22 resultados para SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION
Resumo:
The aim of this work was to develop and to validate a methodology using HPLC for the simultaneous determination of folates and folic acid in foods. The limits of detection and the recovery rates for the vitamins in the certified reference materials were respectively 5 pg/mL and 94-108% for 5-MTHF, 7 pg/mL and 97-102% for THF, 30 pg/mL and 97.9-104% for 5-FTHF, 30 pg/mL and 95-107 for 10-FFA, 5 ng/mL and 97-102% for FA and 5 ng/mL and 98-103% for 10-MFA. Repeatability showed a coefficient of variation below 3.9% for all the vitamins. The proposed methodology was shown to be efficient when applied to different certified reference materials, namely pig's liver (BCR487), powdered milk (BCR421) and a vegetable mixture (BCR485).
Resumo:
In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.
Resumo:
The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.
Resumo:
Dendrochemistry is based on the determination of elements retained in tree rings, which can be useful to characterize environmental occurrences. This work shows elemental mappings obtained by EDXRF of the cross section of a tree stem. The tree is originated from a polluted area in Campinas, São Paulo. Some profiles, as the sulfur one, show variations that can be attributed to external contributions, whereas the silicon one can be inferred to a protection defense natural mechanism. Besides being simultaneous and multielementar, the main advantages here are its performance through a non-destructive sample treatment and the ease of operation of XRF equipments.
Resumo:
This paper proposes a methodology to predict benzene uptake rate in ambient air, using passive samplers with Tenax TA. Variations in the uptake rate were found to occur as a function of the sampling time; and were greater at the beginning of sampling. An empirical model was obtained and values for uptake rate agree with literature. Concentration prediction errors can be minimized by using sampling times of 4 to 14 days, thus avoiding the influence of excessive uptake rates in the initial days and the influence of back diffusion at the end of the sampling period.
Resumo:
A simple analytical method for extraction and quantification of lutein colorant added to yogurt was developed and validated. The method allowed complete extraction of carotenoids using tetrahydrofuran in vortex, followed by centrifugation, partition to diethyl ether/petroleum ether, and drying. The carotenoids dissolved in ethanol were quantified by UV-Vis spectrophotometry. This method showed linearity in the range tested (1.41-13.42 µg g-1), limits of detection and quantification of 0.42 and 1.28 µg g-1, respectively, low relative standard deviation (3.4%) and recovery ranging from 95 to 103%. The method proved reliable for quantification of lutein added to yogurt.
Resumo: