999 resultados para Acesso à energia elétrica
Resumo:
Electrical energy today is an essential element in the life of any human being. Through the access to electrical energy it is possible to enjoy dignified conditions of life, having in mind the possibility of making use of minimal material conditions of life. The lack of access to electricity is directly linked to poverty and degrading conditions of life, in which are some communities in Brazil, especially the more isolated from urban centers. Access to the electric service is a determining factor for the preservation of human dignity, constitutional principle inscribe in the art.1 of the Federal Constitution, and the promotion of development, being a right of everyone and a duty of the State to promote universal access. For that reason, focuses mainly on the analysis of their setting as a fundamental social right and its importance for national development. For this, the theoretical and descriptive method was used, with normative and literary analysis, in particular the Constitution of 1988. This study also discusses the form of action of the State in the energy sector, to give effect to the fundamental social right of access to electricity, the characteristics of public service and the principles that guide it, in addition to the role of public policies in universalization of access, in particular the analysis of the Program Luz para Todos, and the function of regulation in the implementation of these policies and the provision of adequate public services.
Resumo:
Em Angola, apenas cerca de 30% da população tem acesso à energia elétrica, nível que decresce para valores inferiores a 10% em zonas rurais mais remotas. Este problema é agravado pelo facto de, na maioria dos casos, as infraestruturas existentes se encontrarem danificadas ou não acompanharem o desenvolvimento da região. Em particular na capital angolana, Luanda que, sendo a menor província de Angola, é a que regista atualmente a maior densidade populacional. Com uma população de cerca de 5 milhões de habitantes, não só há frequentemente problemas relacionados com a falha do fornecimento de energia elétrica como há ainda uma percentagem considerável de municípios onde a rede elétrica ainda nem sequer chegou. O governo de Angola, no seu esforço de crescimento e aproveitamento das suas enormes potencialidades, definiu o setor energético como um dos fatores críticos para o desenvolvimento sustentável do país, tendo assumido que este é um dos eixos prioritários até 2016. Existem objetivos claros quanto à reabilitação e expansão das infraestruturas do setor elétrico, aumentando a capacidade instalada do país e criando uma rede nacional adequada, com o intuito não só de melhorar a qualidade e fiabilidade da rede já existente como de a aumentar. Este trabalho de dissertação consistiu no levantamento de dados reais relativamente à rede de distribuição de energia elétrica de Luanda, na análise e planeamento do que é mais premente fazer relativamente à sua expansão, na escolha dos locais onde é viável localizar novas subestações, na modelação adequada do problema real e na proposta de uma solução ótima para a expansão da rede existente. Depois de analisados diferentes modelos matemáticos aplicados ao problema de expansão de redes de distribuição de energia elétrica encontrados na literatura, optou-se por um modelo de programação linear inteira mista (PLIM) que se mostrou adequado. Desenvolvido o modelo do problema, o mesmo foi resolvido por recurso a software de otimização Analytic Solver e CPLEX. Como forma de validação dos resultados obtidos, foi implementada a solução de rede no simulador PowerWorld 8.0 OPF, software este que permite a simulação da operação do sistema de trânsito de potências.
Resumo:
A universalização do fornecimento de energia elétrica é uma meta ainda distante de ser alcançada na Amazônia brasileira, em face dos obstáculos geográficos, da dispersão de seus habitantes, da indefinição de tecnologias adequadas, além dos aspectos econômicos, em que pese ações governamentais, traduzidas no Programa Luz para Todos - PLpT, criado em 2003, cuja meta é atender a totalidade dos consumidores rurais até 2010, e a determinação da Agência Nacional de Energia Elétrica –ANEEL, responsável no Brasil pela regulação do setor elétrico, da obrigatoriedade da universalização até 2015. Este trabalho descreve pesquisa realizada no rio Madeira, na Amazônia brasileira, em que a geração de energia elétrica para atendimento de comunidades e pequenas cidades ao longo do rio, contribuindo para a universalização, pode ser viabilizada usando como fonte renovável inédita a biomassa lenhosa depositada no fundo do rio, decorrente de processos naturais, cuja retirada faz parte da rotina do Ministério dos Transportes, por obrigação legal, para viabilizar segurança na navegação. Como etapa inicial foram realizadas revisões bibliográficas para dar suporte à fundamentação teórica acerca de sistema elétrico brasileiro, universalização de acesso à energia elétrica, fontes renováveis na Amazônia, tecnologias para geração de eletricidade usando biomassa como fonte, subsídios no setor elétrico do Brasil, o rio Madeira, suas características e importância, além de ferramentas de análise de investimento. Em seguida, foram coletadas informações junto à AHIMOC, órgão responsável pela hidrovia do Madeira, quanto aos dados quantitativos e qualitativos da retirada de biomassa lenhosa do leito desse rio, bem como trabalhos de coleta in locu de amostras dessa biomassa para posterior análise de suas características físico-químicas em laboratório da UFAM. De posse dessas informações procedeu-se a avaliação de potencial de geração de energia elétrica da biomassa, assim como de rotas tecnológicas para tal. Os resultados obtidos das biomassas coletadas serviram como balizadores para confirmação de valores constantes na literatura e foram usados posteriormente na avaliação de potencial de geração de energia elétrica com identificação de rotas tecnológicas para tal. Etapa posterior contemplou a obtenção junto à concessionária de identificação e caracterização de potenciais mercados consumidores localizados na calha do Rio Madeira. Uma vez caracterizada a biomassa disponível, as possíveis rotas tecnológicas e os potenciais mercados consumidores, foram avaliados os aspectos tecnológicos, econômicos, ambientais, sociais e legais envolvidos. O estudo conclui pela competitividade do sistema de gaseificação, podendo contribuir para a universalização do acesso a eletricidade, cuja viabilização depende de adoção de política pública neste sentido, a partir de ações entre os Ministérios dos Transportes, de Minas e Energia e do Meio Ambiente. Conclui, também, pelo potencial de atração de capital privado, o que contribuiria para a redução de gastos públicos. Trabalhos futuros quanto à replicabilidade do estudo em áreas com fenômeno semelhante, bem como de oportunidades de uso de outras biomassas apresentam-se viáveis.
Resumo:
As agências reguladoras se constituíram como a grande inovação institucional da reforma do Estado brasileiro. De modo a suprir o gap de legitimidade que emerge do fato de que tais agências não são controladas diretamente por nenhum representante eleito, seu desenho institucional foi formulado de modo a propiciar mecanismos de participação social. Entre estes, as audiências públicas se constituem no objeto deste estudo. Pergunta-se: a quais interesses serve esse mecanismo de participação social? De modo a responder tal questionamento, é realizada uma análise institucional do mecanismo e um mapeamento dos participantes e das colaborações enviadas às audiências da Agência Nacional de Energia Elétrica (Aneel) (1998-2006). A análise dos dados indica uma sobrerrepresentação dos interesses dos regulados. Por fim, o estudo indica que as audiências públicas permitem a permeabilidade da ação regulatória aos diversos grupos da sociedade. Entretanto, essa permeabilidade demonstra uma tendência seletiva, podendo se constituir numa via de acesso à captura.
Resumo:
A presente dissertação apresenta um conjunto de algoritmos, cujo objetivo é a determinação da capacidade máxima de energia que é possível integrar numa rede de energia elétrica, seja num único nó ou em vários nós simultaneamente. Deste modo, obtém-se uma indicação dos locais mais adequados à nova instalação de geração e quais os reforços de rede necessários, de forma a permitirem a alocação da nova energia. Foram estudados e identificados os fatores que influenciam o valor da capacidade máxima nodal, assim como as suas consequências no funcionamento da rede, em particular o carácter simultâneo associado às referidas injeções nodais. Nesse sentido, são apresentados e desenvolvidos algoritmos que têm em consideração as características técnicas da geração a ligar e as restrições físicas impostas pela rede elétrica existente. Os algoritmos desenvolvidos apresentados baseiam-se em busca gaussiana, tendo sido igualmente implementada uma heurística que tem em consideração a proximidade de outras injeções em nós adjacentes e finalmente, dada a natureza combinatória do problema, propõe-se a aplicação de algoritmos genéticos especificamente adaptados ao problema Conclui-se que os algoritmos genéticos encerram características que lhes permitem ser aplicados em qualquer topologia com resultados superiores a todos os algoritmos desenvolvidos. Os métodos apresentados foram desenvolvidos e implementados usando a linguagem de programação Python, tendo-se desenvolvido ainda um interface visual ao utilizador, baseado em wxPython, onde estão implementadas diversas ferramentas que possibilitam a execução dos algoritmos, a configuração dos seus parâmetros e ainda o acesso à informação resultante dos algoritmos em formato Excel.
Resumo:
A racionalização do consumo de energia elétrica é um tema que assume uma importância crescente nos dias de hoje. O elevado consumo de energia, principalmente a nível comercial/industrial, tem motivado o aparecimento de questões políticas, económico-sociais e ambientais que visam a sensibilização dos consumidores para a gestão eficiente dos seus recursos. Neste sentido, as empresas e instituições têm demonstrado interesse em encontrar soluções de gestão nas suas instalações elétricas que permitam a monitorização de indicadores e a previsão de falhas cuja ocorrência acarreta elevados custos de reparação/substituição, de paragem de produção, entre outros. O estudo aqui apresentado surge no âmbito de um projeto académico, cuja finalidade se prende com a implementação de um sistema de monitorização da qualidade e consumo de energia elétrica no Instituto Superior de Engenharia do Porto (ISEP). Baseado numa rede de dispositivos analisadores de parâmetros de energia elétrica, estes equipamentos de medição dispõem de software próprio, o GridVis, que permite o acesso remoto, através de uma rede Ethernet, aos parâmetros de energia (grandezas físicas elétricas). O sistema desenvolvido é capaz de identificar parâmetros de consumo de energia anómalos e emitir alertas, pré-programados em linguagem C++ e diagrama de blocos. Permite, por exemplo, detetar um consumo instantâneo excessivo de energia e alertar a sua ocorrência. As páginas de acesso aos parâmetros medidos por cada dispositivo são acessíveis através de uma interface gráfica desenvolvida em Adobe Flash que inclui, de uma forma simples e organizada, a informação relativa à distribuição dos dispositivos de medição. Num contexto de expansão deste projeto para outros edifícios do ISEP, a solução desenvolvida encontra-se preparada para ser adaptada em qualquer local, desde que reúna certos requisitos.
Resumo:
Os combustíveis fósseis, como o carvão, o petróleo e o gás, constituem fontes de energia que em breve se esgotarão e que são demasiado caras para serem desperdiçadas pelas centrais elétricas na produção de electricidade. Para além desse facto, existem outros argumentos (sobretudo económicos) que inviabilizam a utilização destas fontes de energia em algumas regiões, abrindo caminho a fontes de energia alternativas (e.g. solar, eólica, biomassa, mini-hídricas, geotérmicas, etc) e preferencialmente com contornos locais. No caso particular de Moçambique, tem-se verificado um interesse crescente por parte do governo e de várias ONGs na promoção do uso de energias alternativas para as zonas onde a energia convencional não chega e não chegará, devido aos custos muito elevados que esse processo acarretaria. Esta dissertação apresenta um estudo aprofundado do dimensionamento dum sistema híbrido de geração de energia elétrica envolvendo gerador FV e grupo eletrogéneo de emergência para a Escola Rural da Nangade, situada no Distrito de Nangade, na Província do Cabo Delgado. São também descritos os diversos componentes e as tecnologias associadas a um sistema deste género, com a inclusão de sistemas inteligentes de controlo de energia com a utilização de inversores bidireccionais (inversores de bateria e carregadores) para sistemas isolados. Os resultados são apresentados de forma a facilitar a aplicação e montagem deste tipo de sistemas in loco. Espera-se que esta dissertação possa servir de base no futuro próximo, para a implementação deste tipo de sistemas para permitir a melhoria da qualidade de ensino através de melhores infraestruturas, democratizando desta forma o acesso à educação para as crianças das zonas rurais das várias províncias de Moçambique. Como as energias renováveis são parte integrante do Sistema Elétrico Nacional, apresenta-se resumidamente, no anexo 17, o “Plano de Desenvolvimento na Área de Energia de Moçambique”.
Resumo:
A modeling of criterias and alternatives is through and applied a questionnaire based on method AHP to proprietors of gas stations. The considered alternatives had been the maintenance of the current state with electric energy of the deliverer and the generation in small scale based on the natural gas. The used criteria had been Cost of the Investment, Final Cost of the Energy, Operational cost, Ambient Benefits, Risk and Variation of Costs. The study it was carried through in the city of Natal, RN in ranks that make use of the natural as for resale, where the generation alternative on the basis of the available gas is present. The main results evidence in a dimension the viability of use of method AHP with questionnaire by means of validation of the judgments with analysis of variance beyond proper the normal mechanisms of analysis of consistency to the method. The main results of the analysis help to show that in this in case that the profile of models of criteria and judgments of the actors is similar, with the final evidence of that it has a dominance of the maintenance of the energy of the deliverer. The main criterion to influence this decision was the risk
Resumo:
This thesis treats of a avaliation of a laboral gimnastics program of a electrical energy enterprise from Rio Grande do Norte. The leading aim of this work is to analyse the laboral gimnastics program with emphasis on functional performing and personal changes of staff of different categories. The work shows two divisions: at first, it was carried out the bibliographic study approaching the concepts and historic about the ergonomy and the main focus of study, the laboral gimnastics , performing factors and lifestyle.The second time , it was carried out the field study where was used a questionnaire to a 160 staff population which participate of laboral gymnastics program; then the data were analysed through three statistics analyses: multivaried__ clusters, qui-quadrado and multiple linear regression. The results aim to the confirmation that the laboral gymnastics program developed two years ago on enterprise proposes to the white-collar and operational workers an improving on their functional performing and also, to the changes in some aspects of lifestyle, like the food, leisure and stress level. In conclusion, it was checked that the investiment in life quality programs offer benefits both to the staff and the enterprise which will account with good services and satisfaction of customer. Therefore, it was concluded that the laboral gymnastics while a ergonomic tool and a physical activity, it is an investiment which needs more and more to be strengthened and inserted by many segments of society
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
The reconfiguration of a distribution network is a change in its topology, aiming to provide specific operation conditions of the network, by changing the status of its switches. It can be performed regardless of any system anomaly. The service restoration is a particular case of reconfiguration and should be performed whenever there is a network failure or whenever one or more sections of a feeder have been taken out of service for maintenance. In such cases, loads that are supplied through lines sections that are downstream of portions removed for maintenance may be supplied by the closing of switches to the others feeders. By classical methods of reconfiguration, several switches may be required beyond those used to perform the restoration service. This includes switching feeders in the same substation or for substations that do not have any direct connection to the faulted feeder. These operations can cause discomfort, losses and dissatisfaction among consumers, as well as a negative reputation for the energy company. The purpose of this thesis is to develop a heuristic for reconfiguration of a distribution network, upon the occurrence of a failure in this network, making the switching only for feeders directly involved in this specific failed segment, considering that the switching applied is related exclusively to the isolation of failed sections and bars, as well as to supply electricity to the islands generated by the condition, with significant reduction in the number of applications of load flows, due to the use of sensitivity parameters for determining voltages and currents estimated on bars and lines of the feeders directly involved with that failed segment. A comparison between this process and classical methods is performed for different test networks from the literature about networks reconfiguration
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Resumo:
This works presents a proposal to make automatic the identification of energy thefts in the meter systems through Fuzzy Logic and supervisory like SCADA. The solution we find by to collect datas from meters at customers units: voltage, current, power demand, angles conditions of phasors diagrams of voltages and currents, and taking these datas by fuzzy logic with expert knowledge into a fuzzy system. The parameters collected are computed by fuzzy logic, in engineering alghorithm, and the output shows to user if the customer researched may be consuming electrical energy without to pay for it, and these feedbacks have its own membership grades. The value of this solution is a need for reduce the losses that already sets more than twenty per cent. In such a way that it is an expert system that looks for decision make with assertivity, and it looks forward to find which problems there are on site and then it wont happen problems of relationship among the utility and the customer unit. The database of an electrical company was utilized and the datas from it were worked by the fuzzy proposal and algorithm developed and the result was confirmed