 83 subjects for whom PCR and MP-DFA test results were available had PCP; PCR sensitivity, specificity, PPV, and NPV were 93%, 90%, 65%, and 98%, respectively, and MP-DFA test sensitivity, specificity, PPV, and NPV were 93%, 100%, 100%, and 98%. Of the 9 PCR-positive subjects without PCP, 1 later developed PCP. The PCR diagnostic assay compares well with clinical diagnosis using nonmolecular methods. Additional positive results compared with the MP-DFA test may reflect low-level infection or colonization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Screening for Chlamydia trachomatis-specific antibodies is valuable in investigating recurrent miscarriage, tubal infertility and extrauterine pregnancy. We compared here the performance of immunofluorescence (IF) to four other commercial tests in detecting IgG antibodies directed against C. trachomatis: two enzyme-linked immunosorbent assays (ELISAs) using the major outer membrane protein (MOMP) as the antigen, commercialised respectively by Medac and R-Biopharm (RB), one ELISA using the chlamydial heat shock protein 60 (cHSP60) as the antigen (Medac), as well as a new automated epifluorescence immunoassay (InoDiag). A total of 405 patients with (n = 251) and without (n = 154) miscarriages were tested by all five tests. The prevalence of C. trachomatis-specific IgG antibodies as determined by the IF, cHSP60-Medac, MOMP-Medac, MOMP-RB and InoDiag was 14.3, 23.2, 14.3, 11.9 and 26.2%, respectively. InoDiag exhibited the highest sensitivity, whereas MOMP-RB showed the best specificity. Cross-reactivity was observed with C. pneumoniae using IF, MOMP-RB and InoDiag, and Parachlamydia acanthamoebae using the cHSP60 ELISA test. No cross-reactivity was observed between C. trachomatis and the other Chlamydiales (Neochlamydia hartmannellae, Waddlia chondrophila and Simkania negevensis). Given its high sensitivity, the new automated epifluorescence immunoassay from InoDiag represents an interesting alternative. The MOMP-based ELISA of R-Biopharm should be preferred for large serological studies, given the high throughput of ELISA and its excellent specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experiments were carried out in a growth chamber with controlled temperature and photoperiod to test two populations of Blumeria graminis f. sp. hordei from Guarapuava, Paraná State, and Passo Fundo, Rio Grande do Sul State, Brazil. Treatments consisted in application of the fungicide triadimenol (Baytan 150 SC®) at three rates of its commercial formulation: 150, 250, 350 mL/100 Kg barley seeds. The experiments were conducted separately in a growth chamber for each population, adopting the same temperature and photoperiod. For inoculation, pots containing barley seedlings colonized by the fungus were placed among the plots. After emergence of the first symptoms, the disease severity was assessed at two-day intervals. The experiments were repeated twice for each fungus population. Data were expressed as area under the disease progress curve and as powdery mildew control by comparing the severity after the fungicide treatments to that of control. Data were subjected to analysis of variance and regression analysis; the area under the disease progress curve was also calculated. Comparing the data obtained in the present study with those reported in the literature and the control, the maximum value of 26.1% is considered insufficient to prevent the damages caused by the disease. The control response to the fungicide rate was significant. We can conclude that there was a reduction in the sensitivity of both B. graminis f.sp. hordei populations to the fungicide triadimenol, which explains the control failure observed in barley farms.