184 resultados para IMMUNOASSAYS
Resumo:
High molecular weight mucins represent a unique challenge as tumor markers by virtue of their complex array of epitopes, The list is dominated by the high molecular weight mucins MUC1, CEA and CA125. While the currently accepted role for these tumor markers is in the prediction and detection of relapse, it is possible that their sensitivity and specificity can be improved. Although immunoassays detecting the tumor marker MUC1 are both sensitive and specific for predicting relapse in breast cancer, so far they are not in widespread use in the follow-up of this disease. Are there new combinations of conventional reagents that could improve assay sensitivity, or should we be looking for more radical changes in assay design incorporating combinatorial technology? Copyright (C) 2001 S. Karger AG, Basel.
Resumo:
OBJECTIVE Because there is discordance between different immunoassay values for serum hGH, and because clinical state may not correlate with immunoreactive hGH, we have developed an assay to accurately measure serum hGH somatogenic bioactivity. The results of this assay were compared with the Elegance two-site ELISA assay across 135 patient samples in a variety of clinical states. DESIGN The somatogenic assay was based on stable expression of hGH receptor in the murine BaF line, allowing these cells to proliferate in response to hGH. To eliminate interference by other growth factors in serum, we created a specific antagonist of the hGH receptor (similar to Trovert or Pegvisomant) which allowed us to obtain a true measure of hGH somatogenic activity by subtraction of the activity in the presence of the antagonist. The assay was carried out in microtiter plates over 24 h, with oxidation of a chromogenic tetrazolium salt (MTT) as the endpoint. PATIENTS These encompassed a number of different clinical conditions related to short stature, including idiopathic short stature, neurosecretory dysfunction and renal failure, as well as obese patients on dietary restriction and normal volunteers. MEASUREMENTS In addition to the colourimetric (MTT) response to hGH, we measured free hGH by stripping out GHBP-bound hGH using beads coupled to a monoclonal antibody to the GHBP (GH binding protein). All samples were measured in both bioassay and ELISA assay. RESULTS This bioassay was sensitive (5 mU/l or 2 mug/l) and precise, and not subject to interference by the GHBP. There was a good correlation (r = 0.95) between bioactivity and immunoactivity across clinical states. There was, however, an increased bioactivity during secretory peaks (over 25 mU/l), which has been reported previously for the Nb2 bioassay. Free hGH did not correlate with clinical state. CONCLUSIONS Because the results of the Elegance ELISA and the bioassay correlate well, even though there is greater bioactivity at higher hormone concentrations, it is evident that an appropriate immunoassay is able to act as a reliable indicator for clinical assessment. In those rare cases where bio-inactive GH exists, our bioassay should provide an appropriate means to demonstrate this.
Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen
Resumo:
Two competitive enzyme immunoassays (EIA) techniques were developed: in the first (COMP-1), test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2), test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB) as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.
Resumo:
The influence of time and temperature on the storage of an alkaline antigen of L.major-like and L.(V.) braziliensis promastigotes added or not of a proteases inhibitor (PMSF) was evaluted by means of an IgG-ELISA. Antibodies in assays using L. major-like antigen stored at -20oC for 6 monsths had a statistically lower geometric mean titer (GMT) and different 95% confidence interval limits (CL) than antigens stored otherwise, as assessed by the "t" statistic. The PMSF L. major-like antigen after storage for 6 months at a temperature of 4oC had the same GMT and 95% CL displayed at time zero as well as when storage for 4 and 6 months at -20oC. Significant diferences were not found when L.(V.) braziliensis antigens were stored at times and temperatures mentioned; the PMSF antigen stored for 2 months at -70oC resulted in a lower serum GMT and 95% CL than any other, as assessed by the "t" statistic. Antigen performance did not show any statistical difference associated to the addition of PMSF within the same species; the largest difference between antigens was that between PMSF-L. (V.) braziliensis and L. major-like without PMSF.
Resumo:
Introduction Despite the known importance of Clostridium difficile as a nosocomial pathogen, few studies regarding Clostridium difficile infection (CDI) in Brazil have been conducted. To date, the diagnostic tests that are available on the Brazilian market for the diagnosis of CDI have not been evaluated. The aim of this study was to compare the performances of four commercial methods for the diagnosis of CDI in patients from a university hospital in Brazil. Methods Three enzyme immunoassays (EIAs) and one nucleic acid amplification test (NAAT) were evaluated against a cytotoxicity assay (CTA) and toxigenic culture (TC). Stool samples from 92 patients with suspected CDI were used in this study. Results Twenty-five (27.2%) of 92 samples were positive according to the CTA, and 23 (25%) were positive according to the TC. All EIAs and the NAAT test demonstrated sensitivities between 59 and 68% and specificities greater than 91%. Conclusions All four methods exhibited low sensitivities for the diagnosis of CDI, which could lead to a large number of false-negative results, an increased risk of cross-infection to other patients, and overtreatment with empirical antibiotics.
Resumo:
This paper presents the evaluation of an enzyme immunoassay in which Mayaro virus-infected cultured cells ara used as antigen (EIA-ICC) and an IgM antibody capture ELISA (MAC-ELISA) for Mayaro serologic diagnosis using 114 human sera obtained during a Mayaro outbreak occurred in Bolivia, in 1987. Results were compared with those obtained by haemagglutination-inhibition test (HAI). MAC-ELISA was the most sensitive technique for anti-Mayaro IgM detection. MAC-ELISA was twice sensitive as IgM EIA-ICC. The data shows that MAC-ELISA is a practical and valid technique for diagnosis of recent mayaro infection. IgG-ICC showed hight sensitivity and high specificity compared to HAI. The combination of anti-Mayaro IgG and IgM EIA-ICC results presented the highest sensitivity of the study. Anti-Mayaro IgG and IgM simultaneous detection by ELISA-ICC can be used for recent infection diagnosis (in spite of a less sensitive IgM detection than by MAC-ELISA), for surveillance and sero-epidemiologic studies, and for studies of IgG and IgM responses to Mayaro infection.
Resumo:
Ferromagnetic dacron is proposed as an alternative solid-phase for magnetic enzyme immunoassays. Human serum albumin (HSA) was covalentlyimmobilized onto ferromagnetic dacron and as enzyme immunoassay was developed using anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used anti-HSA rabbit sera. Peroxidase, o-phenylenediamine (OPD) and hydrogen peroxide were used as the enzymatic label and substrates, respectively. Best results were observed when particles of 63-100 µm (diameter) and 10 µg of immobilized antigen were used. Positive reactions were detected until dilutions of1:51200 of immune sera. Its reproducibility was similar to standard ELISA. Disruption of the immunocomplexes formed and recuperation of the immobilized antigen in other immunoassays also proved to be reliable.
Resumo:
Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.
Resumo:
Seven swine were experimentally infected with Taenia solium eggs and blood samples from each animal were periodically collected. At the end of the experiment (t140) the animals did not show clinical aspects of cysticercosis or parasites in tongue inspection. All animals were slaughtered and cut into thin slices in searching for cysts. The number of cysts found in each animal varied from 1 to 85. Enzyme-linked immunosorbent assay (ELISA) tests for antibody (Ab) detection and for antigen (Ag) detection were performed, which presented respectively 71 and 57% of positivity. By immunoblot (IB), using 18/14(T. crassiceps Ag) or lentil-lectin-purified glycoproteins from T. solium Ag (LLGP) as Ag, five (71%) and six (86%) animals were positive, respectively. The association between Ag-ELISA with any IB (18/14 or LLGP) allowed the detection of all animals at 140 days post-experimental infection (days p.e.i.). The use of IB 18/14 combined to the Ag-ELISA allowed the detection of all animals since 70 days p.e.i., and the association between IB LLGP and Ag-ELISA allowed the detection of all animals since 112 days p.e.i. While all animals could be considered healthy by conventional screening tests, the use of immunoassays for detecting Ab and Ag showed better accuracy; therefore it would be more useful than usual clinical examination for screening cysticercosis in slightly infected pigs.
Resumo:
BACKGROUND: Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information. Whereas activity assays measure only active renin, immunoassays measure both active and inhibited renin. Particular care must be taken in the collection and processing of blood samples and in the performance of these assays to avoid errors in renin measurement. Both activity assays and immunoassays are susceptible to renin overestimation due to prorenin activation. In addition, activity assays performed with peptidase inhibitors may overestimate the degree of inhibition of PRA by renin inhibitor therapy. Moreover, immunoassays may overestimate the reactive increase in plasma renin concentration in response to renin inhibitor therapy, owing to the inhibitor promoting conversion of prorenin to an open conformation that is recognized by renin immunoassays. CONCLUSIONS: The successful application of renin assays to patient care requires that the clinician and the clinical chemist understand the information provided by these assays and of the precautions necessary to ensure their accuracy.
Resumo:
Streptavidin, a tetrameric protein secreted by Streptomyces avidinii, binds tightly to a small growth factor biotin. One of the numerous applications of this high-affinity system comprises the streptavidin-coated surfaces of bioanalytical assays which serve as universal binders for straightforward immobilization of any biotinylated molecule. Proteins can be immobilized with a lower risk of denaturation using streptavidin-biotin technology in contrast to direct passive adsorption. The purpose of this study was to characterize the properties and effects of streptavidin-coated binding surfaces on the performance of solid-phase immunoassays and to investigate the contributions of surface modifications. Various characterization tools and methods established in the study enabled the convenient monitoring and binding capacity determination of streptavidin-coated surfaces. The schematic modeling of the monolayer surface and the quantification of adsorbed streptavidin disclosed the possibilities and the limits of passive adsorption. The defined yield of 250 ng/cm2 represented approximately 65 % coverage compared with a modelled complete monolayer, which is consistent with theoretical surface models. Modifications such as polymerization and chemical activation of streptavidin resulted in a close to 10-fold increase in the biotin-binding densities of the surface compared with the regular streptavidin coating. In addition, the stability of the surface against leaching was improved by chemical modification. The increased binding densities and capacities enabled wider high-end dynamic ranges in the solid-phase immunoassays, especially when using the fragments of the capture antibodies instead of intact antibodies for the binding of the antigen. The binding capacity of the streptavidin surface was not, by definition, predictive of the low-end performance of the immunoassays nor the assay sensitivity. Other features such as non-specific binding, variation and leaching turned out to be more relevant. The immunoassays that use a direct surface readout measurement of time-resolved fluorescence from a washed surface are dependent on the density of the labeled antibodies in a defined area on the surface. The binding surface was condensed into a spot by coating streptavidin in liquid droplets into special microtiter wells holding a small circular indentation at the bottom. The condensed binding area enabled a denser packing of the labeled antibodies on the surface. This resulted in a 5 - 6-fold increase in the signal-to-background ratios and an equivalent improvement in the detection limits of the solid-phase immunoassays. This work proved that the properties of the streptavidin-coated surfaces can be modified and that the defined properties of the streptavidin-based immunocapture surfaces contribute to the performance of heterogeneous immunoassays.
Resumo:
Several bioaffinity assays are based on the detection of an analyte which is bound on a solid substrate via biochemical interaction. These so called solid phase assays are based on the adhesion of the primary binding partner on a solid surface, which then binds the analyte to be detected. In this thesis work a novel solid phase based assay technology, known as spot technology, was developed. The spot technology is based on combination of high-capacity solid phases, concentrated in a spot format, utilising modified streptavidin molecules and recombinant antibody fragments. The reduction of the solid phase binding surface to a size of a spot enabled denser binding of the target molecules, providing improved signal intensities and signal-to-background ratio when applied in different solid phase immunoassays. Streptavidin-biotin interactions are commonly utilised in numerous different bioaffinity assays and the ultimate nature of streptavidin to bind biotin is among the strongest non-covalent interaction reported between two biomolecules. In this study native core streptavidin was chemically modified to provide polymerised streptavidin molecules with altered adsorption properties. These streptavidin conjugates, when coated onto polystyrene surface, provided enhanced biotin binding capacity and surface stability when compared to a reference coating constructed with native streptavidin. Furthermore, the combination of chemically modified streptavidin, sitespecifically biotinylated antibody fragments and the spot coating technology provided highly dense solid phase coating with improved binding properties. The performance of the spot assay technology was further demonstrated in different immunoassay configurations. Human thyroid stimulating hormone (TSH) and human cardiac troponin I (cTnI) were used as model analytes to show the applicability of the highly sensitive spot-based solid-phase immunoassay for detection of very low levels of analytes. It was demonstrated that the spot technology provided an assay concept with enhanced sensitivity and short turn-around times, characteristics that are highly suitable for point-of-care applications.
Resumo:
Cardiac troponins (cTn) I and T are the current golden standard biochemical markers in the diagnosis and risk stratification of patients with suspected acute coronary syndrome. During the past few years, novel assays capable of detecting cTn‐concentrations in >50% of apparently healthy individuals have become readily available. With the emerging of these high sensitivity cTn assays, reductions in the assay specificity have caused elevations in the measured cTn levels that do not correlate with the clinical picture of the patient. The increased assay sensitivity may reveal that various analytical interference mechanisms exist. This doctoral thesis focused on developing nanoparticle‐assisted immunometric assays that could possibly be applied to an automated point‐of‐care system. The main objective was to develop minimally interference‐prone assays for cTnI by employing recombinant antibody fragments. Fast 5‐ and 15‐minute assays for cTnI and D‐dimer, a degradation product of fibrin, based on intrinsically fluorescent nanoparticles were introduced, thus highlighting the versatility of nanoparticles as universally applicable labels. The utilization of antibody fragments in different versions of the developed cTnI‐assay enabled decreases in the used antibody amounts without sacrificing assay sensitivity. In addition, the utilization of recombinant antibody fragments was shown to significantly decrease the measured cTnI concentrations in an apparently healthy population, as well as in samples containing known amounts of potentially interfering factors: triglycerides, bilirubin, rheumatoid factors, or human anti‐mouse antibodies. When determining the specificity of four commercially available antibodies for cTnI, two out of the four cross‐reacted with skeletal troponin I, but caused crossreactivity issues in patient samples only when paired together. In conclusion, the results of this thesis emphasize the importance of careful antibody selection when developing cTnI assays. The results with different recombinant antibody fragments suggest that the utilization of antibody fragments should strongly be encouraged in the immunoassay field, especially with analytes such as cTnI that require highly sensitive assay approaches.