747 resultados para Sensor placement
Resumo:
This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.
Resumo:
Dynamic thermal management techniques require a collection of on-chip thermal sensors that imply a significant area and power overhead. Finding the optimum number of temperature monitors and their location on the chip surface to optimize accuracy is an NP-hard problem. In this work we improve the modeling of the problem by including area, power and networking constraints along with the consideration of three inaccuracy terms: spatial errors, sampling rate errors and monitor-inherent errors. The problem is solved by the simulated annealing algorithm. We apply the algorithm to a test case employing three different types of monitors to highlight the importance of the different metrics. Finally we present a case study of the Alpha 21364 processor under two different constraint scenarios.
Resumo:
Ultrasound wave velocity was measured in 30 pieces of Spanish Scots pine (Pinus sylvestris L.), 90 x 140 mm in cross-section and 4 m long. Five different sensor placement arrangements were used: end to end (V0), face to opposite face, edge to opposite edge, face to same face and edge to same edge. The pieces were successively shortened to 3, 2 and 1 m, in order to obtain these velocities and their ratios to reference value V0 for different lengths and angles with respect to the piece axis for the crossed measurements. The velocity obtained in crossed measurements is lower than V0. A correction coefficient for crossed velocities is proposed, depending on the angle, to adjust them to the V0 benchmark. The velocities measured on a surface, are also lower than V0, and their ratio with respect to V0 is close to 0.97 for distances equal to or greater than 18 times the depth of the beam.
Resumo:
Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.
Resumo:
To determine the effect of sensor placement on the performance of a disease-warning system for sooty blotch and flyspeck (SBFS), we measured leaf wetness duration (LWD) at 12 canopy positions in apple trees, then simulated operation of the disease-warning system using LWD measurements from different parts of the canopy. LWD sensors were placed in four trees within one Iowa orchard during two growing seasons, and in one tree in each of four orchards during a single growing season. The LWD measurements revealed substantial heterogeneity among sensor locations. In all data sets, the upper, eastern portion of the canopy had the longest mean daily LWD, and was the first site to form dew and the last to dry. The lower, western portion of the canopy averaged about 3 It less LWD per day than the top of the canopy, and was the last zone where dew formed and the first to dry off. On about 25% of nights when dew occurred in the top of the canopy, no dew formed in the lower, western canopy. Intracanopy variability of LWD was more pronounced when dew was the sole source of wetness than on days when rainfall occurred. Daily LWD in the upper, eastern portion of the canopy was slightly less than reference measurements made at a 0.7-m height over turfgrass located near the orchard. When LWD measurements from several canopy positions were input to the SBFS warning system, timing of occurrence of a fungicide-spray threshold varied by as much as 30 days among canopy positions. Under Iowa conditions, placement of an LWD sensor at an unobstructed site over turfgrass was a fairly accurate surrogate for the wettest part of the canopy. Therefore, such an extra-canopy LWD sensor might be substituted for a within-canopy sensor to enhance operational reliability of the SBFS warning system.
Resumo:
Objectives: Advances in surface electromyography (sEMG) techniques provide a clear indication that refinement of electrode location relative to innervation zones (IZ) is required in order to optimise the accuracy, relevance and repeatability of the sEMG signals. The aim of this study was to identify the IZ for the sternocleidomastoid and anterior scalene muscles to provide guidelines for electrode positioning for future clinical and research applications. Methods: Eleven volunteer subjects participated in this study. Myoelectric signals were detected from the sternal and clavicular heads of the stemocleidomastoid and the anterior scalene muscles bilaterally using a linear array of 8 electrodes during isometric cervical flexion contractions. The signals were reviewed and the IZ(s) were identified, marked on the subjects' skin and measurements were obtained relative to selected anatomical landmarks. Results: The position of the IZ lay consistently around the mid-point or in the superior portion of the muscles studied. Conclusions: Results suggest that electrodes should be positioned over the lower portion of the muscle and not the mid-point, which has been commonly used in previous studies. Recommendations for sensor placement on these muscles should assist investigators and clinicians to ensure improved validity in future sEMG applications. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
New business and technology platforms are required to sustainably manage urban water resources [1,2]. However, any proposed solutions must be cognisant of security, privacy and other factors that may inhibit adoption and hence impact. The FP7 WISDOM project (funded by the European Commission - GA 619795) aims to achieve a step change in water and energy savings via the integration of innovative Information and Communication Technologies (ICT) frameworks to optimize water distribution networks and to enable change in consumer behavior through innovative demand management and adaptive pricing schemes [1,2,3]. The WISDOM concept centres on the integration of water distribution, sensor monitoring and communication systems coupled with semantic modelling (using ontologies, potentially connected to BIM, to serve as intelligent linkages throughout the entire framework) and control capabilities to provide for near real-time management of urban water resources. Fundamental to this framework are the needs and operational requirements of users and stakeholders at domestic, corporate and city levels and this requires the interoperability of a number of demand and operational models, fed with data from diverse sources such as sensor networks and crowsourced information. This has implications regarding the provenance and trustworthiness of such data and how it can be used in not only the understanding of system and user behaviours, but more importantly in the real-time control of such systems. Adaptive and intelligent analytics will be used to produce decision support systems that will drive the ability to increase the variability of both supply and consumption [3]. This in turn paves the way for adaptive pricing incentives and a greater understanding of the water-energy nexus. This integration is complex and uncertain yet being typical of a cyber-physical system, and its relevance transcends the water resource management domain. The WISDOM framework will be modeled and simulated with initial testing at an experimental facility in France (AQUASIM – a full-scale test-bed facility to study sustainable water management), then deployed and evaluated in in two pilots in Cardiff (UK) and La Spezia (Italy). These demonstrators will evaluate the integrated concept providing insight for wider adoption.
Resumo:
The dataset contains measurements of river stage and discharge for one sites along the Akuliarusiarsuup Kuua River's northern tributary, with 30 minute temporal resolution between June 2008 and August 2013 This river is a tributary to the Watson River discharging into Kangerlussuaq Fjord by the town of Kangerlussuaq, Southwest Greenland. Additional data of water temperature, air pressure are also provided. Compared to version 1.0 of the dataset, this dataset used a total of 36 in situ discharge observations collected between 2008 and 2012 to construct the rating curve. Furthermore, data of Station AK-004-001 between 2010-09-06T11:30 to 2010-09-07T13:30 have been removed from version 2.0 because these values were likely caused by backflow when a jokulhlaup from a large glacier dammed lake caused increased water levels in the downstreams lake. Thus, data measured at AK-004-001 between 2010-09-06T11:30 to 2010-09-07T13:30 are not representative for the AK-004 catchment.
Resumo:
Electric vehicles (EVs) and hybrid electric vehicles (HEVs) can reduce greenhouse gas emissions while switched reluctance motor (SRM) is one of the promising motor for such applications. This paper presents a novel SRM fault-diagnosis and fault-tolerance operation solution. Based on the traditional asymmetric half-bridge topology for the SRM driving, the central tapped winding of the SRM in modular half-bridge configuration are introduced to provide fault-diagnosis and fault-tolerance functions, which are set idle in normal conditions. The fault diagnosis can be achieved by detecting the characteristic of the excitation and demagnetization currents. An SRM fault-tolerance operation strategy is also realized by the proposed topology, which compensates for the missing phase torque under the open-circuit fault, and reduces the unbalanced phase current under the short-circuit fault due to the uncontrolled faulty phase. Furthermore, the current sensor placement strategy is also discussed to give two placement methods for low cost or modular structure. Simulation results in MATLAB/Simulink and experiments on a 750-W SRM validate the effectiveness of the proposed strategy, which may have significant implications and improve the reliability of EVs/HEVs.
Resumo:
The purpose of this research is design considerations for environmental monitoring platforms for the detection of hazardous materials using System-on-a-Chip (SoC) design. Design considerations focus on improving key areas such as: (1) sampling methodology; (2) context awareness; and (3) sensor placement. These design considerations for environmental monitoring platforms using wireless sensor networks (WSN) is applied to the detection of methylmercury (MeHg) and environmental parameters affecting its formation (methylation) and deformation (demethylation). ^ The sampling methodology investigates a proof-of-concept for the monitoring of MeHg using three primary components: (1) chemical derivatization; (2) preconcentration using the purge-and-trap (P&T) method; and (3) sensing using Quartz Crystal Microbalance (QCM) sensors. This study focuses on the measurement of inorganic mercury (Hg) (e.g., Hg2+) and applies lessons learned to organic Hg (e.g., MeHg) detection. ^ Context awareness of a WSN and sampling strategies is enhanced by using spatial analysis techniques, namely geostatistical analysis (i.e., classical variography and ordinary point kriging), to help predict the phenomena of interest in unmonitored locations (i.e., locations without sensors). This aids in making more informed decisions on control of the WSN (e.g., communications strategy, power management, resource allocation, sampling rate and strategy, etc.). This methodology improves the precision of controllability by adding potentially significant information of unmonitored locations.^ There are two types of sensors that are investigated in this study for near-optimal placement in a WSN: (1) environmental (e.g., humidity, moisture, temperature, etc.) and (2) visual (e.g., camera) sensors. The near-optimal placement of environmental sensors is found utilizing a strategy which minimizes the variance of spatial analysis based on randomly chosen points representing the sensor locations. Spatial analysis is employed using geostatistical analysis and optimization occurs with Monte Carlo analysis. Visual sensor placement is accomplished for omnidirectional cameras operating in a WSN using an optimal placement metric (OPM) which is calculated for each grid point based on line-of-site (LOS) in a defined number of directions where known obstacles are taken into consideration. Optimal areas of camera placement are determined based on areas generating the largest OPMs. Statistical analysis is examined by using Monte Carlo analysis with varying number of obstacles and cameras in a defined space. ^
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
In this work a system of autonomous agents engaged in cyclic pursuit (under constant bearing (CB) strategy) is considered, for which one informed agent (the leader) also senses and responds to a stationary beacon. Building on the framework proposed in a previous work on beacon-referenced cyclic pursuit, necessary and suffi- cient conditions for the existence of circling equilibria in a system with one informed agent are derived, with discussion of stability and performance. In a physical testbed, the leader (robot) is equipped with a sound sensing apparatus composed of a real time embedded system, estimating direction of arrival of sound by an Interaural Level and Phase Difference Algorithm, using empirically determined phase and level signatures, and breaking front-back ambiguity with appropriate sensor placement. Furthermore a simple framework for implementing and evaluating the performance of control laws with the Robot Operating System (ROS) is proposed, demonstrated, and discussed.
Resumo:
Smart material technology has become an area of increasing interest for the development of lighter and stronger structures that are able to incorporate actuator and sensor capabilities for collocated control. In the design of actively controlled structures, the determination of the actuator locations and the controller gains is a very important issue. For that purpose, smart material modeling, modal analysis methods, and control and optimization techniques are the most important ingredients to be taken into account. The optimization problem to be solved in this context presents two interdependent aspects. The first is related to the discrete optimal actuator location selection problem, which is solved in this paper using genetic algorithms. The second is represented by a continuous variable optimization problem, through which the control gains are determined using classical techniques. A cantilever Euler-Bernoulli beam is used to illustrate the presented methodology.