Thermal comfort indices in individual shelters for dairy calves with different types of roofs
Data(s) |
01/12/2011
|
---|---|
Resumo |
Among the building materials used in rural facilities, roofs are noteworthy for being largely responsible for thermal comfort, influencing the thermal balance within the shelter. This study aimed to evaluate the influence of roof on the Enthalpy (H), Thermal Load of Radiation (TLR), and Black Globe Temperature and Humidity Index (BGHI) in individual shelters for dairy calves. The design was completely randomized with three treatments: Z - zinc tile, AC - asbestos-cement tile and ACW - asbestos-cement tile painted white on the upper side. The averages were compared by the Scott Knott test at 1% probability. The results showed no statistical difference between treatments (P<0.01) and the external environment for H. For TLR, there was statistical difference among all treatments, where ACW showed the lowest TLR, 489.28 W m-2, followed by AC with 506.72 W m-2 and Z with the highest TLR, 523.55 W m-2. For BGHI, the lowest values were observed for ACW (76.8) and AC (77.4), differing significantly from Z, which obtained the highest value (81.6). The tiles with white paint on the upper side promoted the lowest TLR and the lowest BGHI, favoring the thermal environment in the shelter. |
Formato |
text/html |
Identificador |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162011000600002 |
Idioma(s) |
en |
Publicador |
Associação Brasileira de Engenharia Agrícola |
Fonte |
Engenharia Agrícola v.31 n.6 2011 |
Palavras-Chave | #thermal indices #construction materials and type of roof |
Tipo |
journal article |