6 resultados para Placa de cortiça expandida
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Huntington disease (HD) is a progressive neurodegenerative disorder with autosomal dominant inheritance, characterized by choreiform movements and cognitive impairment. Onset of symptoms is around 40 years of age and progression to death occurs in approximately 10 to 15 years from the time of disease onset. HD is associated with an unstable CAG repeat expansion at the 5' and of the IT15 gene. We have genotyped the CAG repeat in the IT15 gene in 44 Brazilian individuals (42 patients and 2 unaffected family members) belonging to 34 unrelated families thought to segregate HD. We found one expanded CAG allele in 32 individuals (76%) belonging to 25 unrelated families. In these HD patients, expanded alleles varied from 43 to 73 CAG units and normal alleles varied from 18 to 26 CAGs. A significant negative correlation between age at onset of symptoms and size of the expanded CAG allele was found (r=0.6; p=0.0001); however, the size of the expanded CAG repeat could explain only about 40% of the variability in age at onset (r2=0.4). In addition, we genotyped 25 unrelated control individuals (total of 50 alleles) and found normal CAG repeats varying from 16 to 33 units. The percentage of heterozigocity of the normal allele in the control population was 88%. In conclusion, our results showed that not all patients with the HD phenotype carried the expansion at the IT15 gene. Furthermore, molecular diagnosis was possible in all individuals, since no alleles of intermediate size were found. Therefore, molecular confirmation of the clinical diagnosis in HD should be sought in all suspected patients, making it possible for adequate genetic counseling.
Resumo:
An alternative proposal for floor heating system by means of electric resistance for both chick and piggy installation is presented in this work. Several formulations of rice husk and cement mortar boards were used. An electronic device controlled all board temperature. This system presented a good efficiency design. The conventional cement mortar mixed with rice husk showed a better performance.
Resumo:
This work presents the development of low cost microprocessor-based equipment for generation of differential GPS correction signal, in real time, and configuration and supervision of the GPS base. The developed equipment contains a dedicated microcontroller connected to the GPS receiver, alphanumeric display and multifunction keyboard for configuration and operation of the system and communication interfaces. The electronic circuit has the function of receiving the information from GPS base; interpret them, converting the sentence in the RTCM SC-104 protocol. The microcontroller software makes the conversion of the signal received by the GPS base from the specific format to RTCM SC-104 protocol. The processing main board has two serials RS-232C standard interfaces. One of them is used for configuration and receiving the information generated by the GPS base. The other operates as output, sending the differential correction signal for the transmission system. The development of microprocessor-based equipment showed that it is possible the construction of a low cost private station for real time generation of differential GPS correction signal.
Resumo:
The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.
Resumo:
The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física