994 resultados para CE-ESI-MS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metabolomics has become an invaluable tool to unveil biology of pathogens, with immediate application to chemotherapy. It is currently accepted that there is not one single technique capable of obtaining the whole metabolic fingerprint of a biological system either due to their different physical-chemical properties or concentrations. In this work, we have explored the capability of capillary electrophoresis mass spectrometry with a sheathless interface with electrospray ionization (CE-ESI-TOF-MS) to separate metabolites in order to be used as a complementary technique to LC. As proof of concept, we have compared the metabolome of Leishmania infantum promastigotes BCN 150 (Sb (III) IC50 = 20.9 mu M) and its variation when treated with 120 mu M of Sb(III) potassium tartrate for 12 h, as well as with its Sb(III) resistant counterpart obtained by growth of the parasites under increasing Sb(III) in a step-wise manner up to 180 mu M. The number of metabolites compared were of 264 for BCN150 Sb(III) treated versus nontreated and of 195 for Sb(III) resistant versus susceptible parasites. After successive data filtering, differences in seven metabolites identified in databases for Leishmania pathways, showed the highest significant differences, corresponding mainly to amino acids or their metabolite surrogates. Most of them were assigned to sulfur containing amino acids and polyamine biosynthetic pathways, of special relevance considering the deterioration of the thiol-dependent redox metabolism in Leishmania by Sb(III). Given the low concentrations typical for most of these metabolites, the assay can be considered a success that should be explored for new biological questions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood doping involves the use of products that enhance the uptake, transport, or delivery of oxygen to the blood. One approach uses artificial oxygen carriers, known as hemoglobin-based oxygen carriers (HBOCs). This study describes an analytical strategy based on CE for detecting intact HBOCs in plasma samples collected for doping control. On-capillary detection was performed by UV/Vis at 415 nm, which offered detection selectivity for hemoproteins (such as hemoglobin and HBOCs). On-line ESI-MS detection with a TOF analyzer was further used to provide accurate masses on CE peaks and to confirm the presence of HBOCs. An immunodepletion sample preparation step was mandatory prior to analysis, in order to remove most abundant proteins that interfered with CE separation and altered the ESI process. This analytical method was successfully applied to plasma samples enriched with Oxyglobin, a commercially available HBOC used for veterinary purposes. Detection limits of 0.20 and 0.45 g/dL were achieved in plasma for CE-UV/Vis at 415 nm and CE-ESI-TOF/MS, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CE is a powerful analytical tool used to separate intact biomolecules such as proteins. The coupling of CE with TOF/MS produces a very promising method that can be used to detect and identify proteins in different matrices. This paper describes an efficient, rapid, and simple CE-ESI-TOF/MS procedure for the analysis of endogenous human growth hormone and recombinant human growth hormone without sample preparation. Operational factors were optimized using an experimental design, and the method was successfully applied to distinguish human growth hormone and recombinant human growth hormone in unknown samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les dernières décennies ont été marquées par une augmentation du nombre des cas de cancers, ce qui a subséquemment conduit à une augmentation dans la consommation des agents de chimiothérapie. La toxicité et le caractère cancérogène de ces molécules justifient l’intérêt crucial porté à leur égard. Quelques études ont fait l’objet de détection et de quantification des agents de chimiothérapie dans des matrices environnementales. Dans ce projet, une méthode utilisant la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS) précédée d’une extraction sur phase solide (SPE) automatisée ou en ligne a été développée pour la détection et la quantification d’un groupe de six agents de chimiothérapie. Parmi ceux-ci figurent les plus utilisés au Québec (gemcitabine, méthotrexate, cyclophosphamide, ifosfamide, irinotécan, épirubicine) et présentant des propriétés physico-chimiques et des structures chimiques différentes. La méthode développée a été validée dans une matrice réelle représentant l’affluent d’une station d’épuration dans la région de Montréal. Deux des six composés cytotoxiques étudiés en l’occurrence (cyclophosphamide et méthotrexate) ont été détectés dans huit échantillons sur les neuf qui ont été recensés, essentiellement au niveau de l’affluent et l’effluent de quelques stations d’épuration de la région de Montréal. Les résultats des analyses effectuées sur les échantillons réels ont montré qu’il n’y avait pas de différence significative dans la concentration entre l’affluent et l’effluent, et donc que les systèmes d’épuration semblent inefficaces pour la dégradation de ces molécules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

in this work, a simple method for the simultaneous determination of cocaine (COC) and five COC metabolites (benzoylecgonine, cocaethylene (CET), anhydroecgonine, anhydroecgonine methyl ester and ecgonine methyl ester) in human urine using CE coupled to MS via electrospray ionization (CE-ESI-MS) was developed and validated. Formic acid at 1 mol/L concentration was used as electrolyte whereas formic acid at 0.05 mol/L concentration in 1:1 methanol:water composed the coaxial sheath liquid at the ESI nozzle. The developed method presented good linearity in the dynamic range from 250 ng/mL to 5000 ng/mL (coefficient of determination greater than 0.98 for all compounds). LODs (signal-to-noise ratio of 3) were 100 ng/mL for COC and CET and 250 ng/mL for the other studied metabolites whereas LOQ`s (signal-to-noise ratio of 10) were 250 ng/mL for COC and CET and 500 ng/mL for all other compounds. Intra-day precision and recovery tests estimated at three different concentration levels (500, 1500 and 5000 ng/mL) provided RSD lower than 10% (except anhydroecgonine, 18% RSD) and recoveries from 83-109% for all analytes. The method was successfully applied to real cases. For the positive urine samples, the presence of COC and its` metabolites was further confirmed by MS/MS experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protein hydrolysates have been used as active principles in cosmetic products conferring different properties to the final formulations, which are mostly controlled by the peptide size and its amino acid sequence. In this work, capillary electrophoresis coupled to mass spectrometry analyses were carried out in order to investigate such characteristics of protein hydrolysates. Samples of different origins (milk, soy and rice) were obtained from a local company, and were analyzed without a previous preparation step. The background electrolyte (BGE) and sheath liquid compositions were optimized for each sample. The best BGE composition (860 mmol/L formic acid - pH 1.8 - in 70: 30 v/v water/methanol hydro-organic solvent) was chosen based on the overall peak resolution whereas the best sheath liquid was selected based on increased sensitivity and presented different compositions to each sample (10.9-217 mmol/L formic acid in 75: 25-25: 75 v/v water/methanol hydro-organic solvent). Most of the putative peptides in the hydrolysate samples under investigation presented molecular masses of 1000 Da or less. De novo sequencing was carried out for some of the analytes, revealing the hydrophobicity/polarity of the peptides. Hence, the technique has proved to be an advantageous tool for the quality control of industrial protein hydrolysates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe herein a general method for the controlled Heck arylation of allylated malonates. Both electron-rich and electron-poor aryldiazonium salts were readily employed as the aryl-transfer agents in good yields and in high chemo-, regio-, and stereoselectivity without formation of decarboxylated byproducts. Reaction monitoring via ESI-MS was used to support the formation of chelated Pd species through the catalytic cycle. Additionally, some Heck adducts were successfully used in the total synthesis of pharmacologically active γ-lactones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New N-p-chloro-, N-p-bromo-, and N-p-nitrophenylazobenzylchitosan derivatives, as well as the corresponding azophenyl and azophenyl-p-sulfonic acids, were synthesized by coupling N-benzylvchitosan with aryl diazonium salts. The synthesized molecules were analyzed by UV-Vis, FT-IR, 1H-NMR and 15N-NMR spectroscopy. The capacity of copper chelation by these materials was studied by AAS. Chitosan and the derivatives were subjected to hydrolysis and the products were analyzed by ESI(+)-MS and GC-MS, confirming the formation of N-benzyl chitosan. Furthermore, the MS results indicate that a nucleophilic aromatic substitution (SnAr) reaction occurs under hydrolysis conditions, yielding chloroaniline from N-p-bromo-, and N-p-nitrophenylazo-benzylchitosan as well as bromoaniline from N-p-chloro-, and N-p-nitrophenylazobenzyl-chitosan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an analytical method for the rapid screening and identification of the phenolic constituents present in the polar extracts of different Lychnophora spp. using LC-UV/DAD-ESI-MS and LC-UV/DAD-ESI-MS/MS. Compounds were identified based on UV, retention time, MS experiments and MS/MS of precursor ion or standard. On-line phytochemical investigation of Lychnophora spp. allowed for the identification of flavonoids, chlorogenic acid derivatives and lactones. Some of the observed compounds were for the first time identified in Lychnophora species in a fast analytical procedure. The data obtained here may be helpful to the investigation of polar constituents from other Lychnophora species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En aquest treball s’investiga la reactivitat de tres complexos de Pt, cisplatí, complex 1, [Pt(dmba)(aza-N1)(dmso)], complex 2, i [Pt(dmba)(N9-9AA)(PPh3)]+, complex 3; els quals presenten activitat antitumoral, amb diferents proteïnes i oligonucleòtids mitjançant espectrometria de masses (ESI-TOF MS). ). L’estudi del cisplatí, 1, droga molt coneguda i emprada avui en dia pel tractament de molts tipus de càncer, permet comparar la reactivitat dels nous complexos d’estudi, 2 i 3, els quals presenten un IC50 més baix que el cisplatí en algunes línies de cèl·lules tumorals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Direct-infusion ESI-MS/MS is a powerful approach for the identification of substances in complex mixtures. The aim of this work was to investigate its applicability to the toxicological screening of blood samples. A simple protein precipitation was used, followed by a 15 min infusion of the extract in the mass spectrometer. RESULTS: The application of the procedure to commercial quality controls and authentic post-mortem blood samples demonstrated that the direct-infusion ESI-MS/MS approach enables the simultaneous identification of substances that require different chromatographic conditions. However, poor sensitivity was observed for benzodiazepine, amphetamines and opiate compounds. CONCLUSION: Considering the facile implementation and positive performance of direct-infusion ESI-MS/MS, this approach may to be a valuable complementary technique for systematic toxicological analysis procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports an HPLC-ESI-MS/MS investigation on the oxidation of 3,5- and 4,5- dicaffeoylquinic acid using iron(III) tetraphenylporphyrin chloride as catalyst. Two major mono-oxidised products of the quinic acid moiety have been identified for both compounds. However, only the 4,5-derivative afforded two different tri-oxo products. Thus, it seems that the oxidation pattern depends on the number and positions of the caffeic acid moieties present in caffeoylquinic acid molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.