Ethanol consumption damages the prostate, and testosterone is known by anti-inflammatory role. The cytokines were investigated in the plasma and ventral prostate of UChB rats submitted or not to testosterone therapy by ELISA and Western blot, respectively. Additionally, inflammatory foci and mast cells were identified in the ventral prostate slides stained by hematoxylin and eosin and toluidine blue, respectively. Inflammatory foci were found in the ethanol-treated animals and absent after testosterone therapy. Plasma levels of IL-6 and IL-10 were not changed while TNFα and TFG-β1 were increased in the animals submitted testosterone therapy. Regarding to ventral prostate, IL-6 did not alter, while IL-10, TNFα, and TFG-β1 were increased after testosterone therapy. Ethanol increases NFR2 in addition to high number of intact and degranulated mast cell which were reduced after testosterone therapy. So, ethanol and testosterone differentially modulates the cytokines in the plasma and prostate.
Resumo:
A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5μm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).
Resumo:
Sickle cell disease (SCD) pathogenesis leads to recurrent vaso-occlusive and hemolytic processes, causing numerous clinical complications including renal damage. As vasoconstrictive mechanisms may be enhanced in SCD, due to endothelial dysfunction and vasoactive protein production, we aimed to determine whether the expression of proteins of the renin-angiotensin system (RAS) may be altered in an animal model of SCD. Plasma angiotensin II (Ang II) was measured in C57BL/6 (WT) mice and mice with SCD by ELISA, while quantitative PCR was used to compare the expressions of the genes encoding the angiotensin-II-receptors 1 and 2 (AT1R and AT2R) and the angiotensin-converting enzymes (ACE1 and ACE2) in the kidneys, hearts, livers and brains of mice. The effects of hydroxyurea (HU; 50-75mg/kg/day, 4weeks) treatment on these parameters were also determined. Plasma Ang II was significantly diminished in SCD mice, compared with WT mice, in association with decreased AT1R and ACE1 expressions in SCD mice kidneys. Treatment of SCD mice with HU reduced leukocyte and platelet counts and increased plasma Ang II to levels similar to those of WT mice. HU also increased AT1R and ACE2 gene expression in the kidney and heart. Results indicate an imbalanced RAS in an SCD mouse model; HU therapy may be able to restore some RAS parameters in these mice. Further investigations regarding Ang II production and the RAS in human SCD may be warranted, as such changes may reflect or contribute to renal damage and alterations in blood pressure.
Resumo:
Crotamine is one of the main constituents of the venom of the South American rattlesnake Crotalus durissus terrificus. Here we sought to investigate the inflammatory and toxicological effects induced by the intrahippocampal administration of crotamine isolated from Crotalus whole venom. Adult rats received an intrahippocampal infusion of crotamine or vehicle and were euthanized 24 h or 21 days after infusion. Plasma and brain tissue were collected for biochemical analysis. Complete blood count, creatinine, urea, glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), creatine-kinase (CK), creatine kinase-muscle B (CK-MB) and oxidative parameters (assessed by DNA damage and micronucleus frequency in leukocytes, lipid peroxidation and protein carbonyls in plasma and brain) were quantified. Unpaired and paired t-tests were used for comparisons between saline and crotamine groups, and within groups (24 h vs. 21 days), respectively. After 24 h crotamine infusion promoted an increase of urea, GOT, GPT, CK, and platelets values (p ≤ 0.01), while red blood cells, hematocrit and leukocytes values decreased (p ≤ 0.01). Additionally, 21 days after infusion crotamine group showed increased creatinine, leukocytes, TBARS (plasma and brain), carbonyl (plasma and brain) and micronucleus compared to the saline-group (p ≤ 0.01). Our findings show that crotamine infusion alter hematological parameters and cardiac markers, as well as oxidative parameters, not only in the brain, but also in the blood, indicating a systemic pro-inflammatory and toxicological activity. A further scientific attempt in terms of preserving the beneficial activity over toxicity is required.
Resumo:
Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the gold standard, and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture.
Resumo:
Since the last decade, the combined use of chemometrics and molecular spectroscopic techniques has become a new alternative for direct drug determination, without the need of physical separation. Among the new methodologies developed, the application of PARAFAC in the decomposition of spectrofluorimetric data should be highlighted. The first objective of this article is to describe the theoretical basis of PARAFAC. For this purpose, a discussion about the order of chemometric methods used in multivariate calibration and the development of multi-dimensional methods is presented first. The other objective of this article is to divulge for the Brazilian chemical community the potential of the combination PARAFAC/spectrofluorimetry for the determination of drugs in complex biological matrices. For this purpose, two applications aiming at determining, respectively, doxorrubicine and salicylate in human plasma are presented.
Resumo:
In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
Chromatography combined with several different detection systems is one of the more used and better performing analytical tools. Chromatography with tandem mass spectrometric detection gives highly selective and sensitive analyses and permits obtaining structural information about the analites and about their molar masses. Due to these characteristics, this analytical technique is very efficient when used to detect substances at trace levels in complex matrices. In this paper we review instrumental and technical aspects of chromatography-tandem mass spectrometry and the state of the art of the technique as it is applied to analysis of toxic substances in food.
Resumo:
An absolute method is described via mass spectrometry (MS) for the structural assignment of isomers within the class of methylpiperidines. The method explores both the unimolecular and bimolecular gas phase behavior of structurally diagnostic fragment ions (SDFI). For the methylpiperidnes, the isomeric 2-methyl, 3-methyl and 4-methyl 2-azabutadienyl cations are found to function as SDFI. These fragment ions are expected to be formed from all members within the class, to be stable and to retain the structural information of the precursor molecule, and to not interconvert into one another. To characterize these SDFI, both the collision induced dissociation (CID) in argon and bimolecular ion/molecule chemistry with ethyl vinyl ether were compared.
Resumo:
A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.
Resumo:
The post harvest cooling and/or freezing processes for horticultural products have been carried out with the objective of removing the heat from these products, allowing them a bigger period of conservation. Therefore, the knowledge of the physical properties that involve heat transference in the fig fruit Roxo de Valinhos is useful for calculating projects and systems of food engineering in general, as well as, for using in equations of thermodynamic mathematical models. The values of conductivity and thermal diffusivity of the whole fig fruit-rami index were determined, and from these values it was determined the value of the specific heat. For these determination it was used the transient method of the Line Heat Source. The results shown that the fig fruit has a thermal conductivity of 0.52 W m-1°C, thermal diffusivity of 1.56 x 10-7 m² s-1, pulp density of 815.6 kg m-3 and specific heat of 4.07 kJ kg-1 °C.
Resumo:
In this work the performance of a sugar cane chopped harvester was analysed when fed with two sugar cane mass flows, measuring the invisible losses, which are impossible to measure in the field, harvester sugar cane cleaning efficiency and air velocity on extractors exit. The trial was done under controlled conditions at Copersucar Technology Center in January 2000. The results showed that the flow of sugar cane through the harvester doesn't influence the magnitudes of total invisible losses and raw material cleaning efficiency. The mean air velocity on the primary extractors exit was 12.0 m s-1, and 9.2 m s-1 on the secondary extractor, with a coefficient of variation of 21%, indicating that the poor cleaning performance of the harvester could be related to air velocity difference inside the extractor. Analyzing the data collected in the trials, it was possible to conclude that invisible losses in sugar cane harvester were 10% and the cleaning efficiency was 87%.
Resumo:
Development of processing technology and equipments requires new methods and better quality of the processed product. In the continuous drying process, utilization of equipments that promotes an increment in the transfer coefficients becomes of the major interest. The use of vibrational energy has been recommended to the dispersed materials. Such method is based on the use of vibrational energy applied to disperse media. Thus, a literature review on the mass transfer and drying in vibro-fluidized beds was carried out, showing experimental results and mathematical modeling.
Resumo:
Two kinds of roasting cocoa system: conventional batch method in electrical oven, and by microwaves, in a continuous microwave rotary applicator (2450MHz), were compared with respect to viscosity. Cocoa was roasted in whole beans and in nibs. The variable used in the microwave treatment was the power density applied to the whole beans (254,45 to 290,80 Wh/kg) and to the nibs (227,27 to 262,23 Wh/kg), with a constant holding time of 10 minutes. The variable used in the conventional roasting process was the roasting time of the beans (40 to 44 min) and the nibs (34 to 38 min), with constant temperature in the jacket of electric oven (150°C). Viscosity was measured in a Brookfield rheometer (mod RV-DVIII) at 40°C. In general, the plastic viscosity of the microwaved samples was lower than that of the conventional roasted samples. Also the nibs showed lower viscosities than the whole beans when roasted in the electric oven. The viscosity of the samples roasted in the microwave oven was lower in the whole beans than in the nibs. The product was sensorially evaluated by three experts in cocoa flavour, and it was shown that the flavour of the microwave roasted products was similar to that of the conventionally roasted products, with the advantage of a reduction in process time.