30 resultados para Reliable Computations
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
To determine the most adequate number and size of tissue microarray (TMA) cores for pleomorphic adenoma immunohistochemical studies. Eighty-two pleomorphic adenoma cases were distributed in 3 TMA blocks assembled in triplicate containing 1.0-, 2.0-, and 3.0-mm cores. Immunohistochemical analysis against cytokeratin 7, Ki67, p63, and CD34 were performed and subsequently evaluated with PixelCount, nuclear, and microvessel software applications. The 1.0-mm TMA presented lower results than 2.0- and 3.0-mm TMAs versus conventional whole section slides. Possibly because of an increased amount of stromal tissue, 3.0-mm cores presented a higher microvessel density. Comparing the results obtained with one, two, and three 2.0-mm cores, there was no difference between triplicate or duplicate TMAs and a single-core TMA. Considering the possible loss of cylinders during immunohistochemical reactions, 2.0-mm TMAs in duplicate are a more reliable approach for pleomorphic adenoma immunohistochemical study.
Resumo:
4
Resumo:
The present paper describes a novel, simple and reliable differential pulse voltammetric method for determining amitriptyline (AMT) in pharmaceutical formulations. It has been described for many authors that this antidepressant is electrochemically inactive at carbon electrodes. However, the procedure proposed herein consisted in electrochemically oxidizing AMT at an unmodified carbon nanotube paste electrode in the presence of 0.1 mol L(-1) sulfuric acid used as electrolyte. At such concentration, the acid facilitated the AMT electroxidation through one-electron transfer at 1.33 V vs. Ag/AgCl, as observed by the augmentation of peak current. Concerning optimized conditions (modulation time 5 ms, scan rate 90 mV s(-1), and pulse amplitude 120 mV) a linear calibration curve was constructed in the range of 0.0-30.0 μmol L(-1), with a correlation coefficient of 0.9991 and a limit of detection of 1.61 μmol L(-1). The procedure was successfully validated for intra- and inter-day precision and accuracy. Moreover, its feasibility was assessed through analysis of commercial pharmaceutical formulations and it has been compared to the UV-vis spectrophotometric method used as standard analytical technique recommended by the Brazilian Pharmacopoeia.
Resumo:
The purpose of this study was to assess the efficacy and reproducibility of the cytologic diagnosis of salivary gland tumors (SGTs) using fine-needle aspiration cytology (FNAC). The study aimed to determine diagnostic accuracy, sensitivity, and specificity and to evaluate the extent of interobserver agreement. We retrospectively evaluated SGTs from the files of the Division of Pathology at the Clinics Hospital of São Paulo and Piracicaba Dental School between 2000 and 2006. We performed cytohistologic correlation in 182 SGTs. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 94%, 100%, 100%, 100%, and 99%, respectively. The interobserver cytologic reproducibility showed significant statistical concordance (P < .0001). FNAC is an effective tool for performing a reliable preoperative diagnosis in SGTs and shows high diagnostic accuracy and consistent interobserver reproducibility. Further FNAC studies analyzing large samples of malignant SGTs and reactive salivary lesions are needed to confirm their accuracy.
Resumo:
Quantification of dermal exposure to pesticides in rural workers, used in risk assessment, can be performed with different techniques such as patches or whole body evaluation. However, the wide variety of methods can jeopardize the process by producing disparate results, depending on the principles in sample collection. A critical review was thus performed on the main techniques for quantifying dermal exposure, calling attention to this issue and the need to establish a single methodology for quantification of dermal exposure in rural workers. Such harmonization of different techniques should help achieve safer and healthier working conditions. Techniques that can provide reliable exposure data are an essential first step towards avoiding harm to workers' health.
Resumo:
Balsamic vinegar (BV) is a typical and valuable Italian product, worldwide appreciated thanks to its characteristic flavors and potential health benefits. Several studies have been conducted to assess physicochemical and microbial compositions of BV, as well as its beneficial properties. Due to highly-disseminated claims of antioxidant, antihypertensive and antiglycemic properties, BV is a known target for frauds and adulterations. For that matter, product authentication, certifying its origin (region or country) and thus the processing conditions, is becoming a growing concern. Striving for fraud reduction as well as quality and safety assurance, reliable analytical strategies to rapidly evaluate BV quality are very interesting, also from an economical point of view. This work employs silica plate laser desorption/ionization mass spectrometry (SP-LDI-MS) for fast chemical profiling of commercial BV samples with protected geographical indication (PGI) and identification of its adulterated samples with low-priced vinegars, namely apple, alcohol and red/white wines.
Resumo:
Corynebacterium species (spp.) are among the most frequently isolated pathogens associated with subclinical mastitis in dairy cows. However, simple, fast, and reliable methods for the identification of species of the genus Corynebacterium are not currently available. This study aimed to evaluate the usefulness of matrix-assisted laser desorption ionization/mass spectrometry (MALDI-TOF MS) for identifying Corynebacterium spp. isolated from the mammary glands of dairy cows. Corynebacterium spp. were isolated from milk samples via microbiological culture (n=180) and were analyzed by MALDI-TOF MS and 16S rRNA gene sequencing. Using MALDI-TOF MS methodology, 161 Corynebacterium spp. isolates (89.4%) were correctly identified at the species level, whereas 12 isolates (6.7%) were identified at the genus level. Most isolates that were identified at the species level with 16 S rRNA gene sequencing were identified as Corynebacterium bovis (n=156; 86.7%) were also identified as C. bovis with MALDI-TOF MS. Five Corynebacterium spp. isolates (2.8%) were not correctly identified at the species level with MALDI-TOF MS and 2 isolates (1.1%) were considered unidentified because despite having MALDI-TOF MS scores >2, only the genus level was correctly identified. Therefore, MALDI-TOF MS could serve as an alternative method for species-level diagnoses of bovine intramammary infections caused by Corynebacterium spp.
Resumo:
The genera Cochliomyia and Chrysomya contain both obligate and saprophagous flies, which allows the comparison of different feeding habits between closely related species. Among the different strategies for comparing these habits is the use of qPCR to investigate the expression levels of candidate genes involved in feeding behavior. To ensure an accurate measure of the levels of gene expression, it is necessary to normalize the amount of the target gene with the amount of a reference gene having a stable expression across the compared species. Since there is no universal gene that can be used as a reference in functional studies, candidate genes for qPCR data normalization were selected and validated in three Calliphoridae (Diptera) species, Cochliomyia hominivorax Coquerel, Cochliomyia macellaria Fabricius, and Chrysomya albiceps Wiedemann . The expression stability of six genes ( Actin, Gapdh, Rp49, Rps17, α -tubulin, and GstD1) was evaluated among species within the same life stage and between life stages within each species. The expression levels of Actin, Gapdh, and Rp49 were the most stable among the selected genes. These genes can be used as reliable reference genes for functional studies in Calliphoridae using similar experimental settings.
Resumo:
To assess the completeness and reliability of the Information System on Live Births (Sinasc) data. A cross-sectional analysis of the reliability and completeness of Sinasc's data was performed using a sample of Live Birth Certificate (LBC) from 2009, related to births from Campinas, Southeast Brazil. For data analysis, hospitals were grouped according to category of service (Unified National Health System, private or both), 600 LBCs were randomly selected and the data were collected in LBC-copies through mothers and newborns' hospital records and by telephone interviews. The completeness of LBCs was evaluated, calculating the percentage of blank fields, and the LBCs agreement comparing the originals with the copies was evaluated by Kappa and intraclass correlation coefficients. The percentage of completeness of LBCs ranged from 99.8%-100%. For the most items, the agreement was excellent. However, the agreement was acceptable for marital status, maternal education and newborn infants' race/color, low for prenatal visits and presence of birth defects, and very low for the number of deceased children. The results showed that the municipality Sinasc is reliable for most of the studied variables. Investments in training of the professionals are suggested in an attempt to improve system capacity to support planning and implementation of health activities for the benefit of maternal and child population.
Resumo:
During the last ten years, graphene oxide has been explored in many applications due to its remarkable electroconductivity, thermal properties and mobility of charge carriers, among other properties. As discussed in this review, the literature suggests that a total characterization of graphene oxide must be conducted because oxidation debris (synthesis impurities) present in the graphene oxides could act as a graphene oxide surfactant, stabilizing aqueous dispersions. It is also important to note that the structure models of graphene oxide need to be revisited because of significant implications for its chemical composition and its direct covalent functionalization. Another aspect that is discussed is the need to consider graphene oxide surface chemistry. The hemolysis assay is recommended as a reliable test for the preliminary assessment of graphene oxide toxicity, biocompatibility and cell membrane interaction. More recently, graphene oxide has been extensively explored for drug delivery applications. An important increase in research efforts in this emerging field is clearly represented by the hundreds of related publications per year, including some reviews. Many studies have been performed to explore the graphene oxide properties that enable it to deliver more than one activity simultaneously and to combine multidrug systems with photothermal therapy, indicating that graphene oxide is an attractive tool to overcome hurdles in cancer therapies. Some strategic aspects of the application of these materials in cancer treatment are also discussed. In vitro studies have indicated that graphene oxide can also promote stem cell adhesion, growth and differentiation, and this review discusses the recent and pertinent findings regarding graphene oxide as a valuable nanomaterial for stem cell research in medicine. The protein corona is a key concept in nanomedicine and nanotoxicology because it provides a biomolecular identity for nanomaterials in a biological environment. Understanding protein corona-nanomaterial interactions and their influence on cellular responses is a challenging task at the nanobiointerface. New aspects and developments in this area are discussed.
Resumo:
To evaluate p16(INK) (4a) immunoexpression in CIN1 lesions looking for differences between cases that progress to CIN2/3 maintain CIN1 diagnosis, or spontaneously regress. Seventy-four CIN1 biopsies were studied. In the follow-up, a second biopsy was performed and 28.7% showed no lesion (regression), 37.9% maintained CIN1, and 33.4% progressed to CIN2/3. Immunostaining for p16(INK) (4a) was performed in the first biopsy and it was considered positive when there was strong and diffuse staining of the basal and parabasal layers. Pearson's chi-square was used to compare the groups (p ≤ 0.05). The age of the patients was similar. There was no significant difference in p16(INK) (4a) immunoexpression in the groups, however, statistical analyses showed a significant association when only the progression and regression groups were compared (p = 0.042). Considering p16(INK) (4a) positivity and the progression to CIN2/3, the sensitivity, specificity, positive, and negative predictive values in our cohort were 45%, 75%, 47%, and 94%, respectively. We emphasize that CIN1 with p16(INK) (4a) staining was associated with lesion progression, but the sensitivity was not high. However, the negative predictive value was more reliable (94%) and p16(INK) (4a) may represent a useful biomarker that can identify CIN1 lesions that need particular attention, complementing morphology.
Resumo:
We review here the chemistry of reactive oxygen and nitrogen species, their biological sources and targets; particularly, biomolecules implicated in the redox balance of the human blood, and appraise the analytical methods available for their detection and quantification. Those biomolecules are represented by the enzymatic antioxidant defense machinery, whereas coadjutant reducing protection is provided by several low molecular weight molecules. Biomolecules can be injured by RONS yielding a large repertoire of oxidized products, some of which can be taken as biomarkers of oxidative damage. Their reliable determination is of utmost interest for their potentiality in diagnosis, prevention and treatment of maladies.
Resumo:
Analytical laboratories are expected to produce reliable results. Decision makers are guided in their actions (financial, legal and environmental) using analytical data provided by numerous laboratories. This work aimed to evaluate the analytical performance of Brazilian laboratories on producing trustworthy results. Nineteen laboratories, accredited and non-accredited ones, were contracted to analyze a USGS (United States Geological Survey) certified water sample for 17 chemical elements (mostly metals) without knowing the origin of the sample. Considering all the results produced, only 35% of them were valid. Three laboratories present satisfactory performances, whereas the majority showed a very poor overall performance. The outcomes of this work show the need for a more effective analytical quality program to Brazilian laboratories.
Resumo:
A simple analytical method for extraction and quantification of lutein colorant added to yogurt was developed and validated. The method allowed complete extraction of carotenoids using tetrahydrofuran in vortex, followed by centrifugation, partition to diethyl ether/petroleum ether, and drying. The carotenoids dissolved in ethanol were quantified by UV-Vis spectrophotometry. This method showed linearity in the range tested (1.41-13.42 µg g-1), limits of detection and quantification of 0.42 and 1.28 µg g-1, respectively, low relative standard deviation (3.4%) and recovery ranging from 95 to 103%. The method proved reliable for quantification of lutein added to yogurt.
Resumo:
Time Domain Reflectometry (TDR) is a reliable method for in-situ measurements of the humidity and the solution concentration at the same soil volume. Accurate interpretation of electrical conductivity (and soil humidity) measurements may require a specific calibration curve. The primary goal of this work was to establish a calibration procedure for using TDR to estimate potassium nitrate concentrations (KNO3) in soil solution. An equation relating the electrical conductivity measured by TDR and KNO3 concentration was established enabling the use of TDR technique to estimate soil water content and nitrate concentration for efficient fertigation management.