29 resultados para prosthesis and implants
em Scielo Saúde Pública - SP
Resumo:
Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.
Resumo:
This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p < 0.05, OR = 4.3). The most common etiological agent was Candida albicans (37 isolates), with 23 (62.2%) in the denture group and 14 (37.8%) (control group). Among patients who presented clinical manifestations of oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.
Resumo:
The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .
Resumo:
The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.
Resumo:
For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.
Resumo:
OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .
Resumo:
OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.
Resumo:
An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
Resumo:
Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.
Resumo:
A method using HPLC-UV was developed and validated for the determination of etoposide incorporated into polycaprolactone implants. The method was carried out in isocratic mode using a C18 column (250 x 4.6 mm; 5 µm), at 25 ºC, with acetonitrile and acetic acid 4% (70:30) as mobile phase, a flow rate of 2 mL/min, and UV detection at 285 nm. The method was linear (r² > 0.99) over the range of 5 to 65 µg/mL, precise (RSD < 5%), accurate (recovery of 98.7%), robust, selective regarding excipient of the sample, and had a quantitation limit equal to 1.76 µg/mL. The validated method can be successfully employed for routine quality control analyses.
Resumo:
We evaluated the mechanical behavior of the repaired surfaces of defective articular cartilage in the intercondylar region of the rat femur after a hydrogel graft implant. The results were compared to those for the adjacent normal articular cartilage and for control surfaces where the defects remained empty. Hydrogel synthesized by blending poly(2-hydroxyethyl methacrylate) and poly(methyl methacrylate-co-acrylic acid) was implanted in male Wistar rats. The animals were divided into five groups with postoperative follow-up periods of 3, 5, 8, 12 and 16 weeks. Indentation tests were performed on the neoformed surfaces in the knee joint (with or without a hydrogel implant) and on adjacent articular cartilage in order to assess the mechanical properties of the newly formed surface. Kruskal-Wallis analysis indicated that the mechanical behavior of the neoformed surfaces was significantly different from that of normal cartilage. Histological analysis of the repaired defects showed that the hydrogel implant filled the defect with no signs of inflammation as it was well anchored to the surrounding tissues, resulting in a newly formed articular surface. In the case of empty control defects, osseous tissue grew inside the defects and fibrous tissue formed on the articular surface of the defects. The repaired surface of the hydrogel implant was more compliant than normal articular cartilage throughout the 16 weeks following the operation, whereas the fibrous tissue that formed postoperatively over the empty defect was stiffer than normal articular cartilage after 5 weeks. This stiffness started to decrease 16 weeks after the operation, probably due to tissue degeneration. Thus, from the biomechanical and histological point of view, the hydrogel implant improved the articular surface repair.
Resumo:
Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.
Resumo:
OBJECTIVE: To assess the association between oral health and hygiene practices and oral cancer. METHODS: Hospital-based case-control study in the metropolitan area of São Paulo, southeastern Brazil, from 1998 to 2002. A total 309 patients with squamous cell carcinoma of the mouth and the pharynx and 468 controls matched by sex and age were included in the study. Cases were recruited in seven reference hospitals and controls were selected in five out of the seven participating hospitals. Detailed information on smoking, alcohol consumption, schooling, oral health status and hygiene practices were obtained through interviews. Odds ratios (OR) and 95% confidence intervals (95% CI), adjusted by sex, age, schooling, smoking, alcohol consumption as well as the variables oral health status and hygiene practices were estimated using unconditional logistic regression analyses. RESULTS: The use of complete dental prosthesis was not associated with oral cancer but regular gum bleeding showed a strong association (OR 3.1; 95% CI 1.2-7.9). Those who never attended a dental visit were more likely to have oral cancer (OR 2.5; 95% CI 1.3-4.8). Daily mouthwash use showed a stronger association to pharynx (OR 4.7; 95% CI 1.8-12.5) than mouth cancer (OR 3.2; 95% CI 1.6-6.3). CONCLUSIONS: Gum bleeding, no dental care, and daily mouthwash use were factors associated with oral cancer regardless of tobacco and alcohol consumption.
Resumo:
Aspergillosis is an infection caused by saprophytic fungi of the genus Aspergillus, which typically occurs in immunosuppressed individuals, but has also been reported in immunocompetent patients. The main routes of entry are the respiratory tract, skin, cornea, and ear, and the infection may be localized or disseminated by contiguity or vascular invasion. We report a severe case of rhinosinusitis with cutaneous involvement, caused by invasive aspergillosis, in an immunocompetent user of inhaled cocaine. Invasive aspergillosis related to cocaine abuse has not yet been reported in the literature. After itraconazole treatment and surgical debridement, complete clinical remission was achieved. Nasal reconstruction with a skin graft over a silicone prosthesis resulted in a satisfactory esthetic outcome.