948 resultados para Time-resolved methods
Resumo:
The formation of nitrogen oxides (NOx) during a combustion process is difficult to avoid because of the large exotherm and the consequent problem of avoiding local high-temperature spikes. Consequently, for many applications, such as for automotive power generation, there will be a continuing need to use catalytic after-treatment to reduce harmful emissions. The investigation of the mechanisms of the key catalytic reactions in environmental catalysis can provide an insight into the action of the catalyst, and time-resolved methods offer a powerful means to study these processes under realistic conditions. The use of Temporal Analysis of Products (TAP) and Steady State Isotopic Transient Kinetic Analysis (SSITKA) methods to investigate the reduction of NOx under various experimental conditions is described. From a detailed analysis of the SSITKA profiles, it is shown that at low temperatures the mechanism for the formation of N-2 and N2O from NO may differ from the conventional high-temperature mechanism. This is supported by density functional theory calculations, which show that the barrier to the formation of N2O from the reaction of N(ads) and NO(ads) may be too high to allow this process to occur at low temperatures. The alternative reaction of NO(ads) + NO(ads) = N2O(g) + O(ads) is shown to be much more favorable and is consistent with the SSITKA analysis. The remarkable effect of hydrogen as a reductant at low temperatures is described, and alternative interpretations of the role of hydrogen are discussed.
Resumo:
Resonance Raman spectra of the T-1 excited states of Zn and free-base tetra-4-sulfonatophenylporphyrin (TPPS) have been recorded at room temperature in aqueous solution using two-colour time-resolved methods. The spectra of both sulfonated molecules are very similar to their tetraphenylporphyrin (TPP) analogues, which have been recorded in THF solution using the same pump-probe conditions, but they have higher signal-to-noise ratios because interference from strong solvent bands is reduced. Although two different T-1 spectra of Zn(TPP) have been reported these spectra differ slightly from each other and from the spectrum reported here, which has band positions very close (+/-6 cm(-1)) to those of Zn(TPPS). The high S/N ratios obtainable for the water-soluble porphyrins have allowed reliable polarization data to be recorded for their S-0 and T-1 states. This data set allows a realistic comparison of the changes in bonding associated with excitation of both free-base and Zn tetraarylporphyrins to the T-1 state.
Resumo:
The XAS/WAXS time-resolved method was applied for unraveling the complex mechanisms arising from the evolution of several metastable intermediates during the degradation of chlorine layered double hydroxide (LDH) upon heating to 450 °C, i.e., Zn2Al(OH)6·nH2O, ZnCuAl(OH)6·nH2O, Zn2Al 0.75Fe0.25(OH)6·nH2O, and ZnCuAl0.5Fe0.5(OH)6·nH2O. After a contraction of the interlamellar distance, attributed to the loss of intracrystalline water molecules, this distance experiences an expansion (T > 175-225 °C) before the breakdown of the lamellar framework around 275-295 °C. Amorphous prenucleus clusters with crystallo-chemical local order of zinc-based oxide and zinc-based spinel phases, and if any of copper-based oxide, are formed at T > 175-225 °C well before the loss of stacking of LDH layers. This distance expansion has been ascribed to the migration of Zn II from octahedral layers to tetrahedral sites in the interlayer space, nucleating the nano-ZnO or nano-ZnM2O4 (M = Al or Fe) amorphous prenuclei. The transformation of these nano-ZnO clusters toward ZnO crystallites proceeds through an agglomeration process occurring before the complete loss of layer stacking for Zn2Al(OH)6· nH2O and Zn2Al0.75Fe0.25(OH) 6·nH2O. For ZnCuAl(OH)6·nH 2O and ZnCuAl0.5Fe0.5(OH)6· nH2O, a cooperative effect between the formation of nano-CuO and nano-ZnAl2O4 amorphous clusters facilitates the topochemical transformation of LDH to spinel due to the contribution of octahedral CuII vacancy to ZnII diffusion. © 2013 American Chemical Society.
Resumo:
Picosecond transient absorption (TA) and time-resolved infrared (TRIR) measurements of rac-[Cr(phen)2(dppz)]3+ (1) intercalated into double-stranded guanine-containing DNA reveal that the excited state is very rapidly quenched. As no evidence was found for the transient electron transfer products, it is proposed that the back electron transfer reaction must be even faster (<3 ps).
Resumo:
Perfluoro substituted organic compounds have attracted attention owing to their unique structure and reactivity induced by the perfluoro effect. Fluoranil, a perfluoro derivative of p-benzoquinone, is the subject of this paper. Although the perfluoro effect in the ground state seems to have been well understood there is no information available about such effects on the excited state. Here, the time-resolved resonance Raman spectra of the triplet excited state of fluoranil are reported along with the Raman excitation profiles (REPs) of the various vibrational modes. The vibrational spectral analyses have been carried out by analogy with the fluoranil ground state, triplet benzoquinone, and triplet chloranil vibrational spectral assignments. Also, the assignments are further supported by the calculated frequencies using ab initio theoretical methods. It is observed that for fluoranil in the triplet excited state, due to the perfluoro effect, the structure is considerably less distorted than benzoquinone and also the electron delocalization in the pi* antibonding orbital is less than that of triplet excited state of benzoquinone.
Resumo:
The study of reaction mechanisms involves systematic investigations of the correlation between structure, reactivity, and time. The challenge is to be able to observe the chemical changes undergone by reactants as they change into products via one or several intermediates such as electronic excited states (singlet and triplet), radicals, radical ions, carbocations, carbanions, carbenes, nitrenes, nitrinium ions, etc. The vast array of intermediates and timescales means there is no single ``do-it-all'' technique. The simultaneous advances in contemporary time-resolved Raman spectroscopic techniques and computational methods have done much towards visualizing molecular fingerprint snapshots of the reactive intermediates in the microsecond to femtosecond time domain. Raman spectroscopy and its sensitive counterpart resonance Raman spectroscopy have been well proven as means for determining molecular structure, chemical bonding, reactivity, and dynamics of short-lived intermediates in solution phase and are advantageous in comparison to commonly used time-resolved absorption and emission spectroscopy. Today time-resolved Raman spectroscopy is a mature technique; its development owes much to the advent of pulsed tunable lasers, highly efficient spectrometers, and high speed, highly sensitive multichannel detectors able to collect a complete spectrum. This review article will provide a brief chronological development of the experimental setup and demonstrate how experimentalists have conquered numerous challenges to obtain background-free (removing fluorescence), intense, and highly spectrally resolved Raman spectra in the nanosecond to microsecond (ns-mu s) and picosecond (ps) time domains and, perhaps surprisingly, laid the foundations for new techniques such as spatially offset Raman spectroscopy.
Resumo:
Background: A time-resolved fluorescence immunoassay (TRFIA), based on anti-microcystin-LR (MCLR) monoclonal antibodies (MAbs) and europium-labeled antimouse IgG conjugate, was first developed for microcystin detection. Methods: Anti-MCLR MAbs were prepared by a standard method, and the attained MAbs showed a good cross reactivity with MCLR, MCRR and MCYR. The TRFIA was performed in an indirect competitive mode. The detection method of TRFIA was compared with indirect competitive enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC). Results: The TRFIA exhibited a typical sigmoidal response for MCLR at concentrations of 0.005-50 ng/ml, with a wide quantitative range between 0.01 and 10 ng/ml, indicating the broadest detective range and the most sensitive of all the methods for microcystins (MCs) detection. Additionally, the TRFIA maintained good reliability through its quantitative range, as evidenced by low coefficients of variation (1.6-12.2%). The toxin data of algal samples assayed from TRFIA were in the same range as those with ELISA and HPLC, implying that the method was reliable and practical for the detection of MCs. Conclusions: The TRFIA may offer a valuable alternative or a substitute for conventional ELISA for microcystin detection. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Silica-based functionalized terbium fluorescent nanoparticles were prepared, characterized and developed as a fluorescence probe for antibody labeling and time-resolved fluoroimmunoassay. The nanoparticles were prepared in a water-in-oil (W/O) microemulsion containing a strongly fluorescent Tb3+ chelate. N,N.N-1,N-1-12,6-bis(3'-aminomethyl-1'-pyrazolyl)phenylpyridine] tetrakis(acetate)-Tb3+ (BPTA-Tb3+), Triton X-100, octanol, and cyclohexane by controlling copolymerization of tetraethyl orthosilicate (TEOS) and 3-[2-(2- aminoethylamino)-ethylamino]propyl-trimethoxysilane (AEPS) with ammonia water. The characterizations by transmission electron microscopy and fluorometric quantum methods show that the nanoparticles are spherical and uniform in size, 45 +/- 3 nm in diameter, strongly fluorescent with fluorescence yield of 10% and a long fluorescence lifetime of 2.0 ms. The amino groups directly introduced to the nanoparticle's surface by using AEPS in the preparation made the surface modification and bioconjugation of the nanoparticles easier. The nanoparticle-labeled anti-human alpha-fetoprotein antibody was prepared and used for time-resolved fluoroimmunoassay of (x-fetoprotein (AFP) in human serum samples. The assay response is linear from 0.10 ng ml(-1) to about 100 ng ml(-1) with the detection limit of 0.10 ng ml(-1). The coefficient variations (CVs) of the method are less than 9.0%. and the recoveries are in the range of 84-98% for human serum sample measurements. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This article presents our most recent advances in synchronous fluorescence (SF) methodology for biomedical diagnostics. The SF method is characterized by simultaneously scanning both the excitation and emission wavelengths while keeping a constant wavelength interval between them. Compared to conventional fluorescence spectroscopy, the SF method simplifies the emission spectrum while enabling greater selectivity, and has been successfully used to detect subtle differences in the fluorescence emission signatures of biochemical species in cells and tissues. The SF method can be used in imaging to analyze dysplastic cells in vitro and tissue in vivo. Based on the SF method, here we demonstrate the feasibility of a time-resolved synchronous fluorescence (TRSF) method, which incorporates the intrinsic fluorescent decay characteristics of the fluorophores. Our prototype TRSF system has clearly shown its advantage in spectro-temporal separation of the fluorophores that were otherwise difficult to spectrally separate in SF spectroscopy. We envision that our previously-tested SF imaging and the newly-developed TRSF methods will combine their proven diagnostic potentials in cancer diagnosis to further improve the efficacy of SF-based biomedical diagnostics.
Resumo:
Gas temperature is of major importance in plasma based surface treatment, since the surface processes are strongly temperature sensitive. The spatial distribution of reactive species responsible for surface modification is also influenced by the gas temperature. Industrial applications of RF plasma reactors require a high degree of homogeneity of the plasma in contact with the substrate. Reliable measurements of spatially resolved gas temperatures are, therefore, of great importance. The gas temperature can be obtained, e.g. by optical emission spectroscopy (OES). Common methods of OES to obtain gas temperatures from analysis of rotational distributions in excited states do not include the population dynamics influenced by cascading processes from higher electronic states. A model was developed to evaluate this effect on the apparent rotational temperature that is observed. Phase resolved OES confirmed the validity of this model. It was found that cascading leads to higher apparent temperatures, but the deviation (similar or equal to 25 K) is relatively small and can be ignored in most cases. This analysis is applied to investigate axially and radially resolved temperature profiles in an inductively coupled hydrogen RF discharge.
Resumo:
The first report of time-resolved resonance Raman (TR(3)) scattering in a supercritical fluid is presented. TR(3) spectra of the lowest triplet excited state (T-1) of anthracene in supercritical (SC) CO2 have been obtained over the pressure range 90-500 bar. These data have been complemented by conventional flash photolysis measurements of the excited state lifetime, transient absorbance difference, and fluorescence spectra over a similar pressure range. The spectroscopic data show systematic changes with increasing pressure; the Delta A spectra of the TI state recorded at two different temperatures display a red shift with increasing fluid pressure, which is in agreement with earlier work carried out over a smaller range of pressures. Similar shifts in the fluorescence are also observed. The vibrational frequencies of the T-1 state of anthracene are found to be relatively insensitive to applied pressure; indeed, the transient bands are readily identified by comparison with resonance Raman (RR) spectra of the T-1 state in cyclohexane solution. Small but well-defined shifts to lower cm(-1) with increasing pressure are observed in some of the vibrational bands of SC COE. The most marked change in the excited state Raman spectra is that the intensity of the T-1 anthracene features, relative to those of CO2, increases with applied pressure. The information which each of the above spectroscopic methods gives on the question of how pressure changes affect the structure and local environment of the excited state probe molecule in the SCF is discussed. Possible explanations for the observed increase in RR band intensities in terms of increased resonance Raman enhancement arising from the spectral shifts and/or the increased solubility of anthracene in CO2 with increasing pressure are also considered.
Resumo:
Haptoglobin (Hp) is recognised as a major acute phase protein in the bovidae and its presence in serum is used as an indicator of inflammation. A mouse monoclonal antibody (1D9) specific for bovine Hp was labelled with a lanthanide (Eu) chelate and used to develop a competitive immunoassay. This competitive immunoassay allowed direct measurement of Hp in serum and was validated for intra- and interassay coefficients of variation (below 8%). Cross-reactivity with other serum proteins was measured (less than 0.1%) and limits of detection for Hp in serum were established for adult male (0.344 mu g/ml) and adult female cattle (1.589 mu g/ml). The immunoassay was compared with an established haptoglobin-haemoglobin binding assay.
Resumo:
Comparisons between experimentally measured time-dependent electron energy distribution functions and optical emission intensities are reported for low-frequency (100 and 400 kHz) radio-frequency driven discharges in argon. The electron energy distribution functions were measured with a time-resolved Langmuir probe system. Time-resolved optical emissions of argon resonance lines at 687.1 and 750.4 nm were determined by photon-counting methods. Known ground-state and metastable-state excitation cross sections were used along with the measured electron energy distribution functions to calculate the time dependence of the optical emission intensity. It was found that a calculation using only the ground-state cross sections gave the best agreement with the time dependence of the measured optical emission. Time-dependent electron density, electron temperature, and plasma potential measurements are also reported.
Resumo:
The rotavirus (RV) inner capsid protein VP6 is widely used to evaluate immune response during natural infection and in vaccine studies. Recombinant VP6 from the most prevalent circulating rotavirus strains in each subgroup (SG) identified in a birth cohort of children in southern India [SGII (G1P[8]) and SGI (G10P[11])] were produced. The purified proteins were used to measure VP6-specific antibodies in a Dissociation-Enhanced Lanthanide Fluorometric Immunoassay (DELFIA). The ability of the assay to detect a =2 fold rise in IgG level in a panel of serum samples from a longitudinal study was compared to a gold standard virus-capture ELISA. A strong association was observed between the assays (p