22 resultados para Determinação de minoxidil

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the last decade, the combined use of chemometrics and molecular spectroscopic techniques has become a new alternative for direct drug determination, without the need of physical separation. Among the new methodologies developed, the application of PARAFAC in the decomposition of spectrofluorimetric data should be highlighted. The first objective of this article is to describe the theoretical basis of PARAFAC. For this purpose, a discussion about the order of chemometric methods used in multivariate calibration and the development of multi-dimensional methods is presented first. The other objective of this article is to divulge for the Brazilian chemical community the potential of the combination PARAFAC/spectrofluorimetry for the determination of drugs in complex biological matrices. For this purpose, two applications aiming at determining, respectively, doxorrubicine and salicylate in human plasma are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adsorptive stripping voltammetry carried out in a homogeneous ternary solvent composed of N,N-dimethylformamide, water and ethanol, with alpha-benzoinoxime (alphaBO) as the complexing agent for Mo(VI) and a 0.5 mol L-1 acetic acid - sodium acetate buffer as supporting electrolyte was successfully used for the determination of molybdenum in polyvitamin-polymineral tablets. Tablet samples were analyzed and the results were compared with those obtained both by graphite furnace atomic absorption and by recovery tests, with good correlations, indicating that this may be considered as an alternative procedure for routine determination of Mo(VI) in pharmaceutical samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free fatty acids are a measure of evaluating fats and oils, submitted to abusive conditions, besides being a quality characteristic of edible vegetable oils. The official method of determination (AOCS Ca 5a-40, 2004) is based on titration, using phenolphthalein as an indicator. For crude and degummed oils, the titration end point is difficult to be observed due to the high level of pigments, resulting in dark solutions. In this case and others, such as self-life studies, in which sample quantities are limited, potentiometric titration may be a very good alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and to validate a methodology using HPLC for the simultaneous determination of folates and folic acid in foods. The limits of detection and the recovery rates for the vitamins in the certified reference materials were respectively 5 pg/mL and 94-108% for 5-MTHF, 7 pg/mL and 97-102% for THF, 30 pg/mL and 97.9-104% for 5-FTHF, 30 pg/mL and 95-107 for 10-FFA, 5 ng/mL and 97-102% for FA and 5 ng/mL and 98-103% for 10-MFA. Repeatability showed a coefficient of variation below 3.9% for all the vitamins. The proposed methodology was shown to be efficient when applied to different certified reference materials, namely pig's liver (BCR487), powdered milk (BCR421) and a vegetable mixture (BCR485).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Volatile compounds from green and roasted yerba mate were analyzed by gas chromatography/mass spectrometry and the flavor profile from yerba mate beverages was determined by descriptive quantitative analyses. The main compounds tentatively identified in green mate were linalool, alpha-terpineol and trans-linalool oxide and in roasted mate were (E,Z)-2,4-heptadienal isomers and 5-methylfurfural. Green mate infusion was qualified as having bitter taste and aroma as well as green grass aroma while roasted mate was defined as having a smooth, slightly burnt aroma. The relationship between the tentatively identified compounds and flavor must be determined by olfatometric analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review here the chemistry of reactive oxygen and nitrogen species, their biological sources and targets; particularly, biomolecules implicated in the redox balance of the human blood, and appraise the analytical methods available for their detection and quantification. Those biomolecules are represented by the enzymatic antioxidant defense machinery, whereas coadjutant reducing protection is provided by several low molecular weight molecules. Biomolecules can be injured by RONS yielding a large repertoire of oxidized products, some of which can be taken as biomarkers of oxidative damage. Their reliable determination is of utmost interest for their potentiality in diagnosis, prevention and treatment of maladies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical laboratories are expected to produce reliable results. Decision makers are guided in their actions (financial, legal and environmental) using analytical data provided by numerous laboratories. This work aimed to evaluate the analytical performance of Brazilian laboratories on producing trustworthy results. Nineteen laboratories, accredited and non-accredited ones, were contracted to analyze a USGS (United States Geological Survey) certified water sample for 17 chemical elements (mostly metals) without knowing the origin of the sample. Considering all the results produced, only 35% of them were valid. Three laboratories present satisfactory performances, whereas the majority showed a very poor overall performance. The outcomes of this work show the need for a more effective analytical quality program to Brazilian laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a methodology for spectrophotometric determination of hexamethylenetetramine (HMT) by using chromotropic acid in a phosphoric acid media employing a domestic microwave oven as a source of heating. The reddish-purple soluble product is quantitatively formed after 30 s of irradiation and obeys the Beer´s law in the range between 0.1-1.2 mg L-1 HMT (r = 0.99925). The method was applied successfully in commercial pharmaceutical preparations containing dyes in their composition. The results showed that the method proposed is feasible for simplicity, speed, low cost, precision and accuracy when compared with United States Pharmacopeia official method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gravimetric and electrochemical tests are the most common techniques used in determining the corrosion rate. However, the use of electrochemical polarization is limited to electrolytes with sufficient conductivity for which Tafel curves are linear. In this study, we investigated a technique in which working microelectrodes of AISI 1020 steel were used to obtain the Tafel curves in diesel oil. The strategy was to reduce the electrode area and hence the ohmic drop. The diameter of the microelectrode was reduced to a value where the compensation of the Tafel curves became unnecessary. The results showed that for electrodes with diameters below 50 μm, the ohmic drop tends to a minimum and independent of the microelectrode diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple analytical method for extraction and quantification of lutein colorant added to yogurt was developed and validated. The method allowed complete extraction of carotenoids using tetrahydrofuran in vortex, followed by centrifugation, partition to diethyl ether/petroleum ether, and drying. The carotenoids dissolved in ethanol were quantified by UV-Vis spectrophotometry. This method showed linearity in the range tested (1.41-13.42 µg g-1), limits of detection and quantification of 0.42 and 1.28 µg g-1, respectively, low relative standard deviation (3.4%) and recovery ranging from 95 to 103%. The method proved reliable for quantification of lutein added to yogurt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Companies worldwide are reviewing their working process to avoid waste, become aligned with environmental management standards and to fulfill specifications defined for national and international regulations. In this context, it is important that Brazilian Chemical companies have a specific stability guide for their products. The main purpose of this work is to present a stability guide for chemical products based on the existing guides of the Pharmaceutical and Cosmetics segments. Furthermore, this work proposes to offer an additional period of shelf life for chemical products, provided they meet certain prerequisites.