146 resultados para thermal radiation

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A numerical procedure for solving the nongray radiative transfer equation (RTE) in two-dimensional cylindrical participating media is presented. Nongray effects are treated by using a narrow-band approach. Radiative emission from CO, CO2, H2O, CH4 and soot is considered. The solution procedure is applied to study radiative heat transfer in a premixed CH4-O2, laminar, flame. Temperature, soot and IR-active species molar fraction distributions are allowed to vary in the axial direction of the flame. From the obtained results it is possible to quantify the radiative loss in the flame, as well as the importance of soot radiation as compared to gaseous radiation. Since the solution procedure is developed for a two-dimensional cylindrical geometry, it can be applied to other combustion systems such as furnaces, internal combustion engines, liquid and solid propellant combustion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the effect of heat treatment and ultraviolet radiation (UV-C) in the prevention of chilling injury in mangoes cv. Tommy Atkins previously stored or not under injury condition after their transference to ambient condition. Fruits were divided into groups: two were hydrothermally treated (46.1 ºC/90 min; 55 ºC/5 min) and two were exposed to UV-C radiation (1.14 kJ m-2; 2.28 kJ m-2). These groups were stored under chilling injury conditions (5 ºC for 14 days), as established in preliminary tests. Other untreated groups were stored at 12 ºC or 5 ºC. After the storage period, they were transferred to ambient conditions (21.9 ºC; 55% RH) and the quality was evaluated. All the data were submitted to multivariate analysis as the tool to verify the simultaneous effect of the treatments under the quality parameters. The multivariate analysis indicated that the hydrothermal treatments at 46.1 °C/90 min and 55 °C/5 min and the UV-C radiation at doses of 1.14 kJ m-2 and 2.28 kJ m-2 were effective in minimized the symptoms of chilling injury in mangoes ‘Tommy Atkins’ stored at 5 °C for 14 days. However, after their transference to environmental condition at 21.9 °C, only the UV-C kept this control, especially at a dose of 2.28 kJ m-2. This treatment did not prevent the development of the characteristic color or affected the normal ripening and allowed the conservation of fruit for a period of 14 days at 5 °C, plus seven days of storage at environmental condition, which corresponds to the shipping transportation plus the time for sale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the building materials used in rural facilities, roofs are noteworthy for being largely responsible for thermal comfort, influencing the thermal balance within the shelter. This study aimed to evaluate the influence of roof on the Enthalpy (H), Thermal Load of Radiation (TLR), and Black Globe Temperature and Humidity Index (BGHI) in individual shelters for dairy calves. The design was completely randomized with three treatments: Z - zinc tile, AC - asbestos-cement tile and ACW - asbestos-cement tile painted white on the upper side. The averages were compared by the Scott Knott test at 1% probability. The results showed no statistical difference between treatments (P<0.01) and the external environment for H. For TLR, there was statistical difference among all treatments, where ACW showed the lowest TLR, 489.28 W m-2, followed by AC with 506.72 W m-2 and Z with the highest TLR, 523.55 W m-2. For BGHI, the lowest values were observed for ACW (76.8) and AC (77.4), differing significantly from Z, which obtained the highest value (81.6). The tiles with white paint on the upper side promoted the lowest TLR and the lowest BGHI, favoring the thermal environment in the shelter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermal louvers, using movable or rotating shutters over a radiating surface, have gained a wide acceptance as highly efficient devices for controlling the temperature of a spacecraft. This paper presents a detailed analysis of the performance of a rectangular thermal louver with movable blades. The radiative capacity of the louver, determined by its effective emittance, is calculated for different values of the blades opening angle. Experimental results obtained with a prototype of a spacecraft thermal louver show good agreement with the theoretical values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing need for starches with specific characteristics makes it important to study unconventional starches and their modifications in order to meet consumer demands. The aim of this work was to study physicochemical characteristics of native starch and phosphate starch of S. lycocarpum. Native starch was phosphated with sodium tripolyphosphate (5-11%) added with stirring. Chemical composition, morphology, density, binding ability to cold water, swelling power and solubility index, turbidity and syneresis, rheological and calorimetric properties were determined. Phosphorus was not detected in the native sample, but the phosphating process produced modified starches with phosphorus contents of 0.015, 0.092 and 0.397%, with the capacity of absorbing more water, either cold or hot. Rheological data showed the strong influence of phosphorus content on viscosity of phosphate starch, with lower pasting temperature and peak viscosity higher than those of native starch. Enthalpy was negatively correlated with the phosphorus content, requiring 9.7; 8.5; 8.1 and 6.4 kJ g-1 of energy for the transition from the amorphous to the crystalline state for the starch granules with phosphorus contents of 0; 0.015; 0.092 and 0.397%, respectively. Cluster analysis and principal component analysis showed that starches with 0.015 and 0.092% phosphorus have similar characteristics and are different from the others. Our results show that the characteristics of phosphate modified S. lycocarpum starch have optimal conditions to meet the demands of raw materials, which require greater consistency in stickiness, combined with low rates of retrogradation and syneresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the effect of growth reducer and nitrogen fertilization on morphological variables, SPAD index, radiation interception, and grain yield of three cultivars of wheat. The experimental design was a randomized block in factorial scheme 3x5x2, with three cultivars (Mestre, Iguaçú and Itaipú), five nitrogen doses (0, 40, 80, 120, 160 Kg ha-1), and application or no application of a growth reducer, with three replications. The following characteristics were evaluated: plant height, SPAD index, leaf area index (LAI), Global Radiation Interception (GRI) and grain yield. The Tukey test (p < 0.05) was used for the comparison between the means of cultivar and growth reducer factors, and for a regression analysis to evaluate N levels. Increasing the dose of nitrogen promotes an increase in LAI of plants of wheat crops differently among cultivars, which leads to a greater degree of global radiation interception. At doses higher or equal to 120 Kg ha-1 of nitrogen, there are significant differences in grain yield between treatments with and without the application of the growth reducer. The significant interaction between growth reducer and nitrogen dose, showed that applications of growth reducer increase the GRI at doses above and below 80 Kg ha-1 of nitrogen. Nitrogen rates of 138 and 109 Kg ha-1 are responsible for maximum grain yields of wheat, which is 4235 and 3787 Kg ha-1 with and without the use of growth reducer, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Present report demonstrates that repeated radiation of Schistosoma mansoni-infected Biomphalaria glabrata, totaling 15,000 rads, caused a sudden, albeit transient, suppression of cercarial shedding. Initially, sporocysts practically disappeared from the snail tissues. The more resistant developing cercariae presented nuclear clumping and vacuolation, before undergoing lysis. No host tissue reaction was evident at any time. Thirty-four days after the last irradiation, the snails resumed cercarial elimination. By that time numerous sporocysts and developing cercariae were detected, disseminated throughout snail tissues in a pattern similar to that of a highly malignant neoplasm, with no signs of host cellular reactions, which on the other hand were present in non-irradiated infected controls. The region of the ovo-testis was apparently destroyed after radiation, but returned to its normal appearance around 40 days after the last radiation. Ionizing radiation affected both host and parasite in S. mansoni-infected Biomphalaria glabrata, but the resulting impressive changes were soon reversed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rare case of thumb metastasis from small cell lung cancer is presented. The patient underwent local radiotherapy with complete palliation of symptoms. She died 4 months later with disseminated disease. Considerations about incidence, treatment, and physiopathology of this kind of dissemination are made. Conservative treatment of finger metastasis with radiation may be considered due to the poor outcome of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic radiation proctitis represents a challenging condition seen with increased frequency due to the common use of radiation for treatment of pelvic cancer. Hemorrhagic radiation proctitis represents the most feared complication of chronic radiation proctitis. There is no consensus for the management of this condition despite the great number of clinical approaches and techniques that have been employed. Rectal resection represents an available option although associated with high morbidity and risk of permanent colostomy. The effectiveness of nonoperative approaches remains far from desirable, and hemorrhagic recurrence represents a major drawback that leads to a need for consecutive therapeutic sessions and combination of techniques. We conducted a critical review of published reports regarding conservative management of hemorrhagic chronic radiation proctitis. Although prospective randomized trials about hemorrhagic radiation proctitis are still lacking, there is enough evidence to conclude that topical formalin therapy and an endoscopic approach delivering an argon plasma coagulation represent available options associated with elevated effectiveness for interruption of rectal bleeding in patients with chronic radiation proctitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention.Objective:To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated.Results:A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001).Conclusion:Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.