997 resultados para Dental impression techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose This in vitro study compared the dimensional accuracy of two impression techniques Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant supported pros theses Materials and Methods A master cast with four parallel implant abutment analogs and a passive framework were fabricated Vinyl polysiloxane impression material was used for all impressions with a metal stock tray Two groups (D and M) were tested (n = 5) The measurement method employed was just one titanium screw tightened to the framework Each group s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at X100 magnification The results were analyzed statistically (t test) Results The mean values of abutment/framework interface gaps were master cast = 32 mu m (SD 2), group D = 165 mu m (SD 60), and group M = 69 mu m (SD 36) There was a statistically significant difference between the D and M groups (P <= 001) Conclusion Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings INT J ORAL MAXILLOFAC IMPLANTS 2010 25 1153-1158

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (1), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at x 100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, alpha = .05). Results: The mean abutment/framework interface gaps were: master cast = 31.63 mu m; group I = 45.25 mu m; group S = 96.14 mu m; group MS = 51.20 mu m. No significant difference was detected among the index and modified squared techniques (P = .05). Conclusion: Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:715-721

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate, in vitro, the dimensional accuracy of two impression techniques (squared impression copings and squared impression copings sandblasted and coated with impression adhesive) made of vinyl polysiloxane and polyether impression materials. Materials and Methods: A master cast (control group) with four parallel implant abutment analogs, a passive framework, and a custom aluminum tray was fabricated. Four groups (n = 5 each group) were tested: squared Impregum (SI), squared Express (SE), sandblasted adhesive squared Impregum (ASI), and sandblasted adhesive squared Express (ASE). The measurement method employed was just one titanium screw tightened to the framework. A stereomicroscope was used to evaluate the fit of the framework by measuring the size of the gap between the abutment and the framework. The results were analyzed statistically. Results: The mean values for the abutment/framework interface gaps were: master cast, 31.63 mu m (SD 2.16); SI, 38.03 mu m (SD 9.29); ASI, 46.80 mu m (SD 8.47); SE, 151.21 mu m (SD 22.79); and ASE, 136.59 mu m (SD 29.80). No significant difference was detected between the SI or ASI techniques and the master cast. No significant difference was detected between the SE and ASE techniques. Conclusion: Within the limitations of this study, it can be concluded that Impregum Soft medium consistency was the best impression material and the impression technique did not influence the accuracy of the stone casts. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:771-776

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 62-year-old man was referred for routine treatment of hyperplasia of the mucosa in the anterior lower jaw. An oroantral fistula was detected in the right superior alveolar ridge. The patient had no complaints. Plain radiographs showed a radiopaque foreign body in the posterior region associated with opacification of the maxillary sinus. Computed tomography showed the same hyperdense foreign body located in the posterior lower part of the sinus and an abnormal soft tissue mass in the entire right maxillary sinus. When asked about sinusitis, the patient mentioned occasional episodes of pus taste and intermittent crises of headache lasting for one week. The patient has been edentulous for 20 years. Sinus debridement was performed and the oroantral fistula was closed. The clinical suspicion of the presence of zinc oxide-eugenol paste was confirmed by microscopical and chemical analysis. After 6 months of follow-up, the fistula continued to be closed and sinusitis did not recur. This clinical case of maxillary chronic sinusitis illustrates a different odontogenic origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.