Purpose: A survey was carried out on one hundred patients of the Emergency Service of the Ophthalmology Department of the Hospital das Clinicas of the University of Campinas (UNICAMP), in order to analyze the personal characteristics and the barriers against getting resolving ophthalmologic assistance. Variables, were the following: sex, age, home town, average distance between the place of initial symptoms and first visit to the hospital, time spent between the first examination (if performed in any other service) and the examination performed at the Hospital das Clinicas of University of Campinas, diagnosis, veracity of emergency, need to refer patients previously seen in other services to our Service and possibility of assistance and treatment at a secondary level. Methods: The sample showed the following characteristics: distances between 20 and 100 kilometers covered by 50.0% of the patients to be seen at University of Campinas. 75.0% of those patients needed someone to stay with them and 67.0% came from other municipalities. The long distances covered meant additional expenses for the treatment of diseases which should be treated locally. Results: Among the patients referred to University of Campinas by ophthalmologists of other services, 87.5% could have their diseases treated at a secondary level of assistance and 66.7% of real emergencies and 60% of false emergencies took longer than 7 days to reach the emergency room of University of Campinas. This shows the poor infrastructure of secondary services regarding excellence of emergency care and education of patients. Conclusions: We recommend education of general physicians and ophthalmologists for emergency eye care and also the supply of both secondary and tertiary public services or medicare, strategically setup in the whole state of Sao Paulo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the main causes of penetrating keratoplasty indications at Hospital das Clínicas-UNICAMP (January, 1999 to December, 2003). METHODS: A non-comparative, retrospective series of case studies. The authors reviewed the files of 857 patients who underwent penetrating keratoplasty at Hospital das Clínicas-UNICAMP between 1999-2003 and classified them into different categories according to diagnostic indication for surgery. RESULTS: The age range was between 0-88 years (average 44 years ±1.2). The main causes of penetrating keratoplasty were: keratoconus in 427 cases (49.82%); 152 cases (17.74%) of corneal ulceration (perforated or not); corneal graft failure in 87 cases (10.15%); bullous keratopathy, 72 cases (8.40%); Fuchs dystrophy in 59 cases (6.88%); trachoma complications in 28 cases (3.27%); other causes, 32 (3.74%). In children under 10 years of age, the main cause of penetrating keratoplasty indications was infectious ulcer (77.78%) and between 11-50 years of age, keratoconus was the main cause (71.65%). CONCLUSION: This study was composed of a young population, and the main causes of penetrating keratoplasty were keratoconus and therapeutic keratoplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is to report a case of central retinal vein thrombosis associated with isolated heterozygous protein C deficiency. Acute occlusion of the central retinal vein presents as one of the most dramatic pictures in ophthalmology. It is often a result of both local and systemic causes. A rare systemic cause is heterozygous protein C deficiency, and it usually occurs in combination with other thrombophilic conditions. This case highlights that isolated heterozygous protein C deficiency may be the cause of central retinal vein thrombosis and underscores the importance of its screening in young patients with this ophthalmologic disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the assistance quality through the perception of the users and municipal health managers (mayors, health secretaries and screening team). Methods: A transversal and descriptive study was carried out. Results: The sample was comprised by 359 users and 48 managers. Medical assistance was considered excellent by 79.6% of the users, 93.7% of the managers, 87.5% of the health secretaries and 100% of the screening team. Reception received a great evaluation by 73.8% of the users and 93.8% of the selectors. Conclusion: The assistance model used at the Ophthalmologic Clinic of Divinolândia obtained a high level of satisfaction pleasing both users and managers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física