958 resultados para Legacy Software


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Many-core systems provide a great potential in application performance with the massively parallel structure. Such systems are currently being integrated into most parts of daily life from high-end server farms to desktop systems, laptops and mobile devices. Yet, these systems are facing increasing challenges such as high temperature causing physical damage, high electrical bills both for servers and individual users, unpleasant noise levels due to active cooling and unrealistic battery drainage in mobile devices; factors caused directly by poor energy efficiency. Power management has traditionally been an area of research providing hardware solutions or runtime power management in the operating system in form of frequency governors. Energy awareness in application software is currently non-existent. This means that applications are not involved in the power management decisions, nor does any interface between the applications and the runtime system to provide such facilities exist. Power management in the operating system is therefore performed purely based on indirect implications of software execution, usually referred to as the workload. It often results in over-allocation of resources, hence power waste. This thesis discusses power management strategies in many-core systems in the form of increasing application software awareness of energy efficiency. The presented approach allows meta-data descriptions in the applications and is manifested in two design recommendations: 1) Energy-aware mapping 2) Energy-aware execution which allow the applications to directly influence the power management decisions. The recommendations eliminate over-allocation of resources and increase the energy efficiency of the computing system. Both recommendations are fully supported in a provided interface in combination with a novel power management runtime system called Bricktop. The work presented in this thesis allows both new- and legacy software to execute with the most energy efficient mapping on a many-core CPU and with the most energy efficient performance level. A set of case study examples demonstrate realworld energy savings in a wide range of applications without performance degradation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper concerns the application of recent information technologies for creating a software system for numerical simulations in the domain of plasma physics and in particular metal vapor lasers. The presented work is connected with performing modernization of legacy physics software for reuse on the web and inside a Service-Oriented Architecture environment. Applied and described is the creation of Java front-ends of legacy C++ and FORTRAN codes. Then the transformation of some of the scientific components into web services, as well as the creation of a web interface to the legacy application, is presented. The use of the BPEL language for managing scientific workflows is also considered.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Тодор П. Чолаков, Димитър Й. Биров - Тази статия представя цялостен модел за автоматизиран реинженеринг на наследени системи. Тя описва в детайли процесите на превод на софтуера и на рефакторинг и степента, до която могат да се автоматизират тези процеси. По отношение на превода на код се представя модел за автоматизирано превеждане на код, съдържащ указатели и работа с адресна аритметика. Също така се дефинира рамка за процеса на реинженеринг и се набелязват възможности за по-нататъшно развитие на концепции, инструменти и алгоритми.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

MSc. Dissertation presented at Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa to obtain the Master degree in Electrical and Computer Engineering

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Käyttöjärjestelmän uuden version myötä vanhat ohjelmat eivät välttämättä toimi uudessa ympäristössä. Windows-käyttöjärjestelmässä sovellusten yhteensopivuus on aiemmin säilytetty melko hyvin. Uusimpiin Windows Vista ja Windows 7 -versioihin on tehty paljon tietoturvauudistuksia. Niistä johtuen vanhojen ohjelmien yhteensopivuutta on karsittu. Tässä työssä kuvataan automaatiojärjestelmän ohjelmakomponenttien siirtoa uuteen Windows-ympäristöön. Tavoitteena on saada tehtyä ohjeita muille automaatiojärjestelmän kehittäjille. Myös Windowsin tietoturvaominaisuuksiin tehdään katsaus, erityisesti pääsynhallintaan

Relevância:

30.00% 30.00%

Publicador:

Resumo:

More and more current software systems rely on non trivial coordination logic for combining autonomous services typically running on different platforms and often owned by different organizations. Often, however, coordination data is deeply entangled in the code and, therefore, difficult to isolate and analyse separately. COORDINSPECTOR is a software tool which combines slicing and program analysis techniques to isolate all coordination elements from the source code of an existing application. Such a reverse engineering process provides a clear view of the actually invoked services as well as of the orchestration patterns which bind them together. The tool analyses Common Intermediate Language (CIL) code, the native language of Microsoft .Net Framework. Therefore, the scope of application of COORDINSPECTOR is quite large: potentially any piece of code developed in any of the programming languages which compiles to the .Net Framework. The tool generates graphical representations of the coordination layer together and identifies the underlying business process orchestrations, rendering them as Orc specifications

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Dataflow programs are widely used. Each program is a directed graph where nodes are computations and edges indicate the flow of data. In prior work, we reverse-engineered legacy dataflow programs by deriving their optimized implementations from a simple specification graph using graph transformations called refinements and optimizations. In MDE-speak, our derivations were PIM-to-PSM mappings. In this paper, we show how extensions complement refinements, optimizations, and PIM-to-PSM derivations to make the process of reverse engineering complex legacy dataflow programs tractable. We explain how optional functionality in transformations can be encoded, thereby enabling us to encode product lines of transformations as well as product lines of dataflow programs. We describe the implementation of extensions in the ReFlO tool and present two non-trivial case studies as evidence of our work’s generality

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cloud computing, despite its success and promises, presents issues for businesses mi­grating their legacy applications to cloud. In this research legacy-to-cloud migration issues are reviewed based on literature findings and an experience report. Solutions are applied to Tieto Open Application Suite (TOAS) software development platform running on cloud infrastructure. It is observed that the migration strategy heavily affects the migration approach. For TOAS a strategy of redesigning the applications for cloud is suggested. Common migration-driven application level modifications in­clude adaptation to service-oriented architecture, load balancing, and runtime and technology changes. A cloud platform such as TOAS might introduce additional needs. Decision making on migration strategy is found to be an issue to be solved case by case. Use of assistive decision making tools is suggested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When reengineering legacy systems, it is crucial to assess if the legacy behavior has been preserved or how it changed due to the reengineering effort. Ideally if a legacy system is covered by tests, running the tests on the new version can identify potential differences or discrepancies. However, writing tests for an unknown and large system is difficult due to the lack of internal knowledge. It is especially difficult to bring the system to an appropriate state. Our solution is based on the acknowledgment that one of the few trustable piece of information available when approaching a legacy system is the running system itself. Our approach reifies the execution traces and uses logic programming to express tests on them. Thereby it eliminates the need to programatically bring the system in a particular state, and handles the test-writer a high-level abstraction mechanism to query the trace. The resulting system, called TESTLOG, was used on several real-world case studies to validate our claims.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Processor emulators are a software tool for allowing legacy computer programs to be executed on a modern processor. In the past emulators have been used in trivial applications such as maintenance of video games. Now, however, processor emulation is being applied to safety-critical control systems, including military avionics. These applications demand utmost guarantees of correctness, but no verification techniques exist for proving that an emulated system preserves the original system’s functional and timing properties. Here we show how this can be done by combining concepts previously used for reasoning about real-time program compilation, coupled with an understanding of the new and old software architectures. In particular, we show how both the old and new systems can be given a common semantics, thus allowing their behaviours to be compared directly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Half a decade has passed since the objectives and benefits of autonomic computing were stated, yet even the latest system designs and deployments exhibit only limited and isolated elements of autonomic functionality. From an autonomic computing standpoint, all computing systems – old, new or under development – are legacy systems, and will continue to be so for some time to come. In this paper, we propose a generic architecture for developing fully-fledged autonomic systems out of legacy, non-autonomic components, and we investigate how existing technologies can be used to implement this architecture.