4 resultados para Andrada e Silva, José Bonifácio de (1763-1838) -- Portraits

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Guarana seeds have the highest caffeine concentration among plants accumulating purine alkaloids, but in contrast with coffee and tea, practically nothing is known about caffeine metabolism in this Amazonian plant. In this study, the levels of purine alkaloids in tissues of five guarana cultivars were determined. Theobromine was the main alkaloid that accumulated in leaves, stems, inflorescences and pericarps of fruit, while caffeine accumulated in the seeds and reached levels from 3.3% to 5.8%. In all tissues analysed, the alkaloid concentration, whether theobromine or caffeine, was higher in young/immature tissues, then decreasing with plant development/maturation. Caffeine synthase activity was highest in seeds of immature fruit. A nucleotide sequence (PcCS) was assembled with sequences retrieved from the EST database REALGENE using sequences of caffeine synthase from coffee and tea, whose expression was also highest in seeds from immature fruit. The PcCS has 1083bp and the protein sequence has greater similarity and identity with the caffeine synthase from cocoa (BTS1) and tea (TCS1). A recombinant PcCS allowed functional characterization of the enzyme as a bifunctional CS, able to catalyse the methylation of 7-methylxanthine to theobromine (3,7-dimethylxanthine), and theobromine to caffeine (1,3,7-trimethylxanthine), respectively. Among several substrates tested, PcCS showed higher affinity for theobromine, differing from all other caffeine synthases described so far, which have higher affinity for paraxanthine. When compared to previous knowledge on the protein structure of coffee caffeine synthase, the unique substrate affinity of PcCS is probably explained by the amino acid residues found in the active site of the predicted protein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few studies have evaluated the profile of use of disease modifying drugs (DMD) in Brazilian patients with spondyloarthritis (SpA). A common research protocol was applied prospectively in 1505 patients classified as SpA by criteria of the European Spondyloarthropathies Study Group (ESSG), followed at 29 referral centers in Rheumatology in Brazil. Demographic and clinical variables were obtained and evaluated, by analyzing their correlation with the use of DMDs methotrexate (MTX) and sulfasalazine (SSZ). At least one DMD was used by 73.6% of patients: MTX by 29.2% and SSZ by 21.7%, while 22.7% used both drugs. The use of MTX was significantly associated with peripheral involvement, and SSZ was associated with axial involvement, and the two drugs were more administered, separately or in combination, in the mixed involvement (p < 0.001). The use of a DMD was significantly associated with Caucasian ethnicity (MTX , p = 0.014), inflammatory back pain (SSZ, p = 0.002) , buttock pain (SSZ, p = 0.030), neck pain (MTX, p = 0.042), arthritis of the lower limbs (MTX, p < 0.001), arthritis of the upper limbs (MTX, p < 0.001), enthesitis (p = 0.007), dactylitis (MTX, p < 0.001), inflammatory bowel disease (SSZ, p < 0.001) and nail involvement (MTX, p < 0.001). The use of at least one DMD was reported by more than 70% of patients in a large cohort of Brazilian patients with SpA, with MTX use more associated with peripheral involvement and the use of SSZ more associated with axial involvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a contribution that presents a translation of the work Terminology for Analytical Capillary Electromigration Techniques by Riekkola and collaborators (Pure Appl. Chem., Vol. 76, No. 2, 443-451, 2004) from IUPAC© for the Portuguese Language. Additional terms that had not been defined in native Portuguese were included for the benefit of the local community. Additional notes were also included to clarify some important concepts and to highlight the differences between techniques.