992 resultados para AC Biosusceptometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug delivery systems based on natural polysaccharides, such as chitosan (CS) and pectin (PC), rather than on synthetic polymers, have been widely studied. Some reasons for that are low toxicity and costs and high biodegradability of the formers. A multiparticulate system based on CS and PC was developed in our laboratories, including the addition of an enteric polymer, cellulose acetate phtalate (CAP). Such improvement promoted stronger gastric and enteric resistances, as assessed in vitro, making the systems more selective to enzymatic degradation in the colon. Although in vitro dissolution tests can simulate some properties concerning the gastrointestinal transit (GT), collaborating to characterize the systems behavior in the biological fluids, frequently they do not result in satisfactory in vitro/in vivo correlations. The objective of this work was to follow in vivo the GT of the particles developed by means of AC biosusceptometry (ACB), a non-invasive and of low cost methodology. The particles containing ferrite in powder form were prepared by complex coacervation using an ideal 3:1:1 mass ratio for PC:CS:CAP. The magnetic particles were administered to healthy volunteers by oral route. The GT was monitored by using multi-sensor ACB system and the signal acquisition was performed every IS min until the colonic region was reached. By means of ACB technique, it was possible to acquiring images generated by the magnetic particles within the whole gastrointestinal tract including the colonic region. Variable particles transit times were observed among the volunteers, but without interference on the mapping of the particles until the colonic region. The particles were able to produce magnetic field strong enough to generate signals adequate for mapping the particles. The results suggest that integral particles reached the colon, after they resisted against gastric and enteric media. Studies associating transit time and in vivo drug release are in development in order to confirm the efficiency of the systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosus-ceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of Tc-99m and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral administration of solid dosage forms is usually preferred in drug therapy. Conventional imaging methods are essential tools to investigate the in vivo performance of these formulations. The non-invasive technique of ac biosusceptometry has been introduced as an alternative in studies focusing on gastrointestinal motility and, more recently, to evaluate the behaviour of magnetic tablets in vivo. The aim of this work was to employ a multisensor ac biosusceptometer system to obtain magnetic images of disintegration of tablets in vitro and in the human stomach. The results showed that the transition between the magnetic marker and the magnetic tracer characterized the onset of disintegration (t(50)) and occurred in a short time interval (1.1 +/- 0.4 min). The multisensor ac biosusceptometer was reliable to monitor and analyse the in vivo performance of magnetic tablets showing accuracy to quantify disintegration through the magnetic images and to characterize the profile of this process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oral administration is a common route in the drug therapy and the solid pharmaceutical forms are widely used. Although much about the performance of these formulations can be learned from in vitro studies using conventional methods, evaluation in vivo is essential in product development. The knowledge of the gastrointestinal transit and how the physiological variables can interfere with the disintegration and drug absorption is a prerequisite for development of dosage forms. The aim of this work was to employing the ac biosusceptometry (ACB) to monitoring magnetic tablets in the human gastrointestinal tract and to obtain the magnetic images of the disintegration process in the colonic region. The ac biosusceptometry showed accuracy in the quantification of the gastric residence time, the intestinal transit time and the disintegration time (DT) of the magnetic formulations in the human gastrointestinal tract. Moreover, ac biosusceptometry is a non-invasive technique, radiation-free and harmless to the volunteers, as well as an important research tool in the pharmaceutical, pharmacological and physiological investigations. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To employ the AC Biosusceptometry (ACB) technique to evaluate in vitro and in vivo characteristics of enteric coated magnetic hydroxypropyl methylcellulose (HPMC) capsules and to image the disintegration process.Materials and Methods. HPMC capsules filled with ferrite (MnFe2O4) and coated with Eudragit (R) were evaluated using USP XXII method and administered to fasted volunteers. Single and multisensor ACB systems were used to characterize the gastrointestinal (GI) motility and to determine gastric residence time (GRT), small intestinal transit time (SITT) and orocaecal transit time (OCTT). Mean disintegration time (t (50)) was quantified from 50% increase of pixels in the imaging area.Results. In vitro and in vivo performance of the magnetic HPMC capsules as well as the disintegration process were monitored using ACB systems. The mean disintegration time (t (50)) calculated for in vitro was 25 +/- 5 min and for in vivo was 13 +/- 5 min. In vivo also were determined mean values for GRT (55 +/- 19 min), SITT (185 +/- 82 min) and OCTT (240 +/- 88 min).Conclusions. AC Biosusceptometry is a non-invasive technique originally proposed to monitoring pharmaceutical dosage forms orally administered and to image the disintegration process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mechanical nature of gastric contraction activity (GCA) plays an important role in gastrointestinal motility. The aim of this study was to detect GCA in anaesthetized dogs, using simultaneously the techniques of AC biosusceptometry (ACB) and manometry, analysing the characteristics of frequency and amplitude (motility index) of GCA, modified by drugs such as prostigmine and N-butyl-scopolamine. The ACB method is based on a differential transformer of magnetic flux and the magnetic tracer works as a changeable external nucleus. This magnetic tracer causes a modification in the magnetic flux, which is detected by the coils. The results obtained from the ACB showed a performance comparable to the manometry in measuring the modifications in the frequency and amplitude of the GCA. We concluded that this ACB technique, non-invasive and free of ionizing radiation, is an option for evaluating GCA and can be employed in future clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of physical phenomena that occurs during tablet disintegration has been studied by several experimental approaches; however none of them satisfactorily describe this process. The aim of this study was to investigate the influence of compression force on the tablets by associating the AC Biosusceptometry with consolidated methods in order to validate the biomagnetic technique as a tool for quality control in pharmaceutical processes.Tablets obtained at five compression levels were submitted to mechanical properties tests. For uncoated tablets, water uptake and disintegration force measurements were performed in order to compare with magnetic data. For coated tablets, magnetic measurements were carried out to establish a relationship between physical parameters of the disintegration process. According to the results, differences between the compression levels were found for water uptake, force development and magnetic area variation measurements. ACB method was able to estimate the disintegration properties as well as the kinetics of disintegration process for uncoated and coated tablets. This study provided a new approach for in vitro investigation and validated this biomagnetic technique as a tool for quality control for pharmaceutical industry. Moreover, using ACB will also be possible to test these parameters in humans allowing to establish an in vitro/in vivo correlation (IVIVC). (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventionally, pharmaceutical substances are administered orally because the gastrointestinal tract possesses the appropriate features for drug absorption. Nevertheless, the gastrointestinal tract physiology is complex and influenced by many factors. These factors must be completely understood for the optimization of oral drug delivery systems. Although in vitro tests provide information about release and drug absorption profiles, in vivo studies are essential, due to the biological variability. Several techniques have been employed in an attempt to conveniently characterize the behavior of solid dosage forms in vivo. The noninvasive biomagnetic technique of alternate current biosusceptometry (ACB) has been used in studies focusing on gastrointestinal motility and, more recently, to evaluate the performance of magnetic dosage forms. This article will discuss the main characteristics of AC biosusceptometry and its applicability for determination of the relationship between the human gastrointestinal tract and orally administered pharmaceutical dosage forms. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biomagnetic technique called Alternate Current Biosusceptometry (ACB) is a proposal to evaluate a multiparticulate drug delivery system in the human gastrointestinal tract. Results show that ACB was able to quantify the gastrointestinal transit and spreading of the magnetic material and is an attractive tool for pharmaceutical research. © 2007.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We employed ACB to characterize Gastric Emptying Time (GET - T1/2) and Gastric Activity Contraction (GAC) in dogs after erythromycin administration. An erythromycin dose of 50 mg was infused, after 24 h of fasting. Without erythromycin administration, ACB recorded GET of 157.5 ± 13.6 min (mean ± SD) and GAC of 4.4 ± 0.5 cpm (cycles per minute). After erythromycin administration was measured a GET of 84.2 ± 19.7 min. GAC was measured before, during and after erythromycin administration and results were, respectively, 4.4 ± 0.5, 4.9 ± 0.6 and 4.2 ± 0.3 cpm. Erythromycin produced efficient prokinetic action in gastric emptying and increased gastric motility in dogs. © 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.