958 resultados para SPECULAR MICROSCOPY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Both healthy eyes of 10 six-year-old male and female mongrel dogs were studied. With a contact specular microscope the corneal endothelium was examined. Endothelial cells were analyzed in the central and peripheral cornea. Morphological analysis with regard to polymegathism and pleomorphism was performed. Three images of each region with at least 100 cells were obtained. The analysis showed that polygonal cells formed a mosaic-like pattern uniform in size and shape. The predominant number of cells was hexagonal. The polymegathism index was 0.22. The study demonstrates that the morphology of the normal corneal endothelial cells of dogs is similar to that found in the human cornea.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram estudados 20 olhos de 10 cães sem raça definida, machos e fêmeas com 6 anos de idade. A morfologia das células do endotélio da córnea foi analisada utilizando-se microscópio especular de contato. Foram estudadas as regiões central e periférica da córnea. de cada região da córnea foram realizadas três micrografias. de cada micrografia foram analisadas no mínimo 100 células endoteliais. Foram obtidos os valores do polimegatismo e pleomorfismo. O endotélio corneano de cães caracterizou-se por uma monocamada de células poligonais uniformes em tamanho e forma. A forma predominante das células endoteliais foi hexagonal. O índice de polimegatismo foi 0.22. Este estudo demonstrou que a morfologia das células do endotélio da córnea de cães é semelhante à observada em humanos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of age on endothelial morphology and morphometry in cats. The corneal endothelium was studied using a contact specular microscope. A total of 18 cats (Felis catus Linnaeus, 1758) were evaluated in this study. The subjects were divided into three groups of six cats each in function of age: G1 (1 to 3 months old), G2 (5 to 12 months old), and G3 (24 to 40 months old). The examination presented data as endothelial cell density (ECD), average cell area, corneal thickness, polymegathism, and pleomorphism. Results revealed ECD decrease in corneas of normal cats with age, as well as a corresponding increase in endothelial cell area and pleomorphism. The present work suggests that the endothelial parameters evaluated change with advancing age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate and correlate intraocular pressure (IOP), endothelial cell density (CD), and hexagonality (HEX), and the aqueous humor prostaglandin E-2 (PGE(2)) concentration in dogs with mature (MG, n = 8) and hypermature (HG, n = 8) cataracts. Eight laboratory beagles with no ocular abnormalities were included as a control group (CG). The IOP was measured using a digital applanation tonometer. Noncontact specular microscopy was used to evaluate CD and HEX. Samples of aqueous humor were used to determine prostaglandin E-2 concentration using enzyme-linked immunoassay. Data were compared by ANOVA and Bonferroni's multiple comparison test, and possible correlations among the PGE(2) aqueous concentration and corneal endothelium cell parameters were assessed by Person's test (P < 0.05). Average values of IOP (P = 0.45) and CD (P = 0.39) were not significantly different between MG, HM, and CG. Average values of HEX were lower, and PGE(2) concentration was increased in the MG and HG in comparison with CG (P < 0.05); however, such parameters did not change significantly between MG and HG (P > 0.05). PGE(2) values did not correlate with IOP, CD, and HEX in any group (P > 0.05). Although there were a small number of dogs studied, our results demonstrated that cataract progression from mature to hypermature did not have a significant change in PGE(2) aqueous concentration, IOP, corneal endothelial cell count, or morphology. In addition, PGE(2) concentration was not correlated with parameters of the corneal endothelium or IOP in dogs with mature or hypermature cataracts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background/aims To compare two intraocular irrigating solutions, Balanced Salt Solution Plus (BSS Plus) versus Lactated Ringer`s (Ringer), for the preservation of corneal integrity after phacoemulsification. Methods 110 patients undergoing phacoemulsification were randomised to either BSS Plus (n = 55) or Ringer (n = 55) as the irrigating solution. Patients were examined at baseline and at 1, 8, 15, 30 and 60 days postoperatively. Evaluations included specular microscopy to evaluate endothelial cell density (ECD) and endothelial cell size variability (CV), and corneal pachymetry for central corneal thickness (CCT) measurement. Results Groups were well balanced regarding baseline ECD, CV and CCT (p>0.05). There was no statistically significant difference between ECD reduction in group BSS Plus 13.1 +/- 2.0% and Ringer 9.2 +/- 1.9% (p<0.05) at day 60 or in any study visit. There was no statistically significant difference between CV increase in group BSS Plus 23.0 +/- 3.0% and Ringer 20.2 +/- 4.0% (p<0.05) at day 60 or in any study visit. CCT was significantly increased (p<0.05) at 1, 8, 15 and 30 days postoperatively, returning to baseline at 60 days in both groups. There was no significant difference in CCT increase in both groups at any visit. Interestingly, there were statistically significant correlations between ECD loss and phacoemulsification time (p<0.0001) and ECD loss and irrigation solution volume (p<0.0001) in the Ringer group, but not in the BSS Plus group. Conclusions Ringers solution was similar to BSS Plus for corneal preservation in atraumatic cataract surgery. However, our study demonstrates that there is a trend towards lower postoperative endothelial cell density for surgeries with longer phacoemulsification time and higher irrigation volumes if Ringer is used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To make surgeons performing nonpenetrating filtering surgery aware of an unusual complication namely Descemet membrane detachment. METHODS: We retrospectively reviewed nine eyes of nine patients seen in our hospital with Descemet membrane detachment occurring after nonpenetrating filtering surgery from January 1994 to December 2000. RESULTS: Both planar and nonplanar detachments were reported. Neither scrolls nor tears in the Descemet membrane were observed in any patient. After viscocanalostomy (four patients), the detachment was generally noticed shortly after the procedure and the cornea maintained its clarity. After deep sclerectomy with a collagen implant (five patients), it developed weeks to months postoperatively with adjacent corneal edema. Four patients had descemetopexy. None required more than one procedure. However, at the last visit, two detachments persisted although they had diminished in size: one after viscocanalostomy and conservative treatment and one after descemetopexy after deep sclerectomy with a collagen implant. To date otherwise, no signs of significant corneal damage could be observed clinically nor by specular microscopy and pachymetry. CONCLUSIONS: The diagnosis of Descemet membrane detachment can be easily overlooked or misdiagnosed. The clinical presentation, clinical course, and pathogenesis depend on the type of nonpenetrating filtering surgery performed. Ophthalmologists should be aware of this unusual complication, which is likely to be more common after nonpenetrating filtering surgery than after trabeculectomy. A period of observation before attempting descemetopexy is recommended.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O endotélio corneal é uma monocamada de células poligonais. A integridade e saúde dessa camada são essenciais para a manutenção da transparência corneal normal. Este estudo reportou pela primeira vez, de forma detalhada, a morfologia ultra-estrutural e a morfometria do endotélio corneal de suínos adultos mestiços à microscopia eletrônica de varredura (MEV). A superfície endothelial corneal apresentou um padrão regular de células poligonais, com predomínio da forma hexagonal e de bordas celulares nítidas. O núcleo foi observado como protuberância arredondada no centro da célula. Também foram observados os cílios (2-4) em apenas algumas células da região periférica da córnea, as aberturas das vesículas pinocitóticas na proximidade dos cílios, as microvilosidades, as varas da borda e as bordas celulares em formato de zigzag. A área celular média foi significativamente maior (P<0,05) no centro da córnea do que na periferia, com um coeficiente de variação menor no centro da córnea. A densidade celular média foi significativamente maior na periferia (P<0,05) e 43,9% maior que os dados reportados por outros autores na microscopia especular, o que demonstra o efeito da retração celular durante o processamento das amostras. O valor médio do número de lados das células (pleomorfismo) foi de 5,9, o que evidencia um predomínio do formato hexagonal. A percentagem de células hexagonais foi significativamente maior no centro (P<0,001). Os parâmetros obtidos nesta pesquisa servirão de base para estudos futuros sobre o efeito de medicamentos, cirurgias intracamerulares ou soluções para armazenamento de córneas para transplantes no endotélio corneal do suíno.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3% e sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2%. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to examine the endothelial surface and to perform a morphometric analysis of the corneal endothelial cells in normal eyes of dogs using specular microscopy. Morphometric analysis with regard mean cell area and cell density was performed. Both eyes of ten mixed-breed, males and females, with 6 years of age, weighing about 15 kg euthanatized for reasons unrelated to this study were evaluated. Eyes were examined to determine that they did not have visible ocular disease and transported to the laboratory in moist chamber. Using a contact specular microscope the corneal endothelium was examined. Three images of the central corneal endothelium of each eye were obtained. The mean cell area and the cell density of the corneal endothelial cells were obtained using software for corneal endothelium analysis and density measurement. The mean cell area was 395 ± 36 μm 2 and the endothelial cell density was 2555 ± 240 cells/mm2. The present work demonstrates that the normal corneal endothelium of dog is similar to those described in human.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV