9 resultados para Técnica de conservación de alimentos
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
The acceptability of nine commercial brazilian varietal white table wines (Riesling, Chardonnay and Gewürztraminer) was evaluated using sensory affective tests. The samples were assessed by 43 consumers of brazilian white wines using he nine-point structured hedonic scale. Judges were recruited based on their responses to a questionnary about consumer?s behavior towards white wines consumption. Subsequently, Analysis of Variance (ANOVA) with means comparision (Tukey test) and Internal Analysis of Preference Mapping (MDPREF) were performed on data. Analysis of Variance showed that two samples (a Riesling and a Gewürztraminer, both sweet table wines) had significantly (p < 0.05) higher acceptance means, around 7 in the hedonic scale. The least acceptance means (4,3) was obtained by a demi-sec Chardonnay wine and the other six samples achieved means around 5 in the hedonic scale, all of them either demi-sec or dry table wines. MDPREF confirmed the results showed by ANOVA showing that samples were segmented into two groups of preference. The first group was composed by 86% of consumers who prefered the sweet table wines (higher acceptance), converging to the region on the map where these samples were represented. Only 14% showed preference for the demi-sec and dry table wines, being represented on the region of the MDPREF where these samples were located. This study suggests that sweet table wines are prefered by Brazilian consumers, instead of dry or demi-sec table wines.
Resumo:
The aim of this work was to develop and to validate a methodology using HPLC for the simultaneous determination of folates and folic acid in foods. The limits of detection and the recovery rates for the vitamins in the certified reference materials were respectively 5 pg/mL and 94-108% for 5-MTHF, 7 pg/mL and 97-102% for THF, 30 pg/mL and 97.9-104% for 5-FTHF, 30 pg/mL and 95-107 for 10-FFA, 5 ng/mL and 97-102% for FA and 5 ng/mL and 98-103% for 10-MFA. Repeatability showed a coefficient of variation below 3.9% for all the vitamins. The proposed methodology was shown to be efficient when applied to different certified reference materials, namely pig's liver (BCR487), powdered milk (BCR421) and a vegetable mixture (BCR485).
Resumo:
Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.
Resumo:
Surfactin, a lipopeptide produced by strains of Bacillus subtilis, has been proved to be a suitable biosurfactant in several applications. For many years, it has been investigated mainly for oil recovery and environmental usage. Its chemical, technological and functional characteristics turn surfactin into an attractive compound for several utilizations. In this review we emphasize some aspects of surfactin as a new food ingredient and its potential pharmaceutical and health applications.
Resumo:
Chromatography combined with several different detection systems is one of the more used and better performing analytical tools. Chromatography with tandem mass spectrometric detection gives highly selective and sensitive analyses and permits obtaining structural information about the analites and about their molar masses. Due to these characteristics, this analytical technique is very efficient when used to detect substances at trace levels in complex matrices. In this paper we review instrumental and technical aspects of chromatography-tandem mass spectrometry and the state of the art of the technique as it is applied to analysis of toxic substances in food.
Resumo:
Usually, the concepts of the Sol-Gel technique are not applied in experimental chemistry courses. This work presents a feasible experiment for chemistry instruction, which involves the synthesis of luminescent materials - Zn2SiO4, with and without Mn2+ as a dopant - by the Sol-Gel technique. The obtained materials were analyzed by scanning electron microscopy, X-Ray diffraction, IR spectroscopy and luminescence measures by UV-vis spectroscopy. The results allow the students to confirm the luminescent properties of the zinc orthosilicate luminophores as well as the structural features expected from literature data.
Resumo:
The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.
Resumo:
Different brands and batches of brazilian regular and instant coffee were purchased in supermarkets of Campinas? city and analysed for caffeine content. The method used involved extraction with boiling water, clarification with saturated basic acetate and determination by high performance liquid cromatography. Analysis was carried out using a Model 6000 A solvent delivery system (Waters associates), and a Model 7125 sample injector system (Reodyne, Inc.) with a 5µl sample loop. The system was also equipped with a Waters Model M440 absorbance detector set at 254 nm. A Merck ODS 5µm column (15 cm x 4.6 mm i.d.) was used to separate the caffeine. The mobile phase was methanol:water (25:75, v/v). The caffeine content varied for different brands and types of coffee and according to the beverage preparation technique. Values in the range of 0.43 to 0.85 mg/ml and 0.61 to 0.82 mg/ml were determined in regular and instant coffee, respectively.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física