716 resultados para Dunkeld, Bishops of.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this pilot study was to determine whether glugagon-like peptide 2 (GLP-2) secretion relates to insulin sensitivity (IS) in obese subjects. SUBJECTS AND METHODS: Twenty four obese subjects [body mass index (BMI) 40.0 ± 3.0 kg/m² (mean ± standard deviation)] were included, nine of which were male, age 43 ± 8 years. Twelve subjects had type 2 diabetes, all treated with oral anti-diabetic agents only. The subjects were submitted to standard meal tolerance test (MTT) for dosage of the curves: glucose, insulin, and GLP-2. Insulin sensitivity was measured by HOMA-IR, and OGIS was derived from the MTT. Spearman linear correlations and partial correlations were obtained. RESULTS: There was an inverse relationship between the GLP-2 secretion and IS: HOMA-IR correlated with GLP-2 AUC (R = 0.504; p = 0.012), and OGIS correlated with GLP-2 incremental AUC (R = -0.54; p = 0.054). The correlation persisted after controlling for BMI. CONCLUSION: We found an association of GLP-2 secretion and insulin resistance (IR). The understanding of the underlying mechanisms may provide future directions in the pharmacological manipulation of incretins, and in the treatment of obesity and related metabolic disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To establish the prevalence of refractive errors and ocular disorders in preschool and schoolchildren of Ibiporã, Brazil. Methods: A survey of 6 to 12-year-old children from public and private elementary schools was carried out in Ibiporã between 1989 and 1996. Visual acuity measurements were performed by trained teachers using Snellen's chart. Children with visual acuity <0.7 in at least one eye were referred to a complete ophthalmologic examination. Results: 35,936 visual acuity measurements were performed in 13,471 children. 1.966 children (14.59%) were referred to an ophthalmologic examination. Amblyopia was diagnosed in 237 children (1.76%), whereas strabismus was observed in 114 cases (0.84%). Cataract (n=17) (0.12%), chorioretinitis (n=38) (0.28%) and eyelid ptosis (n=6) (0.04%) were also diagnosed. Among the 614 (4.55%) children who were found to have refractive errors, 284 (46.25%) had hyperopia (hyperopia or hyperopic astigmatism), 206 (33.55%) had myopia (myopia or myopic astigmatism) and 124 (20.19%) showed mixed astigmatism. Conclusions: The study determined the local prevalence of amblyopia, refractive errors and eye disorders among preschool and schoolchildren.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the mean critical fusion frequency and the short-term fluctuation, to analyze the influence of age, gender, and the learning effect in healthy subjects undergoing flicker perimetry. METHODS: Study 1 - 95 healthy subjects underwent flicker perimetry once in one eye. Mean critical fusion frequency values were compared between genders, and the influence of age was evaluated using linear regression analysis. Study 2 - 20 healthy subjects underwent flicker perimetry 5 times in one eye. The first 3 sessions were separated by an interval of 1 to 30 days, whereas the last 3 sessions were performed within the same day. The first 3 sessions were used to investigate the presence of a learning effect, whereas the last 3 tests were used to calculate short-term fluctuation. RESULTS: Study 1 - Linear regression analysis demonstrated that mean global, foveal, central, and critical fusion frequency per quadrant significantly decreased with age (p<0.05).There were no statistically significant differences in mean critical fusion frequency values between males and females (p>0.05), with the exception of the central area and inferonasal quadrant (p=0.049 and p=0.011, respectively), where the values were lower in females. Study 2 - Mean global (p=0.014), central (p=0.008), and peripheral (p=0.03) critical fusion frequency were significantly lower in the first session compared to the second and third sessions. The mean global short-term fluctuation was 5.06±1.13 Hz, the mean interindividual and intraindividual variabilities were 11.2±2.8% and 6.4±1.5%, respectively. CONCLUSION: This study suggests that, in healthy subjects, critical fusion frequency decreases with age, that flicker perimetry is associated with a learning effect, and that a moderately high short-term fluctuation is expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to report a case of central retinal vein thrombosis associated with isolated heterozygous protein C deficiency. Acute occlusion of the central retinal vein presents as one of the most dramatic pictures in ophthalmology. It is often a result of both local and systemic causes. A rare systemic cause is heterozygous protein C deficiency, and it usually occurs in combination with other thrombophilic conditions. This case highlights that isolated heterozygous protein C deficiency may be the cause of central retinal vein thrombosis and underscores the importance of its screening in young patients with this ophthalmologic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the main success attitudes of young ophthalmologists in the first decade of their career. METHODS: This descriptive study comprised subjects selected from a sample of ophthalmologists who were participating in a congress, using a semi-structured questionnaire. The inclusion criteria were as follows: ophthalmologists under the age of 40 years, within 5-10 years from ophthalmology residency conclusion. The subjects were asked about the three main success attitudes in their personal experience during the first years of ophthalmology practice. After the initial results, the 10 most frequently mentioned attitudes were listed and volunteers were again interviewed to choose, within the latter list, the three main attitudes. RESULTS: Forty-eight ophthalmologists were interviewed, 24 (50%) were male; the mean age was 37 years (SD: 2 years, range: 33-40 years) and the mean time from ophthalmology residency conclusion was 8 years (SD: 1 year, range: 5-10 years). The frequency of such mentioned success attitudes were as follows: to invest in professional updating (22.9%), to have a good relationship with patients and professional partners (18.8%), to prioritize individual and family happiness (12.5%), initially to work in an established group (11.1%), to work in public service (9.7%), to have their own business with a homogeneous group (7.6%), to save money (7.6%), to be ready to resume work (4.2%), to get business administration skills (4.2%), and to have professional insurance (0.7%). CONCLUSIONS: The three main success attitudes consisted in investing in professional updating (22.9%), maintaining a good relationship with patients and professional partners (18.8%), and prioritizing individual and family happiness (12.5%). Although these results should not be generalized, they are helpful not only for those ophthalmologists at the beginning of a career but also those who want to reflect on what to prioritize in their professional practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare clinical trials published in Brazilian journals of ophthalmology and in foreign journals of ophthalmology with respect to the number of citations and the quality of reporting [by applying the Consolidated Standards for Reporting Trials (CONSORT) statement writing standards]. METHODS: The sample of this systematic review comprised the two Brazilian journals of ophthalmology indexed at Science Citation Index Expanded and six of the foreign journals of ophthalmology with highest Impact Factor® according ISI. All clinical trials (CTs) published from January 2009 to December 2010 at the Brazilians journals and a 1:1 randomized sample of the foreign journals were included. The primary outcome was the number of citations through the end of 2011. Subgroup analysis included language. The secondary outcome included likelihood of citation (cited at least once versus no citation), and presence or absence of CONSORT statement indicators. RESULTS: The citation counts were statistically significantly higher (P<0.001) in the Foreign Group (10.50) compared with the Brazilian Group (0.45). The likelihood citation was statistically significantly higher (P<0.001) in the Foreign Group (20/20 - 100%) compared with the Brazilian Group (8/20 - 40%). The subgroup analysis of the language influence in Brazilian articles showed that the citation counts were statistically significantly higher in the papers published in English (P<0.04). Of 37 possible CONSORT items, the mean for the Foreign Group was 20.55 and for the Brazilian Group was 13.65 (P<0.003). CONCLUSION: The number of citations and the quality of reporting of clinical trials in Brazilian journals of ophthalmology still are low when compared with the foreign journals of ophthalmology with highest Impact Factor®.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the association between language and number of citations of ophthalmology articles published in Brazilian journals. METHODS: This study was a systematic review. Original articles were identified by review of documents published at the two Brazilian ophthalmology journals indexed at Science Citation Index Expanded - SCIE [Arquivos Brasileiros de Oftalmologia (ABO) and Revista Brasileira de Oftalmologia (RBO)]. All document types (articles and reviews) listed at SCIE in English (English Group) or in Portuguese (Portuguese Group) from January 1, 2008 to December 31, 2009 were included, except: editorial materials; corrections; letters; and biographical items. The primary outcome was the number of citations through the end of second year after publication date. Subgroup analysis included likelihood of citation (cited at least once versus no citation), journal, and year of publication. RESULTS: The search at the web of science revealed 382 articles [107 (28%) in the English Group and 275 (72%) in the Portuguese Group]. Of those, 297 (77.7%) were published at the ABO and 85 (23.3%) at the RBO. The citation counts were statistically significantly higher (P<0.001) in the English Group (1.51 - SD 1.98 - range 0 to 11) compared with the Portuguese Group (0.57 - SD 1.06 - range 0 to 7). The likelihood citation was statistically significant higher (P<0.001) in the English Group (70/107 - 65.4%) compared with the Portuguese Group (89/275 - 32.7%). There were more articles published in English at the ABO (98/297 - 32.9%) than at the RBO (9/85 - 10.6%) [P<0.001]. There were no significant difference (P=0.967) at the proportion of articles published in English at the years 2008 (48/172 - 27.9%) and 2009 (59/210 - 28.1%). CONCLUSION: The number of citations of articles published in Portuguese at Brazilian ophthalmology journals is lower than the published in English. The results of this study suggest that the editorial boards should strongly encourage the authors to adopt English as the main language in their future articles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ocular surface toxicity of two nitric oxide donors in ex vivo and in vivo animal models: S-nitrosoglutathione (GSNO) and S-nitroso-N-acetylcysteine (SNAC) in a hydroxypropyl methylcellulose (HPMC) matrix at final concentrations 1.0 and 10.0 mM. METHODS: Ex vivo GSNO and SNAC toxicities were clinically and histologically analyzed using freshly excised pig eyeballs. In vivo experiments were performed with 20 albino rabbits which were randomized into 4 groups (5 animals each): Groups 1 and 2 received instillations of 150 µL of aqueous HPMC solution containing GSNO 1.0 and 10.0 mM, respectively, in one of the eyes; Groups 3 and 4 received instillations of 150 µL of aqueous HPMC solution-containing SNAC 1.0 and 10.0 mM, respectively, in one of the eyes. The contralateral eyes in each group received aqueous HPMC as a control. All animals underwent clinical evaluation on a slit lamp and the eyes were scored according to a modified Draize eye test and were histologically analyzed. RESULTS: Pig eyeballs showed no signs of perforation, erosion, corneal opacity or other gross damage. These findings were confirmed by histological analysis. There was no difference between control and treated rabbit eyes according to the Draize eye test score in all groups (p>0.05). All formulations showed a mean score under 1 and were classified as non-irritating. There was no evidence of tissue toxicity in the histological analysis in all animals. CONCLUSION: Aqueous HPMC solutions containing GSNO and SNAC at concentrations up to 10.0 mM do not induce ocular irritation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

134

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuronal ceroid-lipofuscinosis (NCL) is a recent term, proposed for acurate designation of the late-onset types of Amaurotic Family Idiocy (AFI). Histopathology shows ubiquitous intraneuronal accumulation of lipopigments, being the most important factor for characterization of the entity at present time. Biochemical changes and pathogenesis are obscure. NCL is in contrast to the infantile type of AFI (Tay-Sachs disease), in which intraneuronal accumulation of gangliosides (sphingolipids) is due to the well known deficiency of a lysosomal enzyme. The authors report on four cases of NCL, two brothers of the late infantile (Jansky-Bielschowsky) type and a brother and a sister of the juvenile (Spielmeyer-Sjögren) type. One autopsy and three cortical biopsies revealed moderate to severe distention of the neurons by lipopigment, with nerve cell loss, gliosis and cerebral atrophy. Lipopigment was also increased in liver, heart and spleen. The patients were the first in Brazilian literature in whom the storage material was identified as lipopigment by histochemical methods. A brief summary of the clinical features of NCL is presented, and relevant problems are discussed, concerning interpretation of the nature of the storage material, and significance of the disease for gerontological research.