39 resultados para Below-Knee Amputee


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gravimetric and electrochemical tests are the most common techniques used in determining the corrosion rate. However, the use of electrochemical polarization is limited to electrolytes with sufficient conductivity for which Tafel curves are linear. In this study, we investigated a technique in which working microelectrodes of AISI 1020 steel were used to obtain the Tafel curves in diesel oil. The strategy was to reduce the electrode area and hence the ohmic drop. The diameter of the microelectrode was reduced to a value where the compensation of the Tafel curves became unnecessary. The results showed that for electrodes with diameters below 50 μm, the ohmic drop tends to a minimum and independent of the microelectrode diameter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The creation of the Brazilian Program for the Modernization of the Horticulture by the Secretariat of Agriculture and Supplying of the State of São Paulo at CEAGESP, determined the standardization of fruit and vegetables in the follow aspects: degree of coloration, format, calibers, defects and packing. Therefore, the main goal of this research is to correlate the classification given by the Brazilian Program with the one used by the wholesalers at CEAGESP, verifying if the established norms are being fulfilled for cultivar Carmen and Debora (SAKATA SEED). The results showed, that for cultivar Carmem, for the averages of the observed values it does not move away from the norms created by the Program for sizes small and medium. However, for the case of cultivar Debora, the results showed differences between the adopted classifications. The tomatoes were devaluated, because had been commercialized below of the standardization indicated for the Brazilian Program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Swine production represents an important segment of Brazilian economy, and the possibility of increasing production is eminent mainly if considered the low pork consumption when compared to other meat and the consumption of other countries. The increasing need in the international market demands show that in a near future the commercial barriers will be based on welfare, in the protection of the environment as well as in the worker's legislation. Little knowledge is available in the subject of worker's standards in the environmental agents in rural activities as well as the air quality under Brazilian conditions. The objectives of this research were to apply the main used standards related to noise and gases and to estimate occupational risk using measurements of noise level, hydrogen sulfide, methane and oxygen in swine housing, in piglet's nursery and finishing. The results showed that the continuous noise level were below the one found in the standards, however there were observed differences (P < 0.05) in relation to the noise level measured in piglet's nursing cages and in semi-slatted floor. The respective concentrations of hydrogen sulfide and methane were less than 1 ppm and less than 0,1% by volume, which was lower than the recommended limits in NR-15, CIGR and ACGIH. The oxygen level was 21% in average.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brazil is an important poultry meat export country, and large parts of its destination are countries with specific rearing restrictions related to broiler s welfare. One of the aerial pollutants mostly found in high concentrations in closed poultry housing environment is ammonia. There are evidences that broilers welfare may be compromised by the continuous exposition to this pollutant in rearing housing. This research aimed to estimate broilers welfare reared under specific thermal environmental attributes and bird s density, as function of the ammonia concentration and light intensity inside the housing environment using the Fuzzy Theory. Results showed that the best welfare value (0.89 in the scale: 0-1) approximately 90% of the ideal was found in the conditions that associated the ideal thermal environment, with bird s density between 13-15 birds m-2, with values of the ammonia concentration in the environment below 5 ppm, and light intensity near 1 lx. Using the predictive method it was possible to estimate broilers welfare with relation to the ammonia concentration and light intensity in the housing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The swine breeder rearing environment directly affects the animal's performance. This research had the objective of developing a thermal, aerial and acoustic environmental evaluation pattern for boar housing. The experiment was carried on a commercial swine farm in Salto County -SP, Brazil. Thermal, aerial and acoustic environment data of rearing conditions were registered. Data were statistically analyzed using as threshold the ideal housing environment that leads to animal welfare. Results showed that ambient temperature was around 70% beyond normal range, while air relative humidity, air speed and gases concentration were within threshold values. Noise level data besides being within normal range did not present large variation. In relation to the fuzzy logic analysis it was possible to build up a scenario which indicated that the best welfare indexes to male swine breeders happens when thermal comfort index are close to 80%, and noise level is lower than 40 dB. In the other hand the worst welfare index occur in the sector where the thermal comfort values are below 40% at the same time that the noise level is higher than 80 dB leading to inadequate conditions to the animal, and may directly interfere in the reproduction system performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between quantitative ultrasonography at hand phalanges (QUS) and dual energy X-ray absorptiometry (DXA), and between these methods with food intake and history of bone fractures. SUBJECTS AND METHODS:After two years of follow up of 270 schoolchildren, 10 of them, who showed bone mass below - 2 SD in QUS, were included in the present study. Laboratory results and DXA data were analyzed. RESULTS: Bone mass evaluated by DXA at L1-L4 ranged from -2.8 to -1.1 SDS, and whole body bone mass, from -2.9 to -1.2 SDS. Three children had history of non-pathological bone fractures. Dietary assessment showed low intake of calcium in 10 cases, of phosphorus in 6, and of vitamin D in 8 cases. There were no differences among the cases of bone mass below-2 SD in any of the three used methods. There was no association between history of bone fractures and food intake, and between these evaluations and bone mass. CONCLUSION: In this small group of schoolchildren there was an association between the methods QUS and DXA. However, there was no association between bone mass and the history of bone fractures, or calcium, phosphorus and vitamin D intake.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física