642 resultados para Hyperglycemic clamp
Resumo:
The metabolic syndrome and type 1 diabetes are associated with brain alterations such as cognitive decline brain infarctions, atrophy, and white matter lesions. Despite the importance of these alterations, their pathomechanism is still poorly understood. This study was conducted to investigate brain glucose and metabolites in healthy individuals with an increased cardiovascular risk and in patients with type 1 diabetes in order to discover more information on the nature of the known brain alterations. We studied 43 20- to 45-year-old men. Study I compared two groups of non-diabetic men, one with an accumulation of cardiovascular risk factors and another without. Studies II to IV compared men with type 1 diabetes (duration of diabetes 6.7 ± 5.2 years, no microvascular complications) with non-diabetic men. Brain glucose, N-acetylaspartate (NAA), total creatine (tCr), choline, and myo-inositol (mI) were quantified with proton magnetic resonance spectroscopy in three cerebral regions: frontal cortex, frontal white matter, thalamus, and in cerebellar white matter. Data collection was performed for all participants during fasting glycemia and in a subgroup (Studies III and IV), also during a hyperglycemic clamp that increased plasma glucose concentration by 12 mmol/l. In non-diabetic men, the brain glucose concentration correlated linearly with plasma glucose concentration. The cardiovascular risk group (Study I) had a 13% higher plasma glucose concentration than the control group, but no difference in thalamic glucose content. The risk group thus had lower thalamic glucose content than expected. They also had 17% increased tCr (marker of oxidative metabolism). In the control group, tCr correlated with thalamic glucose content, but in the risk group, tCr correlated instead with fasting plasma glucose and 2-h plasma glucose concentration in the oral glucose tolerance test. Risk factors of the metabolic syndrome, most importantly insulin resistance, may thus influence brain metabolism. During fasting glycemia (Study II), regional variation in the cerebral glucose levels appeared in the non-diabetic subjects but not in those with diabetes. In diabetic patients, excess glucose had accumulated predominantly in the white matter where the metabolite alterations were also the most pronounced. Compared to the controls values, the white matter NAA (marker of neuronal metabolism) was 6% lower and mI (glia cell marker) 20% higher. Hyperglycemia is therefore a potent risk factor for diabetic brain disease and the metabolic brain alterations may appear even before any peripheral microvascular complications are detectable. During acute hyperglycemia (Study III), the increase in cerebral glucose content in the patients with type 1 diabetes was, dependent on brain region, between 1.1 and 2.0 mmol/l. An every-day hyperglycemic episode in a diabetic patient may therefore as much as double brain glucose concentration. While chronic hyperglycemia had led to accumulation of glucose in the white matter, acute hyperglycemia burdened predominantly the gray matter. Acute hyperglycemia also revealed that chronic fluctuation in blood glucose may be associated with alterations in glucose uptake or in metabolism in the thalamus. The cerebellar white matter appeared very differently from the cerebral (Study IV). In the non-diabetic men it contained twice as much glucose as the cerebrum. Diabetes had altered neither its glucose content nor the brain metabolites. The cerebellum seems therefore more resistant to the effects of hyperglycemia than is the cerebrum.
Resumo:
To identify early metabolic abnormalities in type 2 diabetes mellitus, we measured insulin secretion, sensitivity to insulin, and hepatic insulin extraction in 48 healthy normal glucose-tolerant Brazilians, first-degree relatives of type 2 diabetic patients (FH+). Each individual was matched for sex, age, weight, and body fat distribution with a person without history of type 2 diabetes (FH-). Both groups were submitted to a hyperglycemic clamp procedure (180 mg/dl). Insulin release was evaluated in its two phases. The first was calculated as the sum of plasma insulin at 2.5, 5.0, 7.5, and 10.0 min after the beginning of glucose infusion, and the second as the mean plasma insulin level in the third hour of the clamp procedure. Insulin sensitivity index (ISI) was the mean glucose infusion rate in the third hour of the clamp experiment divided by the mean plasma insulin concentration during the same period of time. Hepatic insulin extraction was determined under fasting conditions and in the third hour of the clamp procedure as the ratio between C-peptide and plasma insulin levels. FH+ individuals did not differ from FH- individuals in terms of the following parameters [median (range)]: a) first-phase insulin secretion, 174 (116-221) vs 207 (108-277) µU/ml, b) second-phase insulin secretion, 64 (41-86) vs 53 (37-83) µU/ml, and c) ISI, 14.8 (9.0-20.8) vs 16.8 (9.0-27.0) mg kg-1 min-1/µU ml-1. Hepatic insulin extraction in FH+ subjects was similar to that of FH- ones at basal conditions (median, 0.27 vs 0.27 ng/µU) and during glucose infusion (0.15 vs 0.15 ng/µU). Normal glucose-tolerant Brazilian FH+ individuals well-matched with FH- ones did not show defects of insulin secretion, insulin sensitivity, or hepatic insulin extraction as tested by hyperglycemic clamp procedures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: To better understand the pathogenesis of type 2 diabetes mellitus, insulin secretion and insulin sensitivity (IS) were evaluated in white Brazilians with impaired glucose tolerance (IGT), using the oral glucose tolerance test (OGTT) and the hyperglycemic clamp technique.Methods: Twenty-five IGT subjects were individually matched with normal glucose-tolerant (NGT) subjects for demographic characteristics, At first, they were submitted to the OGTT and plasma glucose and insulin were measured. of the 25 pairs, 20 could participate in the hyperglycemic clamp procedures, at a second visit. All participants had their plasma glucose levels equally increased to 180 mg/dl; this was maintained for three hours by variable glucose infusion. During the procedure, plasma glucose and insulin were measured at established intervals.Results: In the postabsorptive state, the IGT subjects presented higher levels of plasma glucose, blood HbA(1) and serum triglycerides, but similar plasma insulin levels. After the oral glucose load, early and total insulin release, in relation to glucose levels, were respectively, 43 and 67% lower in the IGT individuals, the index of whole-body IS was increased in the IGT individuals (4.36 +/- 1.71 vs 3.61 +/- 1.28 mg(-1).muU(-1) 100.ml(2); p < 0.05). By the hyperglycemic clamp technique first- (82 &PLUSMN; 26 vs 215 &PLUSMN; 88 μU/ml; p < 0.001) and second- (36 +/- 19 vs 73 +/- 44 muU/ml; p < 0.05) phases of insulin secretion was decreased in the IGT individuals, especially the first one. However, the groups did not differ in relation to the IS: IGT = 13.52 &PLUSMN; 7.27 and NGT = 9.96 &PLUSMN; 6.70 mg.ml/kg.μU.min(-1); p > 0.05. Functional relationship of IS (y) on first-phase insulin release (x) showed a smaller (p < 0,05) regression coefficient for the IGT group.Conclusion: Brazilians with IGT well-matched with NGT ones were characterized by impaired first- and second-phase insulin secretion (mainly the former), while defects in IS were not evident.
Resumo:
Background. To evaluate insulin release and insulin sensitivity in women with prior gestational diabetes mellitus (GDM) to gain a better understanding of type 2 diabetes pathogenesis.Methods. GDM women were individually matched for age, body mass index, and waist/hip ratio with those who were normal glucose tolerant in a previous pregnancy (NGT). All women presented with normal glucose tolerance. Twenty pairs were submitted to the oral glucose tolerance test (OGTT) with plasma glucose, insulin, and C-peptide determinations. of the 20 pairs, 18 participated in hyperglycemic (10.0 mmol/l) clamp experiments with frequent plasma glucose and insulin determinations, allowing us to calculate first- and second-phase insulin release and the insulin sensitivity index. GDM and NGT women were compared using Student's t-test, the Mann-Whitney U-test, Friedman's non-parametric test, and the two proportion test for independent groups.Results. GDM women showed higher glycosylated hemoglobin values; at OGTT, they showed late insulin peak with increased plasma insulin levels only during the second hour, and a similar plasma C-peptide response despite a higher plasma glucose curve; during hyperglycemic clamp procedures, they showed similar biphasic insulin release and insulin sensitivity index. Considering that a woman with previous GDM had a defect in insulin release and/or insulin sensitivity, if its magnitude was at least 25% lower than that of the matched NGT woman, 43.8% showed impairment of first-phase insulin release and 55.6% insulin resistance.Conclusions. GDM women showed some degree of glucose intolerance. It is therefore necessary to follow them for a longer time.
Resumo:
We evaluated insulin release and insulin sensitivity in women with basal and/or postprandial hyperglycemia but normal oral glucose tolerance test (OGTT) in previous pregnancy (GHG). These women were individually matched with females without previous hyperglycemia (NGT). Both groups consisted of normal glucose-tolerant women at the time of this study. They underwent OGTT (75g; n= 32 pairs) and hyperglycemic clamp experiments (10mmoll-1; n=27 pairs) with plasma glucose, insulin, and C-peptide measurements and calculation of insulinogenic index, first- and second-phase insulin release, and insulin sensitivity index (ISI). The GHG group showed higher glycosylated hemoglobin levels (6.2±0.6% versus 5.8±0.8%; P<0.05); lower insulinogenic index at 30min (134.03±62.69pmolmmol-1 versus 181.59±70.26pmolmmoll-1; P<0.05) and diminished C-peptide response in relation to glucose (4.05±0.36nmolmmol-1 versus 4.23±0.36nmolmmol-1; P<0.05) at OGTT. Both groups did not show difference in insulin secretion and ISI by hyperglycemic clamp technique. We concluded that in up to 12 years from index pregnancy, women with previous GHG, presenting normal glucose tolerance and well-matched with their controls, showed β-cell dysfunction without change in ISI. As women with previous GHG are at risk of type 2 diabetes, β-cell dysfunction may be its primary defect. © 2003 Elsevier B.V. All rights reserved.
Resumo:
Exenatide extended-release (ER) is a microencapsulated formulation of the glucagon-like peptide 1-receptor agonist exenatide: It has a protracted pharmacokinetic profile that allows a once-weekly injection with comparable efficacy to insulin with an improved safety profile in type II diabetic people. Here, we studied the pharmacology of exenatide ER in 6 healthy cats. A single subcutaneous injection of exenatide ER (0.13 mg/kg) was administered on day 0. Exenatide concentrations were measured for 12 wk. A hyperglycemic clamp (target = 225 mg/dL) was performed on days 7 (clamp I) and 21 (clamp II) with measurements of insulin and glucagon concentrations. Glucose tolerance was defined as the amount of glucose required to maintain hyperglycemia during the clamp. Continuous glucose monitoring was performed on weeks 0, 2, and 6 after injection. Plasma concentrations of exenatide peaked at 1 h and 4 wk after injection. Comparing clamp I with clamp II, fasting blood glucose decreased (mean standard deviation = 11 8 mg/dL, P = 0.02), glucose tolerance improved (median [range] +33% 14%-138%], P = 0.04), insulin concentrations increased (+36.5% [-9.9% to 274.1%], P = 0.02), and glucagon concentrations decreased (-4.7% [0%-12.1%], P = 0.005). Compared with preinjection values on continuous glucose monitoring, glucose concentrations decreased and the frequency of readings <50 mg/dL increased at 2 and 6 wk after injection of exenatide ER. This did not correspond to clinical hypoglycemia. No other side effects were observed throughout the study. Exenatide ER was safe and effective in improving glucose tolerance 3 wk after a single injection. Further evaluation is needed to determine its safety, efficacy, and duration of action in diabetic cats. (C) 2015 Elsevier Inc. All rights reserved.
Resumo:
The optimal exercise modality for reductions of abdominal obesity and risk factors for type 2 diabetes in youth is unknown. We examined the effects of aerobic exercise (AE) versus resistance exercise (RE) without caloric restriction on abdominal adiposity, ectopic fat, and insulin sensitivity and secretion in youth. Forty-five obese adolescent boys were randomly assigned to one of three 3-month interventions: AE, RE, or a nonexercising control. Abdominal fat was assessed by magnetic resonance imaging, and intrahepatic lipid and intramyocellular lipid were assessed by proton magnetic resonance spectroscopy. Insulin sensitivity and secretion were evaluated by a 3-h hyperinsulinemic-euglycemic clamp and a 2-h hyperglycemic clamp. Both AE and RE prevented the significant weight gain that was observed in controls. Compared with controls, significant reductions in total and visceral fat and intrahepatic lipid were observed in both exercise groups. Compared with controls, a significant improvement in insulin sensitivity (27%) was observed in the RE group. Collapsed across groups, changes in visceral fat were associated with changes in intrahepatic lipid (r = 0.72) and insulin sensitivity (r = -0.47). Both AE and RE alone are effective for reducing abdominal fat and intrahepatic lipid in obese adolescent boys. RE but not AE is also associated with significant improvements in insulin sensitivity.
Resumo:
A compact clamp-type high pressure cell for carrying out electrical conductivity measurements on small solid samples of size 1 mm or less at pressures upto 8 GPa (i.e., 80 kbar) and for use down to 77 K has been designed and fabricated. The pressure generated in the sample region has been calibrated at room temperature against the polymorphic phase transitions of Bismuth and Ytterbium. The pressure relaxation of the clamp at low temperatures has been estimated by monitoring the electrical conductivity behavior of lead. Review of Scientific Instruments is copyrighted by The American Institute of Physics.
Resumo:
Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5, unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic free operation is obtained. The results are verified experimentally.
Resumo:
Single molecule force clamp experiments are widely used to investigate how enzymes, molecular motors, and other molecular mechanisms work. We developed a dual-trap optical tweezers instrument with real-time (200 kHz update rate) force clamp control that can exert 0–100 pN forces on trapped beads. A model for force clamp experiments in the dumbbell-geometry is presented. We observe good agreement between predicted and observed power spectra of bead position and force fluctuations. The model can be used to predict and optimize the dynamics of real-time force clamp optical tweezers instruments. The results from a proof-of-principle experiment in which lambda exonuclease converts a double-stranded DNA tether, held at constant tension, into its single-stranded form, show that the developed instrument is suitable for experiments in single molecule biology.
Resumo:
This paper deals with the system oriented analysis, design, modeling, and implementation of active clamp HF link three phase converter. The main advantage of the topology is reduced size, weight, and cost of the isolation transformer. However, violation of basic power conversion rules due to presence of the leakage inductance in the HF transformer causes over voltage stresses across the cycloconverter devices. It makes use of the snubber circuit necessary in such topologies. The conventional RCD snubbers are dissipative in nature and hence inefficient. The efficiency of the system is greatly improved by using regenerative snubber or active clamp circuit. It consists of an active switching device with an anti-parallel diode and one capacitor to absorb the energy stored in the leakage inductance of the isolation transformer and to regenerate the same without affecting circuit performance. The turn on instant and duration of the active device are selected such that it requires simple commutation requirements. The time domain expressions for circuit dynamics, design criteria of the snubber capacitor with two conflicting constrains (over voltage stress across the devices and the resonating current duration), the simulation results based on generalized circuit model and the experimental results based on laboratory prototype are presented.
Resumo:
Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5 unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters, due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic-free operation is obtained. The results are verified experimentally.
Resumo:
Bacterial DNA topoisomerase I (topoI) catalyzes relaxation of negatively supercoiled DNA. The enzyme alters DNA topology through protein-operated DNA gate, switching between open and closed conformations during its reaction. We describe the mechanism of inhibition of Mycobacterium smegmatis and Mycobacterium tuberculosis topoI by monoclonal antibodies (mAbs) that bind with high affinity and inhibit at 10-50 nM concentration. Unlike other inhibitors of topoisomerases, the mAbs inhibited several steps of relaxation reaction, namely DNA binding, cleavage, strand passage, and enzyme-DNA dissociation. The enhanced religation of the cleaved DNA in presence of the mAb indicated closing of the enzyme DNA gate. The formation of enzyme-DNA heterocatenane in the presence of the mAbs as a result of closing the gate could be inferred by the salt resistance of the complex, visualized by atomic force microscopy and confirmed by fluorescence measurements. Locking the enzyme-DNA complex as a closed clamp restricted the movements of the DNA gate, affecting all of the major steps of the relaxation reaction. Enzyme trapped on DNA in closed clamp conformation formed roadblock for the elongating DNA polymerase. The unusual multistep inhibition of mycobacterial topoisomerases may facilitate lead molecule development, and the mAbs would also serve as valuable tools to probe the enzyme mechanism.