895 resultados para Dwellings -- Heating and ventilation -- Environmental aspects


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis project, a building in Vegagatan 12, Gävle has been analysed in order to see why it does consume more energy than it was expected. This building is a low energy building certified by Miljöbyggnad and it should use less than 55kWh/m2 year and nowadays it is using 62.23 kWh/m2. To get the needed data, some information about the building has been gathered, some measurements have been done in the building and some calculations have been done with those measurements. Finally, some possible solutions have been offered to reduce the energy use of the building. Insulating the floor, the pipes and the walls, reducing the indoor temperature in winter... All of these changes need the help of environmentally friendly attitudes, which is a very important fact in low energy buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Published by: National Trade Journals, -1929.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

År 2006 införde Boverket, som lyder under regeringen krav för specifik energianvändning (kWh/m2år) för byggnader i syfte att minska energianvändningen för bostäder och lokaler. För att följa Boverkets krav för specifik energianvändning är det därför relevant att bygga mer energieffektiva byggnader. Naturmuseet Vänern är en byggnad i Karlstad som befinner sig vid Vänern. Byggnaden är omgiven av en naturskön miljö och dess verksamhet är huvudsakligen ett museum. Som helhet är Naturmuseet Vänern högt i tak och har stora fönsterytor vilket leder till att byggnaden behöver kylas på grund av den stora mängden solinstrålning. För att hålla sig till en låg specifik energianvändning är det därför relevant att hitta ett hållbart kylsystem. För att en byggnad ska bli energieffektiv i ett klimat såsom det i Sverige krävs ett byggnadsmaterial med lågt U-värde samt väl anpassade systemlösningar för värme, ventilation och kyla. Utifrån datorprogrammet VIP-Energy har en energianalys gjorts för Naturmuseet Vänern, vilket legat som grund för byggnadens utformning samt valet av byggnadsmaterial och kylsystem. Resultatet har utöver hur byggandes klimatskal ska se ut även landat i systemhandlingar i form av ritningar, driftstrategi och materialspecifikation för kylsystemet. Den lägsta specifika energianvändningen för Naturmuseet Vänern är 37 kWh/m2år, vilket fås då bergkyla väljs som kylsystem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Visceral leishmaniasis (VL) stands out as a zoonosis observed on four continents and also in urban expansion zones in several regions of Brazil. Methods A cross-sectional epidemiological study of VL cases in children under 15 years of age in the period from 2007 to 2012. Clinical data were gathered from medical reports; meteorological data were obtained at the Meteorological Measurement Department of UFT. Environmental variables were divided into two periods, rainy and dry. Results The study revealed no difference by gender (p=0.67) among the 821 patients. However, the most affected age group was between one and five years of age (58.6%; p<0.01); the highest prevalence of the disease (99.03%; p<0.01) occurred in urban zones; and the most affected ethnic group (85.5%; p<0.01) was mixed race. The highest incidence coefficients in this population occurred in 2007 and 2008 (578.39/100,000 inhabitants; 18.5/100,000 inhabitants, respectively), whereas the highest lethality coefficients occurred in 2008 and 2011 (0.85/100 deaths). There was no significant correlation between average rainfall and the number of VL cases. The correlation between temperature and number of VL cases was negative (r = -0.4039; p<0.01). Conclusions In Araguaína, visceral leishmaniasis in children under 15 years is an urban-based endemic disease distributed across all districts of the city wherein temperature as an environmental factor, a higher prevalence in mixed race children between one and five years of age, and a high incidence coefficient all strongly contribute to child mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoite onharmonisoida yhtenäiset rakenteet UPM:n paperi- ja sellutehtaiden merkittävilleympäristönäkökohdille sekä niiden ympäristöriskienhallintajärjestelmille. Näin saavutetaan yhteneväiset tavoitteet ja analysointikeinot yrityksen yksiköille. Harmonisointiprosessi on osa koko yrityksen ympäristöhallintajärjestelmän kehittämistä. Ja konsernin EMS -prosessi puolestaan konvergoi konsernin integroidun johtamisjärjestelmän kehitystä. Lisäksi työn tapaustutkimuksessa selvitettiin riskienhallintajärjestelmien integroitumispotentiaalia. Sen avulla saavutettaisiin paremmin suuren yrityksen synergia-etuja ja vuorovaikutteisuutta toimijoiden kesken, sekä parannettaisiin riskienhallintajärjestelmän mukautuvuutta ja käytettävyyttä. Työssä käsitellään kolmea esimerkkiä, joiden pohjalta tehdään esitys harmonisoiduille merkittäville ympäristönäkökohdille sekä riskienhallintajärjestelmien parametreille. Tutkimusongelmaa lähestytään haastattelujen, kirjallisuuden, yrityksen PWC:llä teettämän selvityksen sekä omien päätelmien avulla. Lisäksi työssä esitetään ympäristöhallintajärjestelmän tehokkuuden todentaminen ympäristösuorituskyvyn muuttujiin suhteutettuna. Pohjana jatkuvan kehityksen päämäärälle on organisaatio-oppiminen, niin yksittäisen työntekijän, tiimien kuin eri yksiköiden kesken. Se antaa sysäyksen aineettoman omaisuuden, kuten ympäristö-osaamisen, hyödyntämiseen parhaalla mahdollisella tavalla. Tärkeimpinä lopputuloksina työssä ovat ehdotukset harmonisoiduille merkittäville ympäristönäkökohdille sekä ympäristöriskienhallintajärjestelmän määritetyille komponenteille. Niitä ovat määritelmät ja skaalat riskien todennäköisyydelle, seurauksille sekä riskiluokille. Työn viimeisenä osana luodaan pohja tapaustutkimuksen avulla Rauman tehtaan jätevedenpuhdistamon kahden erilaisen riskienhallintajärjestelmän integroitumiselle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve CO2 emissions reductions the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure (SAP 2005) or, more recently SAP 2009. SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption. However, these calculations are rarely verified with real energy consumption and related CO2 emissions. This paper presents the results of an analysis based on weekly head demand data for more than 200 individual flats. The data is collected from recently built residential development connected to a district heating network. A methodology for separating out the domestic hot water use (DHW) and space heating demand (SH) has been developed and compares measured values to the demand calculated using SAP 2005 and 2009 methodologies. The analysis shows also the variance in DHW and SH consumption between both size of the flats and tenure (privately owned or housing association). Evaluation of the space heating consumption includes also an estimation of the heating degree day (HDD) base temperature for each block of flats and its comparison to the average base temperature calculated using the SAP 2005 methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present paper deals with environmental degradation in the city of Guaratingueta, Brazil; as a result of disordered urban settlement and development. Three site areas in the city resting on different geologic units were selected for the analyses, i.e.: precambrian rocks, tertiary sedimentary basin, and recent quaternary soil deposits. It has been found that geological and geotechnical aspects are fundamental to form the basis for environmental preservation and urban planning.