989 resultados para Power profile
Resumo:
Managers are central to any fuction in a complex and developed society. Their talents are reckoned to be cardinal in developed economies and a basic yearning of all developing economies.In order to survive and produce results in a turbulent and transient environment, the task is to understand the nature of factors contributing to managerial effectiveness. This study is an attempt towards this core issue of the present from a different perspective. This study tries to focus attention on a group of managers functioning in the field of banking, a core sector in the country's economy. The gamut of economic activities in Kerala being predominantly service-oriented, importance of commercial banking is almost indisputable. Though economists would argue that the disproportionate development of service sector is anomalous when viewed against the hazy scenarios in the primary and secondary sectors of the state’s economy, the extent and pace of growth in the banking sector has had its dole meted out by ambitious and productive managers fiinctioning in the field. Researcher’s attempt here is to thresh the grain and chaff among bank managers in terms of their effectiveness and to account for the variations in the light of their ability to affect the thoughts and actions of their subordinates. To put it succinctly, the attempt herein is to explain the effectiveness of bank managers in the light of their ‘Power Profile’ taken to be comprising Power Differentials, Power Bases, their Visibility and Credibility in the organisation and, the Power Styles typically used by them for influencing subordinates.
Resumo:
Iterative multiuser joint decoding based on exact Belief Propagation (BP) is analyzed in the large system limit by means of the replica method. It is shown that performance can be improved by appropriate power assignment to the users. The optimum power assignment can be found by linear programming in most technically relevant cases. The performance of BP iterative multiuser joint decoding is compared to suboptimum approximations based on Interference Cancellation (IC). While IC receivers show a significant loss for equal-power users, they yield performance close to BP under optimum power assignment.
Resumo:
This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.
Resumo:
We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.
Resumo:
We report an efficient power tapping device working in near infra-red (800 nm) wavelength region based on UV-in- scribed 45° tilted fiber grating (45°-TFG) structure. Five 45°-TFGs were UV-inscribed in hydrogenated PS750 fiber using a custom-designed phase mask with different grating lengths of 3 mm, 5 mm, 9 mm, 12 mm and 15 mm, showing polarization dependent losses (PDLs) of 1 dB, 3 dB, 7 dB, 10 dB and 13 dB, respectively. The power side-tapping efficiency is clearly depending on the grating strength. It has been identified that the power tapping efficiency increases with the grating strength and deceases along the grating length. The side-tapped power profile has also been examined in azimuthal direction, showing a near-Gaussian distribution. These experimental results clearly demonstrated that 45°- TFGs may be used as in-fiber power tapping devices for applications requiring in-line signal monitoring.
Resumo:
We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.
Resumo:
La constante crisis que ha atravesado la república Islámica de Afganistán, durante más de dos décadas, tiene sus cimientos en el choque entre las diferentes etnias y grupos religiosos que conforman la sociedad afgana, los cuales han conformado una larga lucha por hacerse al poder y a la dirigencia de esta nación. Pashtunes, tayikos y hazaras, son parte de la composición étnica, mientras que sunitas y chiítas por parte del Islám, y minorías budistas, hinduistas y sijs, conforman la variedad de religiones que se encuentran en este país. La mayoría de población es pashtun y sunnita, y por lo mismo la mayoría de gobiernos que han encabezado la nación afgana han sido igualmente de esta etnia y religión. A pesar de ello, se encuentran hasta hoy diferencias entre este mismo grupo que se expresan en cuán estricta debe ser regida la vida de un musulmán por el Corán y la Sharia.
Resumo:
This paper presents evaluations among the most usual maximum power point tracking (MPPT) techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic (PV) panel [tracking factor (TF)] in relation to the available power, PV voltage ripple, dynamic response, and use of sensors. Using MatLab/Simulink and dSPACE platforms, a digitally controlled boost dc-dc converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented for conventional MPPT algorithms and improved MPPT algorithms named IC based on proportional-integral (PI) and perturb and observe based on PI. Moreover, the dynamic response and the TF are also evaluated using a user-friendly interface, which is capable of online program power profiles and computes the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2012 IEEE.
Resumo:
Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.
Resumo:
En este estudio se ha realizado el diseño de un receptor de una central de Torre Central de energía solar para generación directa de vapor, mediante el uso de métodos numéricos, con un perfil de potencia incidente variable longitudinal y transversalmente. Para ello se ha dividido la geometría del receptor según el método de diferencias finitas, y se ha procedido a resolver las ecuaciones del balance de energía. Una vez resuelto el sistema de ecuaciones se dispone de la distribución de temperaturas en el receptor y se puede proceder a analizar los resultados así como a calcular otros datos de interés. ABSTRACT In this study it has been made a Central Receiver Solar Thermal Power Plant’s Receiver design for direct steam production, by using numerical methods, with a variable longitudinally and transversely income solar power profile. With this propose, the receiver’s geometry has been divided using the finite difference method, and the energy balance equations have been solved. Once the equations system has been solved, the receiver´s temperature distribution is known, and you can analyze the results as well as calculate other interesting data.
Resumo:
Ocean energy is a promising resource for renewable electricity generation that presents many advantages, such as being more predictable than wind energy, but also some disadvantages such as large and slow amplitude variations in the generated power. This paper presents a hardware-in-the-loop prototype that allows the study of the electric power profile generated by a wave power plant based on the oscillating water column (OWC) principle. In particular, it facilitates the development of new solutions to improve the intermittent profile of the power fed into the grid or the test of the OWC behavior when facing a voltage dip. Also, to obtain a more realistic model behavior, statistical models of real waves have been implemented.
Resumo:
Digital back-propagation (DBP) has recently been proposed for the comprehensive compensation of channel nonlinearities in optical communication systems. While DBP is attractive for its flexibility and performance, it poses significant challenges in terms of computational complexity. Alternatively, phase conjugation or spectral inversion has previously been employed to mitigate nonlinear fibre impairments. Though spectral inversion is relatively straightforward to implement in optical or electrical domain, it requires precise positioning and symmetrised link power profile in order to avail the full benefit. In this paper, we directly compare ideal and low-precision single-channel DBP with single-channel spectral-inversion both with and without symmetry correction via dispersive chirping. We demonstrate that for all the dispersion maps studied, spectral inversion approaches the performance of ideal DBP with 40 steps per span and exceeds the performance of electronic dispersion compensation by ~3.5 dB in Q-factor, enabling up to 96% reduction in complexity in terms of required DBP stages, relative to low precision one step per span based DBP. For maps where quasi-phase matching is a significant issue, spectral inversion significantly outperforms ideal DBP by ~3 dB.
Resumo:
We propose a modification of the nonlinear digital signal processing technique based on the nonlinear inverse synthesis for the systems with distributed Raman amplification. The proposed path-average approach offers 3 dB performance gain, regardless of the signal power profile.
Resumo:
Plan and profile of discharge tunnel along Niagara River. The horizontal scale is 1 inch = 100 feet, the vertical scale is 1 inch = 40 feet. The drawing is dated November 7, 1902.
Resumo:
Hadron therapy is a promising technique to treat deep-seated tumors. For an accurate treatment planning, the energy deposition in the soft and hard human tissue must be well known. Water has been usually employed as a phantom of soft tissues, but other biomaterials, such as hydroxyapatite (HAp), used as bone substitute, are also relevant as a phantom for hard tissues. The stopping power of HAp for H+ and He+ beams has been studied experimentally and theoretically. The measurements have been done using the Rutherford backscattering technique in an energy range of 450-2000 keV for H+ and of 400-5000 keV for He+ projectiles. The theoretical calculations are based in the dielectric formulation together with the MELF-GOS (Mermin Energy-Loss Function – Generalized Oscillator Strengths) method [1] to describe the target excitation spectrum. A quite good agreement between the experimental data and the theoretical results has been found. The depth dose profile of H+ and He+ ion beams in HAp has been simulated by the SEICS (Simulation of Energetic Ions and Clusters through Solids) code [2], which incorporates the electronic stopping force due to the energy loss by collisions with the target electrons, including fluctuations due to the energy-loss straggling, the multiple elastic scattering with the target nuclei, with their corresponding nuclear energy loss, and the dynamical charge-exchange processes in the projectile charge state. The energy deposition by H+ and He+ as a function of the depth are compared, at several projectile energies, for HAp and liquid water, showing important differences.